Hostname: page-component-7b7567c8c-tnkh4 Total loading time: 0 Render date: 2026-11-16T16:27:16.812Z Has data issue: false hasContentIssue false

Metal Removal by Wafer Spin Cleaning Process with Advanced Chemical Distribution System

Published online by Cambridge University Press:  21 February 2011

Fumitomo Kunimoto
Affiliation:
Department of Electronics, Faculty of Engineering, Tohoku University Aza Aoba, Aramaki, Aoba–ku, Sendai, Japan, 980.
Tadahiro Ohmi
Affiliation:
Department of Electronics, Faculty of Engineering, Tohoku University Aza Aoba, Aramaki, Aoba–ku, Sendai, Japan, 980.
Frederick W. Kern Jr
Affiliation:
IBM Corporation, General Technology Division in ESSEX Junction, Vermont, USA
Get access

Abstract

In this report we studied the single wafer spin cleaning system. We found that spin cleaning efficiency increases as the flux of chemical is increased, as the cleaning time was extended. From the metal removal test, we found that we can greatly reduce both cleaning time and chemical consumption at the same time as compare to batch process. Furthermore, we found that spin cleaning efficiency is dependant on a combination of the two parameters, chemical flux and cleaning time. We have optimized the proper nozzle position for complete coverage of the wafer surface by analyzing the fluid dynamics of the liquid on the wafer surface during spin treatment.

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable