Hostname: page-component-7b7567c8c-fvjsw Total loading time: 0 Render date: 2026-11-17T09:10:02.260Z Has data issue: false hasContentIssue false

Numerical Schemes for Linear and Non-Linear Enhancement of DW-MRI

Published online by Cambridge University Press:  28 May 2015

Eric Creusen*
Affiliation:
Department of Mathematics and Computer Science, CASA Applied Analysis, Eindhoven University of Technology, P.O. Box 513, 5600 MB, Eindhoven, The Netherlands
Remco Duits*
Affiliation:
Department of Mathematics and Computer Science, CASA Applied Analysis, Eindhoven University of Technology, P.O. Box 513, 5600 MB, Eindhoven, The NetherlandsDepartment of Biomedical Engineering, BMIA Biomedical Image Analysis, Eindhoven University of Technology, P.O. Box 513, 5600 MB, Eindhoven, The Netherlands
Anna Vilanova
Affiliation:
Department of Biomedical Engineering, BMIA Biomedical Image Analysis, Eindhoven University of Technology, P.O. Box 513, 5600 MB, Eindhoven, The Netherlands
Luc Florack
Affiliation:
Department of Mathematics and Computer Science, CASA Applied Analysis, Eindhoven University of Technology, P.O. Box 513, 5600 MB, Eindhoven, The NetherlandsDepartment of Biomedical Engineering, BMIA Biomedical Image Analysis, Eindhoven University of Technology, P.O. Box 513, 5600 MB, Eindhoven, The Netherlands
*
Corresponding author.Email address:e.j.creusen@tue.nl
Corresponding author.Email address:r.duits@tue.nl
Get access

Abstract

We consider the linear and non-linear enhancement of diffusion weighted magnetic resonance images (DW-MRI) to use contextual information in denoising and inferring fiber crossings. We describe the space of DW-MRI images in a moving frame of reference, attached to fiber fragments which allows for convection-diffusion along the fibers. Because of this approach, our method is naturally able to handle crossings in data. We will perform experiments showing the ability of the enhancement to infer information about crossing structures, even in diffusion tensor images (DTI) which are incapable of representing crossings themselves. We will present a novel non-linear enhancement technique which performs better than linear methods in areas around ventricles, thereby eliminating the need for additional preprocessing steps to segment out the ventricles. We pay special attention to the details of implementation of the various numeric schemes.

Information

Type
Research Article
Copyright
Copyright © Global Science Press Limited 2013

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable