Hostname: page-component-7b7567c8c-kwt9d Total loading time: 0 Render date: 2026-11-15T03:31:20.651Z Has data issue: false hasContentIssue false

Measurement of Mass Absorption Coefficients Using Compton-Scattered Cu Radiation in X-ray Diffraction Analysis

Published online by Cambridge University Press:  06 March 2019

Steve J. Chipera
Affiliation:
Earth & Environmental Sciences Division Los Alamos National Laboratory Mail Stop D469, Los Alamos, NM 87545
David L. Bish
Affiliation:
Earth & Environmental Sciences Division Los Alamos National Laboratory Mail Stop D469, Los Alamos, NM 87545
Get access

Abstract

The mass absorption coefficient is a useful parameter for quantitative characterization of materials. If the chemical composition of a sample is known, the mass absorption coefficient can be calculated directly. However, the mass absorption coefficient must be determined empirically if the chemical composition is unknown. Traditional methods for determining the mass absorption coefficient involve measuring the transmission of monochromatic X-rays through a sample of known thickness and density. Reynolds (1963,1967), however, proposed a method for determining the mass absorption coefficient by measuring the Compton or inelastic X-ray scattering from a sample using Mo radiation on an X-ray fluorescence spectrometer (XRF). With the recent advances in solid-state detectors/electronics for use with conventional powder diffractometers, it is now possible to readily determine mass absorption coefficients during routine X-ray diffraction (XRD) analyses.

Using Cu Kα radiation and Reynolds’ method on a Siemens D-500 diffractometer fitted with a Kevex Si(Li) solid-state detector, we have measured the mass absorption coefficients of a suite of minerals and pure chemical compounds ranging in μ/ρ from graphite to Fe-metal (μ/ρ = 4.6-308 using Cu Kα radiation) to ±4.0% (lσ). The relationship between the known mass absorption coefficient and the inverse count rate is linear with a correlation coefficient of 0.997. Using mass absorption coefficients, phase abundances can be determined during quantitative XRD analysis without requiring the use of an internal standard, even when an amorphous component is present.

Information

Type
VII. Solid State and Position-Sensitive Detectors for XRD
Copyright
Copyright © International Centre for Diffraction Data 1990

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable