Hostname: page-component-7b7567c8c-2n9c9 Total loading time: 0 Render date: 2026-11-19T01:18:18.152Z Has data issue: false hasContentIssue false

Actinide Science with a Soft X-ray Scanning Transmission X-ray Microscope (STXM)

Published online by Cambridge University Press:  01 February 2011

Per-Anders Glans
Affiliation:
PAGlans@lbl.gov, Lawrence Berkeley National Laboratory, Chemical Sciences Division, Berkeley, California, United States
Geza Szigethy
Affiliation:
gszigeth@uci.edu, Lawrence Berkeley National Laboratory, Chemical Sciences Division, Berkeley, California, United States
Dustin Demoin
Affiliation:
dwdgxb@mail.mizzou.edu, Lawrence Berkeley National Laboratory, Chemical Sciences Division, Berkeley, California, United States
Tolek Tyliszczak
Affiliation:
tolek@lbl.gov, Lawrence Berkeley National Laboratory, Advanced Light Source Division, Berkeley, California, United States
Jide Xu
Affiliation:
Jide@berkeley.edu, University of California, Department of Chemistry, Berkeley, California, United States
Jinghua Guo
Affiliation:
JGuo@lbl.gov, Lawrence Berkeley National Laboratory, Advanced Light Source Division, Berkeley, California, United States
Kenneth N. Raymond
Affiliation:
raymond@socrates.berkeley.edu, Lawrence Berkeley National Laboratory, Chemical Sciences Division, Berkeley, California, United States
David K. Shuh
Affiliation:
DKShuh@lbl.gov, Lawrence Berkeley National Laboratory, Chemical Sciences Division, Berkeley, California, United States
Get access

Abstract

Soft x-ray scanning transmission x-ray microscope (STXM) spectromicroscopy has been developed and employed to investigate several aspects of actinide chemistry and materials science at the Advanced Light Source Molecular Environmental Science (ALS-MES) Beamline 11.0.2 STXM end station. The basic approach and fundamentals of STXM experiments for radioactive materials systems is discussed. Representative results from STXM spectromicroscopy investigations of a mixed phase uranium nitride, single crystals of Eu(III)[TREN(Me-3,2-HOPO)]3 2H2O and hydrated Pu2(III)(C2O4)3(6H2O) 3H2O complexes are presented. The STXM images and soft x-ray absorption spectra illustrate the capabilities and utility of soft x-ray STXM for providing information about actinide materials, especially the light element constituents. Lastly, new and future opportunities for actinide science utilizing soft x-ray STXM are discussed in light of the planned upgrades for the STXM end stations at the ALS.

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable