Hostname: page-component-7b7567c8c-tnkh4 Total loading time: 0 Render date: 2026-11-16T22:57:47.305Z Has data issue: false hasContentIssue false

In situ determination of effective tip radius in dynamic atomic force microscopy

Published online by Cambridge University Press:  20 February 2014

C. Maragliano
Affiliation:
LENS Laboratory @ Institute Center for Future Energy Systems (iFES), Masdar Institute of Science and Technology, P.O.Box 54224, Abu Dhabi, UAE
A. Glia
Affiliation:
LENS Laboratory @ Institute Center for Future Energy Systems (iFES), Masdar Institute of Science and Technology, P.O.Box 54224, Abu Dhabi, UAE
M. Stefancich
Affiliation:
LENS Laboratory @ Institute Center for Future Energy Systems (iFES), Masdar Institute of Science and Technology, P.O.Box 54224, Abu Dhabi, UAE
M. Chiesa
Affiliation:
LENS Laboratory @ Institute Center for Future Energy Systems (iFES), Masdar Institute of Science and Technology, P.O.Box 54224, Abu Dhabi, UAE
Get access

Abstract

Atomic force microscopy (AFM) suffers from an important limitation: it does not provide quantitative information about the scanned sample. This is because too many unknowns come into play in AFM measurements. The shape of the tip is probably the most important. A technique able to characterize in situ the shape of the tip apex would represent an important step ahead to turn the AFM into a quantitative tool.

Standard methods can be destructive to the tip and are time consuming. Two main methods are currently used to characterize the tip radius in situ without affecting its shape. The first consists of characterizing the tip radius by monitoring the dynamics of the cantilever. The value of free amplitude, for which transitions from the attractive to repulsive force regimes are observed, strongly depends on the curvature of the tip. The second method to characterize the tip radius consists instead on fitting the capacitance curve of the tip-sample system with an analytical function.

In this work we compare the two methods to characterize in situ the tip radius and results are verified with SEM images. The value of the free amplitude is correlated with the value of R while the capacitance curve is derived with a method we proposed. Tips with different tip radii are used. The investigation is conducted with the aim of determining the most reliable technique for characterizing the tip radius for both sharp and blunt tips.

Information

Type
Articles
Copyright
Copyright © Materials Research Society 2014 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable