Hostname: page-component-7b7567c8c-wxvwp Total loading time: 0 Render date: 2026-11-17T22:56:37.829Z Has data issue: false hasContentIssue false

Progress in AMS Target Production of Sub-Milligram Samples at the NERC Radiocarbon Laboratory

Published online by Cambridge University Press:  18 July 2016

Tanya Ertunç*
Affiliation:
Natural Environment Research Council (NERC) Radiocarbon Laboratory, Scottish Enterprise Technology Park, Rankine Avenue, East Kilbride G75 0QF, United Kingdom
Sheng Xu
Affiliation:
Scottish Universities Environmental Research Centre (SUERC), Scottish Enterprise Technology Park, East Kilbride G75 0QF, United Kingdom
Charlotte L Bryant
Affiliation:
Natural Environment Research Council (NERC) Radiocarbon Laboratory, Scottish Enterprise Technology Park, Rankine Avenue, East Kilbride G75 0QF, United Kingdom
Colin Maden
Affiliation:
Scottish Universities Environmental Research Centre (SUERC), Scottish Enterprise Technology Park, East Kilbride G75 0QF, United Kingdom
Callum Murray
Affiliation:
Natural Environment Research Council (NERC) Radiocarbon Laboratory, Scottish Enterprise Technology Park, Rankine Avenue, East Kilbride G75 0QF, United Kingdom
Margaret Currie
Affiliation:
Natural Environment Research Council (NERC) Radiocarbon Laboratory, Scottish Enterprise Technology Park, Rankine Avenue, East Kilbride G75 0QF, United Kingdom
Stewart P H T Freeman
Affiliation:
Scottish Universities Environmental Research Centre (SUERC), Scottish Enterprise Technology Park, East Kilbride G75 0QF, United Kingdom
*
Corresponding author. Email: T.Ertunc@nercrcl.gla.ac.uk.
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the 'Save PDF' action button.

Recent progress in graphite target production for sub-milligram environmental samples in our facility is presented. We describe an optimized hydrolysis procedure now routinely used for the preparation of CO2 from inorganic samples, a new high-vacuum line dedicated to small sample processing (combining sample distillation and graphitization units), as well as a modified graphitization procedure. Although measurements of graphite targets as small as 35 μg C have been achieved, system background and measurement uncertainties increase significantly below 150 μg C. As target lifetime can become critically short for targets <150 μg C, the facility currently only processes inorganic samples down to 150 μg C. All radiocarbon measurements are made at the Scottish Universities Environmental Research Centre (SUERC) accelerator mass spectrometry (AMS) facility. Sample processing and analysis are labor-intensive, taking approximately 3 times longer than samples ≥ 500 μg C. The technical details of the new system, graphitization yield, fractionation introduced during the process, and the system blank are discussed in detail.

Information

Type
Articles
Copyright
Copyright © 2005 by the Arizona Board of Regents on behalf of the University of Arizona