Hostname: page-component-7b7567c8c-z4zkx Total loading time: 0 Render date: 2026-11-18T09:31:47.597Z Has data issue: false hasContentIssue false

In Situ Wafer Emissivity Variation Measurement in a Rapid Thermal Processor

Published online by Cambridge University Press:  28 February 2011

J-M. Dilhac
Affiliation:
LAAS-CNRS, 7 avenue du colonel Roche, 31077 Toulouse CEDEX, FRANCE
C. Ganibal
Affiliation:
LAAS-CNRS, 7 avenue du colonel Roche, 31077 Toulouse CEDEX, FRANCE
N. Nolhier
Affiliation:
LAAS-CNRS, 7 avenue du colonel Roche, 31077 Toulouse CEDEX, FRANCE
Get access

Abstract

Wafer backside reflectivity measurements at room temperature have been performed in a rapid thermal processor equipped with two rows of heating lamps by measuring, with the process optical pyrometer, the light emitted by the lower row of the heating lamps and reflected by the wafer. The differences in reflectivity have been correlated with the process temperature variations induced by emissivity changes. Optical pyrometer recalibration procedures have then been established. It has been demonstrated that the reflectivity measurement, performed automatically for each wafer prior to the thermal cycle, may drastically improve the accuracy of temperature control.