Analytical solutions for mass transport in hydrodynamic focusing by considering different diffusivities for sample and sheath flows

Published online by Cambridge University Press:  14 January 2019

Arman Sadeghi*
Affiliation:
Department of Mechanical Engineering, University of Kurdistan, Sanandaj 66177-15175, Iran
*
†Email address for correspondence: a.sadeghi@eng.uok.ac.ir

Abstract

The fluid flow and mass transfer characteristics in two-dimensional hydrodynamic focusing are theoretically investigated by considering different physical properties for the sample and sheath flows. Adopting a single-domain formulation, which assigns the region variable physical properties, three-dimensional analytical solutions are obtained for species transport under hydrodynamically fully developed conditions. In addition, simplified analytical solutions are derived assuming a uniform velocity field appropriate to electrokinetic focusing. The results show that the normalized overall mean velocity is an increasing function of the height to width ratio and a decreasing function of the sheath to sample viscosity ratio. The dependence of this normalized mean velocity on the sheath to sample flow-rate ratio is, however, non-monotonic: it grows with the flow-rate ratio when the sample fluid is more viscous than the sheath fluid, whereas the opposite is true when the sheath fluid is more viscous. Moreover, although an increase in either the viscosity or flow-rate ratios results in creating a smaller value of the normalized focused width, varying the channel aspect ratio may lead to either thinner or thicker focused regions, depending on the viscosity ratio. The inspection of the mass transport characteristics reveals that only the viscosity ratio and the Péclet number can significantly alter the mixing length. Surprisingly, the minimum mixing length in the presence of significant axial diffusion is achieved for a single-phase flow. Finally, the dimensionless mixing length is reduced by increasing the Péclet number, although the changes are negligible when this parameter is above 10. This threshold is only true when the Péclet number is calculated based on the higher of the sample and sheath diffusion coefficients.

Information

Type
JFM Papers
Copyright
© 2019 Cambridge University Press 
Figure 0

Figure 1.Schematic of the hydrodynamic focusing device considered including the dimensions, the coordinate system, and a typical velocity profile. The fluid containing solutes, referred to as sample fluid, enters the main channel from the middle inlet with volumetric flow rate $Q_{S}$. The sheath streams enter the device from the side inlets with a flow rate of $Q_{Sh}/2$ each. The darkness of the shading denotes solute abundance, which is lower in two diffusion zones created at the sample–sheath interfaces.

Figure 1

Table 1.Typical ranges of the main governing parameters.

Figure 2

Table 2.Values of $u_{m}^{\ast }$ calculated using different numbers of terms included in the series at two different values of $\unicode[STIX]{x1D702}_{\unicode[STIX]{x1D707}}$ while keeping $\unicode[STIX]{x1D6FC}=F=1$.

Figure 3

Figure 2.Velocity distribution at different values of $\unicode[STIX]{x1D6FC}$ and $\unicode[STIX]{x1D702}_{\unicode[STIX]{x1D707}}$ while keeping $F=1$.

Figure 4

Figure 3.Dependence of $u_{m}^{\ast }$ on the dimensionless parameters governing the hydrodynamic characteristics. The arrows in parts (a) and (b) denote the direction of decrease in $\unicode[STIX]{x1D702}_{\unicode[STIX]{x1D707}}$ and $\unicode[STIX]{x1D6FC}$, respectively.

Figure 5

Figure 4.Dependence of $\unicode[STIX]{x1D714}$ on the dimensionless parameters governing the hydrodynamic characteristics. The arrow in part (b) denotes the direction of decrease in $\unicode[STIX]{x1D6FC}$.

Figure 6

Figure 5.Dependence of $u_{m,S}^{\ast }$ and $u_{m,Sh}^{\ast }$ on $\unicode[STIX]{x1D702}_{\unicode[STIX]{x1D707}}$ at different values of $\unicode[STIX]{x1D6FC}$ and $F$. The arrows denote the direction of decrease in $\unicode[STIX]{x1D6FC}$.

Figure 7

Figure 6.Comparison between the values of $\unicode[STIX]{x1D714}$ predicted in the present study and the available experimental data (Lee et al.2006; Tripathi et al.2014; Shivhare et al.2016).

Figure 8

Figure 7.Contours of dimensionless concentration for $\unicode[STIX]{x1D6FC}=0.5$, $\unicode[STIX]{x1D702}_{\unicode[STIX]{x1D707}}=1$, $F=1$ and $Pe=10$ from $x=0$ up to the axial position $x=2.168W$. The arrows show the orientation of the coordinate system.

Figure 9

Figure 8.Contours of dimensionless concentration at the horizontal centreplane for $\unicode[STIX]{x1D6FC}=0.5$, $F=1$ and $Pe=5$ from $x=0$ up to the axial position $x=4.5W$. The dashed lines show the locations of the sample–sheath interfaces.

Figure 10

Figure 9.Cross-sectional contours of $c^{\ast }$ at different values of $x^{\ast }$ and $\unicode[STIX]{x1D702}_{\unicode[STIX]{x1D707}}$ for $\unicode[STIX]{x1D6FC}=0.5$, $F=1$ and $Pe=5$. The dashed lines show the locations of the sample–sheath interfaces.

Figure 11

Figure 10.Plots of $c^{\ast }$ versus $z^{\ast }$ at the horizontal centreline for different values of $x^{\ast }$ and $\unicode[STIX]{x1D702}_{\unicode[STIX]{x1D707}}$ while keeping $\unicode[STIX]{x1D6FC}=0.5$, $F=1$, and $Pe=5$.

Figure 12

Figure 11.Axial dependence of $I_{dis}$ at different values of the governing parameters. The default parameters include $\unicode[STIX]{x1D6FC}=0.5$, $\unicode[STIX]{x1D702}_{\unicode[STIX]{x1D707}}=1$, $F=1$ and $Pe=5$. The symbols in part (d) show the results of the uniform velocity solution.

Figure 13

Figure 12.Axial dependence of $c_{m,Sh}^{\ast }$ at different values of $\unicode[STIX]{x1D702}_{\unicode[STIX]{x1D707}}$ for $\unicode[STIX]{x1D6FC}=0.5$ and $F=1$. Lines without symbols: $Pe=5$; lines with symbols: $Pe\rightarrow \infty$.