Hostname: page-component-7b7567c8c-2n9c9 Total loading time: 0 Render date: 2026-11-15T09:51:50.155Z Has data issue: false hasContentIssue false

Statistical analysis of measured operators’ finger doses ininterventional radiology

Published online by Cambridge University Press:  23 January 2014

J.A. Feghali
Affiliation:
IRSN, Pôle Radioprotection Homme, BP 17, 92262 Fontenay-aux-Roses, France
F. Tagnard-Mérat
Affiliation:
IRSN, Pôle Radioprotection Homme, BP 17, 92262 Fontenay-aux-Roses, FranceService de Médecine de Prévention du Ministère de la Défense, Centre de Médecine Prévention des Armées de Paris/EHMP site de Paris 5, 74 boulevard de Port-Royal, 75230 Paris Cedex 05, France
L. Donadille
Affiliation:
IRSN, Pôle Radioprotection Homme, BP 17, 92262 Fontenay-aux-Roses, France
J.L. Rehel
Affiliation:
IRSN, Pôle Radioprotection Homme, BP 17, 92262 Fontenay-aux-Roses, France
B. Aubert
Affiliation:
IRSN, Pôle Radioprotection Homme, BP 17, 92262 Fontenay-aux-Roses, France
R. Allodji
Affiliation:
IRSN, Pôle Radioprotection Homme, BP 17, 92262 Fontenay-aux-Roses, France
C. Gauron
Affiliation:
INRS, Département EAM, 75680 Paris Cedex 14, France
J. Farah*
Affiliation:
IRSN, Pôle Radioprotection Homme, BP 17, 92262 Fontenay-aux-Roses, France
I. Clairand
Affiliation:
IRSN, Pôle Radioprotection Homme, BP 17, 92262 Fontenay-aux-Roses, France

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the 'Save PDF' action button.

This work suggests a classification of interventional radiology and cardiology proceduresbased on statistical analysis of operators’ finger doses measured in routine clinicalconditions. In total, 346 finger doses were measured and the observed mean finger dose perclass of procedure ranged from 0.03 mSv to 1.56 mSv for Cerebral, and Bone and Jointprocedures, respectively. The statistical analysis showed that the finger dose in Cerebralprocedures is significantly lower than in Cardiac procedures, which was significantlylower than the rest. Furthermore, finger doses in therapeutic procedures and in close oneswere significantly greater than in diagnostic procedures and in distal ones. This workalso studied the statistical relation between the use of ceiling-suspended shields orleaded gloves and the extremity dose. From the set of collected and analyzed data, afinger dose classification was proposed for different criteria: procedure type(diagnostics/therapeutic), proximity (close/distal), procedure class and access route.

Information

Type
Article
Copyright
© EDP Sciences, 2014