Hostname: page-component-7b7567c8c-7pwfn Total loading time: 0 Render date: 2026-11-16T20:07:54.843Z Has data issue: false hasContentIssue false

Neutron Transmutation Doping and Radiation Hardness for Solution-Grown Bulk and Nano-Structured ZnO

Published online by Cambridge University Press:  01 February 2011

Elena S. Flitsiyan
Affiliation:
flitsiyan@physics.ucf.edu, University of Central Florida, Physics, Orlando, Florida, United States
Casey M. Swartz
Affiliation:
minna233@comcast.net, University of Central Florida, Physics, Orlando, Florida, United States
Robert E. Peale
Affiliation:
rep@physics.ucf.edu, University of Central Florida, Physics, Orlando, Florida, United States
Oleg Lupan
Affiliation:
lupan@physics.ucf.edu, Technical University of Moldova, Microelectronic and Semiconductor Devices, Chisinay, Moldova
Leonid Chernyak
Affiliation:
chernyak@physics.ucf.edu, University of Central Florida, Physics, Orlando, Florida, United States
Lee Chow
Affiliation:
chow@pegasus.cc.ucf.edu, University of Central Florida, Physics, Orlando, Florida, United States
William G. Vernetson
Affiliation:
vernet@ufl.edu, University of Florida, Nuclear and Radiological Engineering, Gainesville, Florida, United States
Zinovi Dashevsky
Affiliation:
zdashev@bgu.ac.il, Ben-Gurion University of Negev, Materials Engineering, Beer-Sheva, Israel
Get access

Abstract

It is shown that solution-grown ZnO nanostructures exhibit enhanced radiation hardness against neutron irradiation as compared to bulk material. The decrease of the cathodoluminescence intensity after irradiation at a neutron dose of 6 × 1016 cm−2 in ZnO nanostructure is nearly identical to that induced by a dose of 1.5 × 1014 cm−2 in bulk material. The damage introduced by irradiation is shown to change the nature of electronic transitions responsible for luminescence. The change of excitonic luminescence to the luminescence related to the tailing of the density of states caused by potential fluctuations occurs at an irradiation dose around 6×1016 cm−2 and 5×1014 cm−2 in nanostructured and bulk materials, respectively.

Hall measurements before and after annealing determined the effect of dose on resistance, mobility, and carrier concentration. Annealing decreased the sheet resistance, increased the mobility, and increased carrier concentration for all doses. While the concentration of carriers in the control sample increased 200-fold after annealing, the increase was ∼1000-fold for the irradiated samples. Annealed irradiated samples showed a maximum carrier concentration increase of about 60x over the unirradiated sample. Interestingly, neutron irradiation increased the mobility even in the un-annealed samples.

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable