Hostname: page-component-7b7567c8c-fvjsw Total loading time: 0 Render date: 2026-11-16T12:44:23.064Z Has data issue: false hasContentIssue false

Corrosion Fatigue Tests of Micro-Sized Specimens

Published online by Cambridge University Press:  17 March 2011

Y. Mizutani
Affiliation:
Precision and Intelligence Laboratory, Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama 226-8503, Japan, ymizutani64@pi.titech.ac.jp
Y. Higo
Affiliation:
Precision and Intelligence Laboratory, Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama 226-8503, Japan
Y. Ichikawa
Affiliation:
Precision and Intelligence Laboratory, Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama 226-8503, Japan
A. Morita
Affiliation:
Precision and Intelligence Laboratory, Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama 226-8503, Japan
K. Takashima
Affiliation:
Precision and Intelligence Laboratory, Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama 226-8503, Japan
M.V. Swain
Affiliation:
Biomaterials Science Research Unit, University of Sydney, Australian Technology Park Eveleigh, NSW1490, Australia
Get access

Abstract

Corrosion fatigue properties of micro-sized materials are extremely important to design MEMS devices and micro-machines used in corrosive environments. However, there have been few studies that investigate corrosion fatigue properties of micro-sized materials. Thus, it is necessary to develop a corrosion fatigue test method for micro-sized materials. However, there are several difficulties in corrosion fatigue tests on micro-sized specimens. It is also necessary to clarify the problems for the method and to find their solutions. In this investigation, a corrosion fatigue test method for micro-sized specimens has been developed and corrosion fatigue tests for micro-sized Ni-P amorphous alloy specimens have been carried out in a 0.9% NaCl solution. Specimens of cantilever-beam-type with dimensions of 10 × 12 × 50 μm3 were prepared from a Ni-P amorphous thin film by focused ion beam machining. Corrosion fatigue tests on the micro-sized specimens were succeeded, and environmental effects on fatigue properties of micro-sized specimens were clearly observed. Several problems and solutions for the method were described.

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable