Evaluation on Defects of Er and Yb Implanted Al070Ga030As by Using Positron Annihilation Spectroscopy

Published online by Cambridge University Press:  01 February 2011

Tomoyuki Arai
Affiliation:
tomoarai@isc.meiji.ac.jp, Meiji Univ., Dept. of Science and Technology, 1-1-1 Higashi-Mita, Tama-ku, Kawasaki, Kanagawa, 214-8571, Japan, 81-44-934-7306, 81-44-934-7909
Shin-ichiro Uekusa
Affiliation:
uekusa@isc.meiji.ac.jp, Meiji University, Dept. of Science and Technology, Japan
Akira Uedono
Affiliation:
uedono@sakura.cc.tsukuba.ac.jp, Tsukuba University, Institute of Applied Physics, Japan
Get access

Abstract

The influence on defects of Er implanted Al0.70Ga0.30As was studied, using standard Positron Annihilation Spectroscopy (PAS) and Photoluminescence (PL) technique. The incident energy of mono-energetic positrons was implanted from 0.1 eV to 30 keV. The characterization of un-doped Al0.70Ga0.30As and Al0.70Ga0.30As:Er,Yb as implanted, and Al0.70Ga0.30As:Er,Yb annealed ranging from 500 to 900 °C were successfully studied by using PAS technique. Into the incident energy around 5keV, the shape parameter of Al0.70Ga0.30As:Er,Yb annealed ranging from 500 to 900 °C was decreased and the PL intensity also increased in response to the annealing temperature ranging from 500 to 900 °C.

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable