Hostname: page-component-7b7567c8c-7pwfn Total loading time: 0 Render date: 2026-11-16T12:55:24.961Z Has data issue: false hasContentIssue false

Inside rod induced horizontal capillary emptying

Published online by Cambridge University Press:  11 August 2021

Xinping Zhou*
Affiliation:
School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, PR China
Gang Zhang
Affiliation:
School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, PR ChinaDepartment of Mechanics, Huazhong University of Science and Technology, Wuhan 430074, PR China
Chengwei Zhu
Affiliation:
School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, PR ChinaDepartment of Mechanics, Huazhong University of Science and Technology, Wuhan 430074, PR China
Dongwen Tan
Affiliation:
School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, PR China
Chenyu Fu
Affiliation:
School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, PR China
*
† Email address for correspondence: xpzhou08@hust.edu.cn

Abstract

The removal of a liquid blockage from a tube is of importance in many processes. If the Bond number (which measures the relative size of the gravitational force by comparison with the surface tension force on the blockage plug) is large enough, then the tube will become non-occluding automatically. If not, then other measures are required to remove the blockage and the insertion of a rod is one such measure. We investigate this situation in a horizontal capillary in a downward gravity field. Theoretical results are obtained and compared with experiments. We observe that a rod insertion can cause a change from liquid plug to non-occlusion in a horizontal capillary. For uniform inner and outer contact angles, compared with the case without an inside rod, the maximum of the critical emptying line decreases significantly, but the minimum decreases a little only for a large enough value of the ratio of inner radius to outer radius (χ). We find that changing the contact angles of the inserted tube can significantly affect the non-occluding of the tube. The minimum of critical emptying line can be lowered clearly, and the minimum for a large enough value of χ is much lower than that reached for a circular tube. The insertion of a hydrophobic (hydrophilic) rod with a large enough radius can make the liquid emptying easier in a horizontal hydrophilic (hydrophobic) capillary. This provides an effective method of triggering drainage of a fluid from a capillary in applications such as optofluidics and microfluidics.

Information

Type
JFM Papers
Copyright
© The Author(s), 2021. Published by Cambridge University Press
Figure 0

Figure 1.(a) Schematic of rod insertion into a horizontal circular capillary leading to change of a long liquid droplet from a plug to non-occlusion in a downward gravity field; (b) a cross-section of the horizontal concentric annular tube of inner and outer radii Ri and Ro with gas–liquid interface $\varGamma$, total and liquid interiors $\varOmega$ and ${\varOmega^\ast }$, total and wetting inner perimeters ${\varSigma_i}$ and $\varSigma_i^\ast $, total and wetting outer perimeters ${\varSigma_o}$ and $\varSigma_o^\ast $ and inner and outer contact angles γi and γo.

Figure 1

Figure 2.Schematic of evolution of the 3-D interface (an oblique view) as the Bond number gradually increases and approaches the critical Bond number. The 3-D interfaces computed by Surface Evolver (Brakke 1992) are integrated in a horizontal concentric annular tube.

Figure 2

Figure 3.(a) Theoretical predictions for the ‘critical emptying lines’ (Boc(γ) where γo = γi = γ) for the open capillary (upper black line), and for the capillary χ = 0.5 with rod inserted (lower red line). Also shown are experimental results for a 6.79 mm diameter tube with rod inserted (P1) and for a 5.92 mm diameter tube with rod inserted (P2). Results are also presented for larger diameter capillaries again with inserted rods. The red circles indicate liquid non-occlusion and the red cross indicates that the liquid plug remains. Note that, as predicted by theory, the larger tube becomes non-occluding after rod insertion (see P1) whereas the smaller tube remains blocked (see P2). Panels (b) and (c) show photographs of the liquid plug or non-occlusion before and after rod insertion in the two cases P1 and P2.

Figure 3

Figure 4.Critical Bond numbers of a horizontal circular tube (χ = 0) and a horizontal concentric annular tube versus uniform contact angle γo = γi. The radius ratio of the concentric annular cylinder changes from 0.1 to 0.9. The triangles and the crosses denote the data calculated by (2.6) and those directly computed via Surface Evolver in 3-D mode, respectively, for γo = γi = 90°. The circles denote the kinks of the curves. The squares denote the representative points each corresponding to a cross-section of the part of the interface that extends to infinite length at the critical Bond number. Here, A0, B0, C0, D0 and E0 correspond to γo = γi = 10°, 50°, 90°, 130° and 170°, respectively, for the circular cylinder, while, A, B, C, D and E correspond to γo = γi = 10°, 50°, 90°, 130° and 170°, respectively, for the concentric annular cylinder with χ = 0.1.

Figure 4

Figure 5.Critical Bond number of a horizontal concentric annular tube for inner wall contact angle γi = 90° versus outer wall contact angle γo. The radius ratio of the concentric annular cylinder changes from 0.1 to 0.8. The circles denote the kinks of the curves. The squares denote the representative points each corresponding to a cross-section of the part of the interface that extends to infinite length at the critical Bond number. Here, A, B, C, D and E correspond to γo = 10°, 50°, 90°, 130° and 170°, respectively, for χ = 0.1.

Figure 5

Figure 6.Critical Bond number of a horizontal concentric annular tube for inner wall contact angles γi = (a) 60° (120°), (b) 30° (150°), (c) 5° (175°) and (d) 1° (179°) versus outer wall contact angle γo. The tick values outside the brackets on the horizontal axis correspond to the cases for γi = (a) 60°, (b) 30°, (c) 5° or (d) 1°, while those inside the brackets on the horizontal axis correspond to the cases for γi = (a) 120°, (b) 150°, (c) 175° or (d) 179°. In (a–c), different radius ratios from 0.1 to 0.8 are used and in (d) different radius ratios from 0.5 to 0.9 are used. The circles denote the kinks of the curves. The squares denote the representative points each corresponding to a cross-section of the part of the interface that extends to infinite length at the critical Bond number. Here, A, B, C, D and E on the upper (lower) row correspond to γo = 10° (170°), 50° (130°), 90° (90°), 130° (50°) and 170° (10°), respectively, for (a–c) χ = 0.1 and (d) χ = 0.9. In (a–d), the interfaces for A, B, C, D and E in the upper row are shown to be symmetrical to the interfaces for A, B, C, D and E in the lower row over the x axis, respectively.