Hostname: page-component-7b7567c8c-z4zkx Total loading time: 0 Render date: 2026-11-17T04:39:10.750Z Has data issue: false hasContentIssue false

XPS Studies of the Si/SiO2 Interface With Synchrotron Radiation

Published online by Cambridge University Press:  10 February 2011

F. Rochet
Affiliation:
Laboratoire de Chimie-Physique, Matière et Rayonnement, Université Pierre et Marie Curie, 11 rue Pierre et Marie Curie, F-75231 Paris cedex 05, France, roch@ccr.jussieu.frLURE, Centre universitaire Paris Sud, bâtiment 209D, F-91898 Orsay cedex, France
F. Jolly
Affiliation:
Laboratoire de Chimie-Physique, Matière et Rayonnement, Université Pierre et Marie Curie, 11 rue Pierre et Marie Curie, F-75231 Paris cedex 05, France, roch@ccr.jussieu.fr
G. Dufour
Affiliation:
Laboratoire de Chimie-Physique, Matière et Rayonnement, Université Pierre et Marie Curie, 11 rue Pierre et Marie Curie, F-75231 Paris cedex 05, France, roch@ccr.jussieu.fr
C. Grupp
Affiliation:
LURE, Centre universitaire Paris Sud, bâtiment 209D, F-91898 Orsay cedex, France
A. Taleb-Ibrahimi
Affiliation:
LURE, Centre universitaire Paris Sud, bâtiment 209D, F-91898 Orsay cedex, France
Get access

Abstract

Si 2p core-level spectroscopy is a unique tool to determine the chemical composition and spatial extension of the suboxide layer present at the Si/SiO2 interface. In the case of ultra-thin oxide films (thickness <10 Å), the high surface sensitivity provided by the tunability of synchrotron radiation allows the observation of four energetically well-separated oxidation states, generally attributed to a silicon atom with an increasing number of oxygen first neighbors, and hence often denoted Sin+(with n=1,…,4). After a brief review of two decades of XPS studies on the Si/SiO2 interface, we give an account of the recent debate concerning the possible contribution of the second oxygen neighbor shell to the chemical shift, which, if effective, would modify the picture of the interface. Then, we examine the benefit derived from the use of very high energy resolution (70 meV at hv=130 eV), and we try to determine, for this system, what are the limits of this spectroscopy. To illustrate the latter point, among various case studies (thermal oxides, room temperature adsorption etc.), we treat in more detail the case of the H-terminated Si(1 11) surface oxidized by atomic oxygen, and discuss our data in the light of previous XPS and vibrational spectroscopy studies.

Information

Type
Research Article
Copyright
Copyright © Materials Research Society 2000

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable