Hostname: page-component-7b7567c8c-tnkh4 Total loading time: 0 Render date: 2026-11-19T02:58:10.544Z Has data issue: false hasContentIssue false

Evaluation of procedures for hygienic hand-disinfection: controlled parallel experiments on the Vienna test model

Published online by Cambridge University Press:  19 October 2009

M. L. Rotter
Affiliation:
Institute of Hygiene of the University, Vienna, Austria
W. Koller
Affiliation:
Institute of Hygiene of the University, Vienna, Austria
G. Wewalka
Affiliation:
Institute of Hygiene of the University, Vienna, Austria
H. P. Werner
Affiliation:
Institute of Hygiene of the University, Mainz, West Germany
G. A. J. Ayliffe
Affiliation:
Hospital Infection Research Laboratory, Dudley Road Hospital, Birmingham B18 7QH, UK
J. R. Babb
Affiliation:
Hospital Infection Research Laboratory, Dudley Road Hospital, Birmingham B18 7QH, UK
Rights & Permissions [Opens in a new window]

Summary

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the 'Save PDF' action button.

Controlled parallel experiments were performed on the Vienna test model for the evaluation of procedures for hygienic hand-disinfection in three laboratories (Vienna, Mainz, Birmingham). The degerming activity of four procedures, each taking 1 min, was assessed repeatedly and compared with that of a standard disinfection procedure (ST) using isopropanol 60 % (v/v). The mean log reductions (mean log RF) for each procedure were as follows: n−propanol 50% (v/v) 4·85 and 5·14 in Vienna (V) and Mainz (M) respectively, ethanol 70 % (v/v) + chlorhexidinegluconate 0·5% (w/v), 4·01 (V), 3·76 (M) and 4·00 in Birmingham (B). Washing procedures were less effective, mean log RF 's of 3·19 (V), 3·49 (M) and 3·04 (B) were obtained with povidone-iodine soap, and 2·91 (V), 3·37 (M) and 3·27 (B) with a liquid phenolic soap. Analysis of variance on the data from Vienna and Mainz revealed significant differences of means not only between procedures (‘preparations’) but also on repeat testing. To compensate for the influence of variables such as test subjects, laboratory and day, the Vienna test model provides a method of standardization by testing a ST in parallel with the test procedure (P).

Standardization of the results was obtained by pair-wise substraction, log . Analysis of variance on the resulting values demonstrated that comparability of the results between laboratories and on repeat testing was achieved. The relative variation of the measurements within the laboratories ranged from 0·9 to 4·2%. As assessed by power-analysis, a disinfection procedure will be detected as significantly (P= 0·1) inferior to the standard processes in 95 of 100 experiments if it produces a mean log RF that is at least 0·55–0·65 log units smaller than that of the standard.

Information

Type
Research Article
Copyright
Copyright © Cambridge University Press 1986