Hostname: page-component-7b7567c8c-7pwfn Total loading time: 0 Render date: 2026-11-16T05:36:54.576Z Has data issue: false hasContentIssue false

Designing a buildable optimised stellarator to confine electron–positron plasmas

Published online by Cambridge University Press:  24 September 2026

Pedro Francisco Gil*
Affiliation:
Max-Planck-Institut für Plasmaphysik, Garching 85748, Germany
Jason Smoniewski
Affiliation:
Max-Planck Institute for Plasma Physics, Greifswald 17491, GermanyPlasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
Paul Huslage
Affiliation:
Max-Planck-Institut für Plasmaphysik, Garching 85748, Germany
Rogerio Jorge
Affiliation:
Department of Physics, University of Wisconsin-Madison, Madison, WI 53706, USA
Timo Thun
Affiliation:
Max-Planck Institute for Plasma Physics, Greifswald 17491, Germany
Elisa Buglione-Ceresa
Affiliation:
Max-Planck-Institut für Plasmaphysik, Garching 85748, Germany
Tristan Schuler
Affiliation:
SchulerTEC, Germany
Stefan Fingl
Affiliation:
Max-Planck-Institut für Plasmaphysik, Garching 85748, Germany
Grégoire-Hubert Ducas
Affiliation:
Department of Mechanical Engineering, McGill University, Montreal, QC 13 H3A 0B9, Canada
Eve Virginia Stenson
Affiliation:
Max-Planck-Institut für Plasmaphysik, Garching 85748, Germany
*
Corresponding author: Pedro Francisco Gil, pedro.gil@ipp.mpg.de

Abstract

In this paper, the design of the plasma equilibrium and superconducting coils for the electrons and positrons in an optimised stellarator electrons and positrons in an optimized stellarator (EPOS), experiment is presented. With newly developed stellarator optimisation tools, including single-stage and stochastic optimisation, as well as high-temperature superconductor strain, this work demonstrates that it is possible to achieve key metrics for the buildability and confinement properties of the device. In particular, satisfactory quality of quasisymmetry and stellarator robustness is designed, and engineering requirements are met for eight different candidates. A feasibility study is presented that optimises multiple candidates for different plasma major radii and coil currents, as well as the best EPOS candidate to date, named C4_R19.

Information

Type
Research Article
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2026. Published by Cambridge University Press
Figure 0

Table 1.Summary of the main physics parameters of EPOS.Table 1 long description.

Figure 1

Figure 1.Top view of the engineering design concept for EPOS coils, each coil is made of a double HTS winding pack (here shown as a single brown stack) and is supported in an individual stellarator frame shown here in different colours for three coils. The last closed flux surface is shown in red.

Figure 2

Figure 2.Left: injection concept for the EPOS stellarator, a single positron trajectory is plotted in red starting at a field strength of approximately 6 mT and then channelled by a stray field line originating from the WL coil. Right: the particles arrive at the E ×$\times$ B electrodes and experience a drift in the radial direction as well as multiple bounces (from additional bouncing plates) until it is finally injected into the three-dimensionally shaped field. The electrons are to be injected via an emitter.

Figure 3

Figure 3.Figure 3 long description.Left: diagram displaying the optimisation scheme for EPOS consisting of three main optimisation stages: first, a stage II optimisation is performed to find relatively accurate coils; followed by the stochastic single-stage method focused on improving the coil shapes and optimising the surface to balance physics and engineering constraints. Finally, stage II optimisation is required to refine the HTS strain and coil concavity. Top right: rendering of the EPOS configuration with LCFS and coils after the single-stage step, the heatmap corresponds to the field error ⟨B⋅n⟩/⟨B⟩$\langle B\boldsymbol{\cdot }n\rangle /\langle B \rangle$, note that its maximum value is purposely still relatively high so as to not end up early on the design process in a sharp local minimum. Bottom right: Boozer plot showing the quality of quasisymmetry of the fixed-boundary ‘cold-start surface’ used for the EPOS optimisation.

Figure 4

Figure 4.Top left: quasisymmetric error of the EPOS configurations plotted against the major radius for both the VMEC equilibrium and the QFM-generated one. Top right: squared Flux vs QS error for all configurations. Bottom left: iota profiles for all the EPOS candidates and the three most important rationales bounding the rotation transform values. Bottom right: quasisymmetric error radial profile for the EPOS configurations.

