Hostname: page-component-7b7567c8c-fvjsw Total loading time: 0 Render date: 2026-11-16T11:46:40.039Z Has data issue: false hasContentIssue false

Performance of a pulsed ion beam with a renewable cryogenically cooled ion source

Published online by Cambridge University Press:  18 September 2008

T.J. Renk*
Affiliation:
Sandia National Laboratories, Albuquerque, New Mexico
G.A. Mann
Affiliation:
Sandia National Laboratories, Albuquerque, New Mexico
G.A. Torres
Affiliation:
Sandia National Laboratories, Albuquerque, New Mexico
*
Address correspondence and reprint request to: Timothy J. Renk, MS 1182, P.O. Box 5800, Sandia National Laboratories, Albuquerque, NM 87185-1182. E-mail: tjrenk@sandia.gov
Get access

Abstract

For operation of an ion source in an intense ion beam diode, it is desirable to form a localized and robust source of high purity. A cryogenically operated ion source has great promise, since the ions are formed from a condensed high-purity gas, which has been confined to a relatively thin ice layer on the anode surface. Previous experiments have established the principles of operation of such an ion source, but have been limited in repetitive duration due to the use of short-lived liquid He cooling of the anode surface. We detail here the successful development of a “Cryo-Diode” in which the cooling was achieved with a closed-cycle cryo-pump. This results in an ion source design that can potentially be operated for an indefinite duration. Time-of-flight measurements with Faraday cups indicate that the resultant ion beam is of high-purity, and composed of singly charged ions formed out of the gas frozen out on the anode surface.

Information

Type
Research Article
Copyright
Copyright © Cambridge University Press 2008

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable