No CrossRef data available.
Published online by Cambridge University Press: 18 July 2016
Although acid leaching of shell carbonates prior to 14C assay is usually desirable, under some circumstances it can worsen contamination by preferentially dissolving unaltered shell and thus increasing the proportion of secondary carbonate. The risk can be eliminated by monitoring the progress of leaching with the help of microscopy and x-ray diffraction.