On the Volume Conservation of the Immersed Boundary Method

Published online by Cambridge University Press:  20 August 2015

Boyce E. Griffith*
Affiliation:
Leon H. Charney Division of Cardiology, New York University School of Medicine, 550 First Avenue, New York, New York 10016, USA
*
*Corresponding author.Email:boyce.griffith@nyumc.org
Get access

Abstract

The immersed boundary (IB) method is an approach to problems of fluid-structure interaction in which an elastic structure is immersed in a viscous incompressible fluid. The IB formulation of such problems uses a Lagrangian description of the structure and an Eulerian description of the fluid. It is well known that some versions of the IB method can suffer from poor volume conservation. Methods have been introduced to improve the volume-conservation properties of the IB method, but they either have been fairly specialized, or have used complex, nonstandard Eulerian finite-difference discretizations. In this paper, we use quasi-static and dynamic benchmark problems to investigate the effect of the choice of Eulerian discretization on the volume-conservation properties of a formally second-order accurate IB method. We consider both collocated and staggered-grid discretization methods. For the tests considered herein, the staggered-grid IB scheme generally yields at least a modest improvement in volume conservation when compared to cell-centered methods, and in many cases considered in this work, the spurious volume changes exhibited by the staggered-grid IB method are more than an order of magnitude smaller than those of the collocated schemes. We also compare the performance of cell-centered schemes that use either exact or approximate projection methods. We find that the volume-conservation properties of approximate projection IB methods depend strongly on the formulation of the projection method. When used with the IB method, we find that pressure-free approximate projection methods can yield extremely poor volume conservation, whereas pressure-increment approximate projection methods yield volume conservation that is nearly identical to that of a cell-centered exact projection method.

Information

Type
Research Article
Copyright
Copyright © Global Science Press Limited 2012

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable