In two surveys of three commercial abattoirs a minimal apparatus method for making bacterial counts, the ‘loop-tile’ method, detected the same trends in bacterial numbers on beef carcasses as the ISO reference method applied to the same samples. Both methods showed the carcasses from one abattoir, that with an export licence, to carry consistently higher numbers of bacteria, and one of the four sites sampled on each carcass to be consistently dirtier than the other three.