Hostname: page-component-7b7567c8c-2n9c9 Total loading time: 0 Render date: 2026-11-14T06:42:16.763Z Has data issue: false hasContentIssue false

Influence of the sample morphology on total reflection X-ray fluorescence analysis

Published online by Cambridge University Press:  29 February 2012

C. Horntrich
Affiliation:
Vienna University of Technology, Atominstitut, Stadionallee 2, 1020 Vienna, Austria
F. Meirer
Affiliation:
Vienna University of Technology, Atominstitut, Stadionallee 2, 1020 Vienna, Austria
C. Streli
Affiliation:
Vienna University of Technology, Atominstitut, Stadionallee 2, 1020 Vienna, Austria
P. Kregsamer
Affiliation:
Vienna University of Technology, Atominstitut, Stadionallee 2, 1020 Vienna, Austria
G. Pepponi
Affiliation:
FBK-irst, via Sommarive 18, 38050 Povo (Trento), Italy
N. Zoeger
Affiliation:
Vienna University of Technology, Atominstitut, Stadionallee 2, 1020 Vienna, Austria
P. Wobrauschek
Affiliation:
Vienna University of Technology, Atominstitut, Stadionallee 2, 1020 Vienna, Austria
Get access

Abstract

Total reflection X-ray fluorescence analysis (TXRF) is a method for qualitative and quantitative analysis of trace elements. In general TXRF is known to allow for linear calibration typically using an internal standard for quantification. For small sample amounts (low ng region) the thin film approximation is valid neglecting absorption effects of the exciting and the detected radiation. However, for higher total amounts of samples deviations from the linear relation between fluorescence intensity and sample amount have been observed. The topic of the presented work is an investigation of the parameters influencing the absorption phenomenon. Samples with different total amounts of arsenic have been prepared to determine the upper limit of sample mass where the linear relation between fluorescence intensity and sample amount is no longer guaranteed. It was found that the relation between fluorescence intensity and sample amount is linear up to ∼100 ng arsenic. A simulation model was developed to calculate the influence of the absorption effects. Even though the results of the simulations are not satisfying yet it could be shown that one of the key parameters for the absorption effect is the density of the investigated element in the dried residues.

Information

Type
X-Ray Fluorescence
Copyright
Copyright © Cambridge University Press 2009

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable