Biological Sterilization Monitors: A Four-Year In-Use Evaluation of Two Systems

Published online by Cambridge University Press:  02 January 2015

Helen Rosen Kotilainen
Affiliation:
Infection Control Department and Division of Infectious Disease, Department of Medicine, University of Massachusetts Medical Center, Worcester, Massachusetts
Nelson M. Gantz*
Affiliation:
Infection Control Department and Division of Infectious Disease, Department of Medicine, University of Massachusetts Medical Center, Worcester, Massachusetts
*
Division of Infectious Disease, Department of Medicine, University of Massachusetts Medical Center, 55 Lake Avenue North, Worcester, MA 01605

Abstract

Biological monitors (BI) are considered to be the best monitor of the sterilization process yet false positives may result in recalls and quality assurance difficulties. To assess the frequency, type and reasons for questionable results, we undertook a 4-year in-use study of two commonly used BI types—spore strips (Spordi®) and a self-contained crushable ampule (Attest®)—for both steam and ethylene oxide (EO). After laboratory verification of time/kill ratios for a portion of each involved lot, 2 BI of each type were placed in test pack within a randomly selected load run at standard time and temperature. All resulting positive BI were subcultured. Steam cycle positives were uncommon (32/1,1710 positive Spordi, 1.9%; 20/1,710 positive Attest, 1.2%) and could be related to chamber temperature or steam quality. All of the 4 BI per load were positive in only three loads; physical monitors indicated gross malfunction. Five positive Spordi were due to either contaminants or a malfunctioning incubator. EO-related positives were more common (53/1,109 positive Spordi, 4.8%; 25/1,109 positive Attest, 2.3%). One-half of the Spordi tests became positive after 48 hours of incubation. Organisms other than B. subtilis were recovered from 49.1% of the positive tests (26/53). The Attest was remarkable for its lack of contamination; 1/25 was positive for Pseudomonas stutzeri only. More positives were observed during the winter months when relative humidity was below 20%. This finding was more commonly observed with the EO Attest. In summary, we found no significant difference in the performance of either BI. Subculturing of positives and maintenance of proper humidity during storage should be emphasized.

Information

Type
Original Articles
Copyright
Copyright © The Society for Healthcare Epidemiology of America 1985

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable