Hostname: page-component-74656f9884-8r8nv Total loading time: 0 Render date: 2026-11-10T04:32:16.832Z Has data issue: false hasContentIssue false

A practical approach to Rietveld analysis. Comparison of some programs running on personal computers

Published online by Cambridge University Press:  10 January 2013

Lj. Karanović
Affiliation:
Crystallographic Laboratory, Faculty of Mining and Geology, University of Belgrade, Djušina 7, 11000 Belgrade, Yugoslavia
I. Petrović-Prelević
Affiliation:
Crystallographic Laboratory, Faculty of Mining and Geology, University of Belgrade, Djušina 7, 11000 Belgrade, Yugoslavia
D. Poleti
Affiliation:
Department of General and Inorganic Chemistry, Faculty of Technology and Metallurgy, University of Belgrade, P.O. Box 494, 11001 Belgrade, Yugoslavia
Get access

Abstract

Three computer programs for Rietveld analysis DBWS-9411, HILL-93.06, and FULLPROF-3.1 have been tested and compared using data for two samples of different complexity, spinel, and anglesite. The investigation shows that results are “program dependent.” The obtained R indices for spinel are in the ranges 10.60%–13.26%(Rwp) and 3.15%–5.25%(RB). Similarly, the ranges for anglesite are 9.76%–14.06%(Rwp) and 2.15%–5.06%(RB). Some atom and displacement parameters are significantly different, too. In attempt to define the standard procedure for Rietveld analysis, three parameters, n, BKPOS, and RLIM were examined. It was found that the most appropriate values for them are: n=8–10, BKPOS=90°, and RLIM=40° 2θ. Using Fourier filtering for background modeling, significantly lower R indices were obtained in comparison to polynomial and interpolated background. At the same time the great numbers of atom and cell parameters agree within ±3σmax and e.s.d.'s were identical or lower than those achieved for polynomial and interpolated background. It was found that the function given by Bérar and Baldinozzi (1993) (J. Appl. Crystallogr. 26, 128–129) much better described asymmetric peak profiles at low 2θ angles. This function and Fourier filtering were implemented only in FULLPROF, which has more possibilities and some advantages over the other two programs. In addition, the peak shift parameters (sample displacement and transparency) were tested. It was shown that under present circumstances these parameters do not have much effect on atom parameters and R indices. However, differences in unit cell parameters were considerable greater, most probably because of the large correlation between zero-point, lattice, and peak shift parameters.

Information

Type
Research Article
Copyright
Copyright © Cambridge University Press 1999

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable