Hostname: page-component-6898cfcb55-th4rj Total loading time: 0 Render date: 2026-11-11T10:39:02.768Z Has data issue: false hasContentIssue false

Dosimetric variations in calculation grid size in prostate VMAT: a dose-volume histogram analysis using the Gaussian error function

Published online by Cambridge University Press:  23 November 2017

James C. L. Chow*
Affiliation:
Radiation Medicine Program, Princess Margaret Cancer Centre, University Health Network, Toronto, CanadaDepartment of Radiation Oncology, University of Toronto, Toronto, Canada
Runqing Jiang
Affiliation:
Medical Physics Department, Grand River Regional Cancer Centre, Kitchener, CanadaDepartment of Physics, University of Waterloo, Waterloo, Canada
Daniel Markel
Affiliation:
Radiation Medicine Program, Princess Margaret Cancer Centre, University Health Network, Toronto, Canada
*
Correspondence to: Dr James Chow, Radiation Medicine Program, Princess Margaret Cancer Centre, University Health Network, Toronto, Canada ON M5G 2M9. Tel: 416 946 4501. Fax: 416 946 6566. E-mail: james.chow@rmp.uhn.ca
Rights & Permissions [Opens in a new window]

Abstract

Background

Varying the calculation grid size can change the results of dose-volume and radiobiological parameters in a treatment plan, and therefore has an impact on the treatment planning quality assurance.

Purpose

This study investigated the dosimetric influence of the calculation grid size variation in the prostate volumetric modulated arc therapy (VMAT) plan.

Methods and materials

Dose distributions of 10 prostate VMAT plans were acquired using calculation grid sizes of 1–5 mm. Dose-volume histogram (DVH) analysis was carried out to determine the dose-volume variation corresponding to the grid size change using the Gaussian error function (GEF). At the same time, dose-volume points, dose-volume parameters and radiobiological parameters were calculated based on DVHs of targets and organs at risk (OARs) for each grid size.

Results

Comparing percentage variations of GEF parameters between the planning target volume (PTV) and clinical target volume (CTV), GEF parameters of the PTV were found varied more significantly than the CTV. This resulted in larger variations of dose-volume (%ΔCI=40·02 versus 13·55%, %ΔHI=12·45 versus 2·93% and %ΔGI=0·22 versus 0·06%) and radiobiological parameters (%ΔTCP=0·61 versus 0·25% and %ΔEUD=2·11 versus 0·26%) of the PTV compared with CTV. For OARs, the rectal wall showed a larger dose-volume variation than the rectum. However, similar dose-volume variation due to grid size change was not found in the bladder, bladder wall and femur.

Conclusions

Knowing the dosimetric variation in this study is important to the radiotherapy staff in the quality assurance for the prostate VMAT planning.

Information

Type
Original Article
Copyright
© Cambridge University Press 2017 
Figure 0

Table 1Range of volume, mean volume, median volume and standard deviation (SD) of the targets and organs at risk (OARs) for the 10 prostate volumetric modulated arc therapy (VMAT) patients

Figure 1

Figure 1Average dose-volume histograms of the (a) planning target volume, and (b) clinical target volume (CTV) for different calculation grid sizes (1–5 mm) in the prostate volumetric modulated arc therapy plans. PTV=planning target volume.

Figure 2

Figure 2Average dose-volume histograms of the (a) rectum, (b) rectal wall, (c) bladder and (d) bladder wall for different calculation grid sizes (1–5 mm) in the prostate volumetric modulated arc therapy plans.

Figure 3

Figure 3Parameters c1 and c2 versus calculation grid size for the planning and clinical target volume (PTV and CTV) in the prostate volumetric modulated arc therapy plans.

Figure 4

Figure 4Parameters (a) a1 to a4, (b) b1 to b4 and (c) c1 to c4 for the rectum and rectal wall in the prostate volumetric modulated arc therapy plans.

Figure 5

Figure 5Parameters (a) a1 to a4, (b) b1 to b4 and (c) c1 to c4 for the bladder and bladder wall in the prostate volumetric modulated arc therapy plans.

Figure 6

Table 2Percentage variations of the Gaussian error function parameters for the planning target volume (PTV), clinical target volume (CTV), rectum, rectal wall, bladder, bladder wall, left femur and right femur

Figure 7

Table 3Percentage variations of the doses, dose-volume points, dose-volume parameters and radiobiological parameters for the planning target volume (PTV), clinical target volume (CTV), rectum, rectal wall, bladder, bladder wall, left femur and right femur