Hostname: page-component-7b7567c8c-fvjsw Total loading time: 0 Render date: 2026-11-16T17:51:09.055Z Has data issue: false hasContentIssue false

Line scale measurement using image registration

Published online by Cambridge University Press:  07 November 2013

P.B. Costa*
Affiliation:
National Institute of Metrology, Quality and Technology (INMETRO), Av. Nossa Senhora das Graças 50, CEP 25250-020, Duque de Caxias-RJ, BrazilMechanical Engineering Post-Graduation Program, Universidade Federal Fluminense (UFF), Rua Passo da Patria 156, CEP 24210-240, Niterói-RJ, Brazil
A. Marques
Affiliation:
Mechanical Engineering Post-Graduation Program, Universidade Federal do Paraná (UFPR), Jardim das Américas, CEP 81531-990, Curitiba-PR, Brazil
F.O. Baldner
Affiliation:
National Institute of Metrology, Quality and Technology (INMETRO), Av. Nossa Senhora das Graças 50, CEP 25250-020, Duque de Caxias-RJ, BrazilMechanical Engineering Post-Graduation Program, Universidade Federal Fluminense (UFF), Rua Passo da Patria 156, CEP 24210-240, Niterói-RJ, Brazil
F.R. Leta
Affiliation:
Mechanical Engineering Post-Graduation Program, Universidade Federal Fluminense (UFF), Rua Passo da Patria 156, CEP 24210-240, Niterói-RJ, Brazil
*
⋆ Correspondence: pbcosta@inmetro.gov.br

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the 'Save PDF' action button.

Currently, most advances in dimensional metrology might be seen by the evolution of non-contact measurement (optical measurements), in order to provide traceability for different areas that needs to calibrate microscopes or optical measure machines. In a similar way, the use of image processing techniques for the measuring of objects has been the subject of recent studies in computer vision and image metrology. In the attempt to meet the requirements and demands for high accuracy dimensional metrology with image processing techniques, this work will present the application of the image registration technique for the measurement of line scales. In the conventional calibration, the scales are measured in pre-established points, generally in intervals of 10% of the total scale length. With this application, it becomes possible to provide results for all the scale marks quickly and automatically, whereas in the conventional method it would require more time and, thus, a higher cost for the fulfillment of this measurement.

Information

Type
Research Article
Copyright
© EDP Sciences 2013