Hostname: page-component-7b7567c8c-wxvwp Total loading time: 0 Render date: 2026-11-16T07:45:50.042Z Has data issue: false hasContentIssue false

Characterization of Microbially Fe(III)-Reduced Nontronite: Environmental Cell-Transmission Electron Microscopy Study

Published online by Cambridge University Press:  01 January 2024

Jin-wook Kim*
Affiliation:
Marine Geosciences Division, Naval Research Laboratory, Stennis Space Center, MS 39529, USA
Yoko Furukawa
Affiliation:
Marine Geosciences Division, Naval Research Laboratory, Stennis Space Center, MS 39529, USA
Tyrone L. Daulton
Affiliation:
Marine Geosciences Division, Naval Research Laboratory, Stennis Space Center, MS 39529, USA
Dawn Lavoie
Affiliation:
US Geological Survey, Reston, VA 20192, USA
Steven W. Newell
Affiliation:
Marine Geosciences Division, Naval Research Laboratory, Stennis Space Center, MS 39529, USA
*
*E-mail address of corresponding author: jkim@nrlssc.navy.mil
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the 'Save PDF' action button.

Microstructural changes induced by the microbial reduction of Fe(III) in nontronite by Shewanella oneidensis were studied using environmental cell (EC)-transmission electron microscopy (TEM), conventional TEM, and X-ray powder diffraction (XRD). Direct observations of clays by EC-TEM in their hydrated state allowed for the first time an accurate and unambiguous TEM measurement of basal layer spacings and the contraction of layer spacing caused by microbial effects, most likely those of Fe(III) reduction. Non-reduced and Fe(III)-reduced nontronite, observed by EC-TEM, exhibited fringes with mean d001 spacings of 1.50 nm (standard deviation, σ = 0.08 nm) and 1.26 nm (σ = 0.10 nm), respectively. In comparison, the same samples embedded with Nanoplast resin, sectioned by microtome, and observed using conventional TEM, displayed layer spacings of 1.0–1.1 nm (non-reduced) and 1.0 nm (reduced). The results from Nanoplast-embedded samples are typical of conventional TEM studies, which have measured nearly identical layer spacings regardless of Fe oxidation state. Following Fe(III) reduction, both EC- and conventional TEM showed an increase in the order of nontronite selected area electron diffraction patterns while the images exhibited fewer wavy fringes and fewer layer terminations. An increase in stacking order in reduced nontronite was also suggested by XRD measurements. In particular, the ratio of the valley to peak intensity (v/p) of the 1.7 nm basal 001 peak of ethylene glycolated nontronite was measured at 0.65 (non-reduced) and 0.85 (microbially reduced).

Information

Type
Research Article
Copyright
Copyright © 2003, The Clay Minerals Society