Hostname: page-component-7b7567c8c-wxvwp Total loading time: 0 Render date: 2026-11-16T21:32:35.888Z Has data issue: false hasContentIssue false

Differential Resistance Analysis – a New Tool for Evaluation of Solid Oxide Fuel Cells Degradation

Published online by Cambridge University Press:  09 November 2017

Zdravko B. Stoynov
Affiliation:
Institute of Electrochemistry and Energy Systems - BAS, 10 Acad. G. Bonchev St., Sofia 1113, Bulgaria,
Daria E. Vladikova*
Affiliation:
Institute of Electrochemistry and Energy Systems - BAS, 10 Acad. G. Bonchev St., Sofia 1113, Bulgaria,
Blagoy G. Burdin
Affiliation:
Institute of Electrochemistry and Energy Systems - BAS, 10 Acad. G. Bonchev St., Sofia 1113, Bulgaria,
Jerome Laurencin
Affiliation:
Universite Grenoble Alpes – CEA/LITEN, 17 rue des Martyrs, 38054, Grenoble, France
Dario Montinaro
Affiliation:
SOLID power S.p.A, Viale Trento 117, 38017 Mezzolombardo, Italy
Arata Nakajo
Affiliation:
Institut de Genie Mecanique, Ecole Polytechnique Federale de Lausanne, 1015 Lausanne, Switzerland
Paolo Piccardo
Affiliation:
University of Genoa, Department of Chemistry and Industrial Chemistry, I-16146 Genoa, Italy
Alain Thorel
Affiliation:
Centre des Matériaux, MINES-ParisTech, PSL, UMR CNRS 7633 BP 87, France
Maxime Hubert
Affiliation:
Universite Grenoble Alpes – CEA/LITEN, 17 rue des Martyrs, 38054, Grenoble, France
Roberto Spotorno
Affiliation:
University of Genoa, Department of Chemistry and Industrial Chemistry, I-16146 Genoa, Italy
Anthony Chesnaud
Affiliation:
Centre des Matériaux, MINES-ParisTech, PSL, UMR CNRS 7633 BP 87, France
*
Get access

Abstract

Solid Oxide Fuel Cells (SOFCs) are a promising technology that can provide efficient and clean energy production. The general barriers hindering their market entry are durability, i.e. resistance to aging, and costs. In parallel to the deeper insight into the different degradation sources and improved understanding of ageing factors and their interactions, work towards higher accuracy for the assessment and monitoring of real-world fuel cell ageing in necessary. The requirements for operational stability formulate the parameter “degradation rate” (DR). Most often long term durability tests are performed at constant current load and the decrease of the voltage is used for its definition. In this work a new approach based on analysis of the volt-ampere characteristics, named Differential Resistance Analysis (DRA), is presented. It operates with the differential resistance, i.e. with the derivative of the voltage in respect to the current (dU/dI = Rd) which is more sensitive to small deviations and thus increases the sensitivity of the analysis. Two performance indicators are derived (Rd, min and ∆U*) with differing selectivity: ∆U* is more sensitive to activation losses and Rd, min - to transport hindrances. The application of the DRA is demonstrated on examples from measurements in fuel cell and in reverse (fuel cell/electrolyzer) mode, as well as on modeling data. The results show that the method is at least 10 times more sensitive to DR evaluation in comparison with the classical approach.