Hostname: page-component-7b7567c8c-m6dxt Total loading time: 0 Render date: 2026-11-18T23:51:44.535Z Has data issue: false hasContentIssue false

Numerical simulation on the influence of aerothermodynamics on forward-facing cavities in hypersonic rarefied flow

Published online by Cambridge University Press:  17 June 2025

G. Gokul
Affiliation:
Department of Aerospace Engineering, SRM Institute of Science and Technology, Kattankulathur 603203, Chennai, Tamil Nadu, India
G. Malaikannan*
Affiliation:
Department of Aerospace Engineering, SRM Institute of Science and Technology, Kattankulathur 603203, Chennai, Tamil Nadu, India
*
Corresponding author: G. Malaikannan; Email: malaikag@srmist.edu.in
Rights & Permissions [Opens in a new window]

Abstract

The cavities over the re-entry vehicle alter the aerothermodynamic properties, leading to enhanced thermal protection as well as effective aerothermodynamic performance. This paper investigates the estimation of aerothermodynamic properties over a re-entry vehicle with different types of cavities on the frontal face of the vehicle. The direct simulation Monte Carlo (DSMC) simulation of hypersonic flow over the Crew module Atmospheric Re-entry Experiment (CARE) capsule was simulated with the re-entry velocity of 7,422 m/s and the freestream temperature of 225 K at an altitude of 110 km. A transient flow Knudsen number of 0.1 and air consists of 78.09% of ${N_2}$ and 21.91% of ${O_2}$ are used in the simulations. Two types of cavities, namely trapezoidal and the semi-circular cavity on the frontal face of the re-entry vehicle with different length to depth ratios, are analysed. The simulation results show that the recirculation regions are formed at the base of the cavity in the case of a cavity with sharp corners, whereas in the case of a cavity with rounded corners, the recirculation formed at the lip of the cavity for both trapezoidal and the semi-circular cavities. Increasing the length and depth of the cavity leads to smaller decrement in the drag when compared to the capsule without cavity for both trapezoidal and the semi-circular cavities. The heat flux is low for a cavity with the small L/D ratio (L/D = 0.5) for both fixed length and depth for trapezoidal-type cavity, whereas for large L/D ratio (L/D = 1.5) increasing the length of the cavity increases the overall heat flux.

Information

Type
Research Article
Copyright
© The Author(s), 2025. Published by Cambridge University Press on behalf of Royal Aeronautical Society
Figure 0

Table 1.Gas properties

Figure 1

Table 2.Freestream parameters

Figure 2

Figure 1.Grid independence study for heat transfer coefficient.

Figure 3

Figure 2.Time-step sensitivity analysis for heat transfer coefficient.

Figure 4

Figure 3.Validation plot for temperature along the stagnation streamline and the heat transfer coefficient along the surface of the cavity.

Figure 5

Figure 4.Validation plot for temperature along the stagnation streamline for flow over a sphere.

Figure 6

Figure 5.2D CAD model of re-entry capsules with and without cavity (all dimensions are in mm).

Figure 7

Figure 6.Velocity contour for C1-type cavity.

Figure 8

Figure 7.Velocity contour for C2-type cavity.

Figure 9

Figure 8.Velocity contour for C3-type cavity.

Figure 10

Figure 9.Velocity contour for C4-type cavity.

Figure 11

Figure 10.Velocity contour for C5-type cavity.

Figure 12

Figure 11.Velocity contour for C6-type cavity.

Figure 13

Figure 12.Velocity contour for C7-type cavity.

Figure 14

Figure 13.Velocity contour for C8-type cavity.

Figure 15

Figure 14.Velocity contour for C9-type cavity.

Figure 16

Figure 15.Velocity contour for C10-type cavity.

Figure 17

Figure 16.Comparison of velocity along the stagnation streamline of re-entry capsule with trapezoidal cavities.

Figure 18

Figure 17.Temperature contour of re-entry capsule with trapezoidal cavities.

Figure 19

Figure 18.Comparison of temperature along the stagnation streamline of re-entry capsule with trapezoidal cavities.

Figure 20

Figure 19.Comparison of pressure along the stagnation streamline of re-entry capsule with trapezoidal cavities.

Figure 21

Figure 20.Pressure contour of re-entry capsule with trapezoidal cavities.

Figure 22

Figure 21.Comparison of number density along the stagnation streamline over the re-entry capsule with trapezoidal cavity.

Figure 23

Figure 22.Comparison of drag coefficient over the re-entry capsule with trapezoidal cavity with sharp corner.

Figure 24

Figure 23.Comparison of drag coefficient over the re-entry capsule with trapezoidal cavity with rounded corner.

Figure 25

Figure 24.Comparison of heat tranfser coefficient over the re-entry capsule with trapezoidal cavity with sharp corner.

Figure 26

Figure 25.Comparison of heat transfer coefficient over the re-entry capsule with trapezoidal cavity with rounded corner.

Figure 27

Figure 26.Comparison of skin friction coefficient over the re-entry capsule with trapezoidal cavity with sharp corner.

Figure 28

Figure 27.Comparison of skin friction coefficient over the re-entry capsule with trapezoidal cavity with rounded corner.

Figure 29

Table 3.Comparison of drag and overall heat flux for all types of cavities

Figure 30

Figure 28.Velocity contour for C11-type cavity.

Figure 31

Figure 29.Velocity contour for C12-type cavity.

Figure 32

Figure 30.Velocity contour for C13-type cavity.

Figure 33

Figure 31.Velocity contour for C14 type cavity.

Figure 34

Figure 32.Comparison of velocity along the stagnation streamline of re-entry capsule with semicircular cavities.

Figure 35

Figure 33.Temperature contour for the re-entry capsule with semicircular cavities.

Figure 36

Figure 34.Comparison of temperature along the stagnation streamline of re-entry capsule with semicircular cavities.

Figure 37

Figure 35.Comparison of pressure along the stagnation streamline of re-entry capsule with semicircular cavities.

Figure 38

Figure 36.Pressure contour for the re-entry capsule with semicircular cavities.

Figure 39

Figure 37.Comparison of number density along the stagnation streamline over the re-entry capsule with semicircular cavity.

Figure 40

Figure 38.Comparison of drag coefficient over the re-entry capsule with semicircular cavity with sharp corner.

Figure 41

Figure 39.Comparison of drag coefficient over the re-entry capsule with semicircular cavity with rounded corner.

Figure 42

Figure 40.Comparison of heat transfer coefficient over the re-entry capsule over the re-entry capsule with semicircular cavity with sharp corner.

Figure 43

Figure 41.Comparison of heat transfer coefficient over the re-entry capsule with semicircular cavity with rounded corner.

Figure 44

Figure 42.Comparison of skin friction coefficient over the re-entry capsule with semicircular cavity with sharp corner.

Figure 45

Figure 43.Comparison of skin friction coefficient over the re-entry capsule with semicircular cavity with rounded corner.