Figure 5

Figure 5.Figure 5 long description.Loss fraction of positrons at 5 eV versus time of the EPOS configurations with starting conditions at s = 0.05 (left), s = 0.5 (middle) and s = 0.9 (right). Here, we show that, in the worst case scenario with no cyclotron cooling, at 5 eV, we are able to keep almost 100 % of the particles after 2 s when starting the particles at the magnetic axis. This ratio reduces to approximately 60 % when starting at the outer boundary.

Figure 6

Figure 6.Left: minimal number of positrons required to reach a/λD⩾10$a/\lambda _{D} \geqslant 10$ for all the configurations as a function of the major radius and plotted for different temperatures (0.1, 1 and 5 eV). Right: volume taken by the vacuum field of all the configurations as a function of the major radius.

Figure 7

Figure 7.Figure 7 long description.Left: maximum HTS torsional and binormal strain of all the configurations presented. Top right: HTS binormal strain of all the coils of the C3_R16 configuration. Bottom right: HTS torsional strain of all the coils of the C3_R16 configuration.

Figure 8

Figure 8.Left: normal curvature profiles for all the coils of configuration C4_R19 and for coil 1 of configuration C3_R17 as an example of highly concave sections. Right: rendering of coil 1 of C3_R17 showing the concave section and of coil 1 of C4_R19 demonstrating that simple convex coils are achievable as well.

Figure 9

Figure 9.Robustness of the quasisymmetry versus coil perturbation amplitude for all the configurations. Here, the metric is the average deviation from quasisymmetry at a certain perturbation amplitude of the coils.

Figure 10

Figure 10.Figure 10 long description.Left: amplitude of two cost functions during the different optimisation stages for C4_R19: the squared flux and the departure from quasisymmetry. Right: Boozer plot at the LCFS for the C4_R19 configuration obtained from a VMEC equilibrium after optimising a QFM surface, note that the field maximum at 2.6 T corresponds to the amplitude on the inboard side of the stellarator.

Figure 11

Figure 11.Figure 11 long description.Poincaré cross-sections of the C4_R19 configuration at four different toroidal positions, comparison between the VMEC solution (red) and field line tracing (black) from the magnetic field generated by coils for different toroidal cross-sections, ϕ=[0,π/6,π/3,π/2,5π/6,π]$\phi = [0, {\pi }/{6}, {\pi }/{3}, {\pi }/{2}, {5\pi }/{6}, \pi ]$. No island chains are visible.

Figure 12

Figure 12.The EPOS C4_$\_$R19 configuration with coils and LCFS, the heatmap corresponds to the field error ⟨B⋅n⟩/⟨B⟩$ {\langle B\boldsymbol{\cdot }n\rangle }/{\langle B \rangle }$. The coils fulfil the engineering requirements and the equilibrium fulfils the physics requirements.

Figure 13

Figure 13.Loss fraction distribution for 128 perturbed EPOS C4_R19 configurations. Each count represents one EPOS stellarator where the coils have been randomly perturbed with 1 mm deviations. A thousand particles in the simulation are followed for 0.5 s with 1 eV each starting at the radial coordinate of s = 0.9.

Figure 14

Figure 14.Figure 14 long description.Quasisymmetric error as a function of the number of coils and of the coil to surface distance.

Figure 15

Figure 15.Simulated coil forces shown on the coil filaments expressed in Nm−1 on two EPOS candidates: C3_R16 (left) and C4_R19 (right), spatial dimensions are to scale, apparent discontinuities in the left plot are due to applying a common scale for both stellarators.

Figure 16

Figure 16.Figure 16 long description.Left: scatter plot showing the torsional strain versus the binormal strain, where the intensity shows the convexity of the coils of the EPOS large-scale scans. Right: squared flux versus the maximum measured coil strain of a configuration defined as the maximum of the binormal and the torsional strain together with the mean iota of each configuration as a heatmap.

Figure 17

Table 2.Main parameters of the C4_R19 configuration of EPOS, standing as the best candidate so far. *Note that coil-to-surface and coil-to-coil distance values consider already SIMSOPT finite-build modifications; however, these are still subject to variations depending on the final engineering design that accounts for finite CAD dimensions.Table 2 long description.

Figure 18

Figure 17.Figure 17 long description.Star plots summarising the relevant properties for the EPOS stellarator candidates with major radii 16 and 17 cm. For all the properties except for iota, the blue area should ideally be minimised.

Figure 19

Figure 18.Star plots summarising the relevant properties for the EPOS stellarator candidates with major radii 18 and 19 cm. For all the properties except for iota, the blue area should ideally be minimised.