Hostname: page-component-7b7567c8c-fvjsw Total loading time: 0 Render date: 2026-11-16T23:06:25.296Z Has data issue: false hasContentIssue false

Evolution of corrosion parameters in a buried pilot nuclear waste container in el Cabril

Published online by Cambridge University Press:  03 July 2014

Carmen Andrade
Affiliation:
Institute of Construction Science “Eduardo Torroja” (IETcc), CSIC, Serrano Galvache 4, 28033, Madrid, Spain.
Samuel Briz
Affiliation:
Institute of Construction Science “Eduardo Torroja” (IETcc), CSIC, Serrano Galvache 4, 28033, Madrid, Spain.
Javier Sanchez
Affiliation:
Institute of Construction Science “Eduardo Torroja” (IETcc), CSIC, Serrano Galvache 4, 28033, Madrid, Spain.
Pablo Zuloaga
Affiliation:
ENRESA (Spanish Agency for Management of Radioactive Wastes) Emilio Vargas, 7, 28043, Madrid, Spain.
Mariano Navarro
Affiliation:
ENRESA (Spanish Agency for Management of Radioactive Wastes) Emilio Vargas, 7, 28043, Madrid, Spain.
Manuel Ordoñez
Affiliation:
ENRESA (Spanish Agency for Management of Radioactive Wastes) Emilio Vargas, 7, 28043, Madrid, Spain.
Get access

Abstract

Modern concrete has a record of good performance of around 120 years although there are structures in perfect conservation made with roman concrete (mixture of lime and natural pozzolans). El Cabril repository has a design life of 300-500 years and therefore, it should keep its integrity much longer than the back experience we have on reinforced concrete structures, which makes necessary a closer monitoring with time on the aging of concrete in real conditions. With this purpose, Enresa has designed in collaboration with IETcc and Geocisa the installation of permanent sensors in a pilot nuclear waste container in buried conditions. The sensors were installed in 1995 for monitoring corrosion parameters and have been working until present. The non-destructive tests (NDT) applied are based in electrochemical measurements (corrosion rate, corrosion potential, electrical resistivity, concrete strains, oxygen availability). Relations between the climatic influence, the buried depth and the corrosion parameters are also presented. The results indicate that temperature is a very relevant variable influencing the measurements. All the other parameters evolve according to seasonal changes. Values of activation energies of the resistivity changes are given although it seems more adequate to model the evolution with time by simply plotting the values registered at 20 ± 2 °C.

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable