Hostname: page-component-7b7567c8c-m6dxt Total loading time: 0 Render date: 2026-11-19T07:00:30.272Z Has data issue: false hasContentIssue false

Impact of a Rigid, Puncture Resistant Container System Upon Needlestick Injuries

Published online by Cambridge University Press:  02 January 2015

Bruce S. Ribner*
Affiliation:
Department of Hospital Epidemiology and Infection Control, Hermann Hospital; Program in Infectious Diseases and Clinical Microbiology, University of Texas Medical School at Houston, Houston, Texas
Martha N. Landry
Affiliation:
Department of Hospital Epidemiology and Infection Control, Hermann Hospital; Program in Infectious Diseases and Clinical Microbiology, University of Texas Medical School at Houston, Houston, Texas
Gail L. Gholson
Affiliation:
Department of Hospital Epidemiology and Infection Control, Hermann Hospital; Program in Infectious Diseases and Clinical Microbiology, University of Texas Medical School at Houston, Houston, Texas
Lisa A. Linden
Affiliation:
Department of Hospital Epidemiology and Infection Control, Hermann Hospital; Program in Infectious Diseases and Clinical Microbiology, University of Texas Medical School at Houston, Houston, Texas
*
Department of Medicine, Veterans Administration Medical Center, Asheville, NC 28805

Abstract

Needlestick injuries in a 720-bed tertiary care hospital were analyzed before and after the introduction of a rigid, puncture resistant, needle disposal system. Following implementation of the system, disposal-related injuries decreased from 0.9 per 100 full-time equivalent employees/year to 0.3 per 100 full-time equivalent employees/year (p <.005). However, needlesticks associated with procedures (2.2 vs. 4.4 per 100 full-time equivalent employees/year, p <.0005), and those resulting from loose needles (0.5 vs. 1.9 per 100 full-time equivalent employees/year, p <.0005), increased. Injuries occurring during needle recapping or the carrying of needles were not significantly altered. Total needlestick injuries increased from 6.0 to 8.7 per 100 full-time equivalent employees/year (p <.0005).

We concluded that a rigid, puncture resistant, needle disposal system can reduce disposal-related needlestick injuries, but must also be perceived as convenient to impact substantially upon needlesticks associated with other activities.

Information

Type
Original Articles
Copyright
Copyright © The Society for Healthcare Epidemiology of America 1987

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable