Hostname: page-component-7b7567c8c-fvjsw Total loading time: 0 Render date: 2026-11-14T21:49:13.439Z Has data issue: false hasContentIssue false

Process tomography of diffusion, using PET, to evaluate anisotropy and heterogeneity

Published online by Cambridge University Press:  02 January 2018

J. Kulenkampff*
Affiliation:
Helmholtz-Zentrum Dresden-Rossendorf, Permoserstr. 15, 04318 Leipzig, Germany
M. Gründig
Affiliation:
Helmholtz-Zentrum Dresden-Rossendorf, Permoserstr. 15, 04318 Leipzig, Germany
A. Zakhnini
Affiliation:
Helmholtz-Zentrum Dresden-Rossendorf, Permoserstr. 15, 04318 Leipzig, Germany
R. Gerasch
Affiliation:
Helmholtz-Zentrum Dresden-Rossendorf, Permoserstr. 15, 04318 Leipzig, Germany
J. Lippmann-Pipke
Affiliation:
Helmholtz-Zentrum Dresden-Rossendorf, Permoserstr. 15, 04318 Leipzig, Germany
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the 'Save PDF' action button.

Anisotropy and compositional and structural heterogeneity in clays are causes of considerable deviations from homogeneous diffusion, in particular in terms of direction-dependent transport rates and preferred transport zones. Conventional diffusion experiments, in which the sample is treated as a homogeneous black box in a concentration gradient, are interminable and insensitive to spatial effects. In contrast, tomographic imaging methods are capable of both reducing the amount of observation time required and revealing space-dependent features of the diffusion process.

In the present study, positron-emission-tomography (PET) was applied as the most sensitive quantitative spatiotemporal tomographic modality for direct observation of positron-emitting radiotracers in opaque media at reasonable resolution (1 mm) on a laboratory scale (100 mm).

Geoscientific applications of PET, or GeoPET, have revealed anisotropic and heterogeneous effects in diffusion experiments that have been conducted on Opalinus clay samples of different sizes, as well as on other rock types. Applying the Comsol Optimization Module to 2D-image sections of the PET tomograms, effective parameter values were derived, thereby quantifying the anisotropic diffusion.

Information

Type
Research Article
Creative Commons
Creative Common License - CCCreative Common License - BY
Copyright © The Mineralogical Society of Great Britain and Ireland 2015 This is an Open Access article, distributed under the terms of the Creative Commons Attribution license. (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright
Copyright © The Mineralogical Society of Great Britain and Ireland 2015