Hostname: page-component-7b7567c8c-tnkh4 Total loading time: 0 Render date: 2026-11-16T11:23:37.302Z Has data issue: false hasContentIssue false

The use of a hand-held algometer as a method to measure mechanical nociceptive thresholds in sheep

Published online by Cambridge University Press:  01 January 2023

SM Stubsj⊘en*
Affiliation:
Norwegian School of Veterinary Science, Department of Production Animal Clinical Sciences, PO Box 8146, Dep NO-0033 Oslo, NorwayAnimalia, PO Box 396, Økern, NO-0513 Oslo, Norway
PS Valle
Affiliation:
Norwegian School of Veterinary Science, Department of Production Animal Clinical Sciences, PO Box 8146, Dep NO-0033 Oslo, NorwayMolde University College, PO Box 2110, NO-6402 Molde, Norway
AJ Zanella
Affiliation:
Norwegian School of Veterinary Science, Department of Production Animal Clinical Sciences, PO Box 8146, Dep NO-0033 Oslo, Norway
*
* Contact for correspondence and requests for reprints: solveigmarie.stubsjoen@nvh.no

Abstract

The aim of this study was to explore the use of a hand-held algometer for the measurement of mechanical nociceptive thresholds (MNT) in sheep (Ovis aries). Twelve ewes were tested over three consecutive days by two operators, and MNTs were measured over six predetermined sites on both forelimbs every five minutes for 30 min. The effects of test period, measurement number within test period and different anatomical points on MNT levels were investigated, in addition to establishing baseline MNT levels for the sheeps’ forelimbs. A significant decrease of MNT values was observed over the three consecutive test days and within each test period. The anatomical points located closest to the carpus and fetlock joints had significantly higher MNT values compared to the anatomical points located over the middle part of the metacarpus, possibly due to the protective function of the distal part of the extensor retinaculum and the dorsal pouch of the fetlock joint capsules. There was no difference in MNT values between the right and left foreleg. There was a tendency for a flattening out of the drop in MNT towards the last measurement. Hence, we suggest using the values from the last two measurements when determining normative values, and to habituate the ewes to the procedure of measuring MNT levels. Taking these factors into consideration, a hand-held algometer is a useful tool to measure MNTs in sheep.

Information

Type
Research Article
Copyright
© 2010 Universities Federation for Animal Welfare

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable