Hostname: page-component-7b7567c8c-tnkh4 Total loading time: 0 Render date: 2026-11-16T23:51:38.177Z Has data issue: false hasContentIssue false

Failure Investigation of Polymer Mechanical Micromponents

Published online by Cambridge University Press:  26 February 2011

Yi Zhao
Affiliation:
pillypolly@gmail.com, The Ohio State University, Department of Biomedical Engineering, 294 Bevis Hall, 1080 Carmack Road, Columbus, OH, 43210, United States
Xin Zhang
Affiliation:
xinz@bu.edu, Boston University, Department of Manufacturing Engineering, 15 Saint Mary's Street, Bookline, MA, 02446, United States
Get access

Abstract

This paper reports typical failure modes of polymer microstructures. Polydimethylsiloxane (PDMS) microstructures were fabricated using replication-based methods. The mechanical collapses of these structures were observed using scanning electron microscopy. In this work, we classified the mechanical collapses based on their individual geometries and discussed the mechanism of each failure mode. We also worked on solutions to recover these failed PDMS structures. This work helps to better understand the collapsing mechanism and to facilitate the development of control strategies to enhance the mechanical reliability of polymer microdevices.

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable