Hostname: page-component-7b7567c8c-fvjsw Total loading time: 0 Render date: 2026-11-13T10:03:11.827Z Has data issue: false hasContentIssue false

Robot-assisted perception augmentation for online detection of insertion failure during cochlear implant surgery

Published online by Cambridge University Press:  09 June 2016

J. Pile
Affiliation:
Department of Mechanical Engineering, Vanderbilt University, Nashville, TN 37235 USA. E-mail: jason.pile@vanderbilt.edu
G. B. Wanna
Affiliation:
Department of Otolaryngology Head & Neck Surgery, Vanderbilt University, Nashville, TN 37235 USA. E-mail: george.wanna@vanderbilt.edu
N. Simaan*
Affiliation:
Department of Mechanical Engineering, Vanderbilt University, Nashville, TN 37235 USA. E-mail: jason.pile@vanderbilt.eduDepartment of Otolaryngology Head & Neck Surgery, Vanderbilt University, Nashville, TN 37235 USA. E-mail: george.wanna@vanderbilt.edu
*
*Corresponding author. E-mail: nabil.simaan@vanderbilt.edu
Rights & Permissions [Opens in a new window]

Summary

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the 'Save PDF' action button.

During the past decade, robotics for cochlear implant electrode array insertion has been limited to manipulation assistance. Going beyond manipulation assistance, this paper presents the new concept of perception augmentation to detect and warn against the onset of intracochlear electrode array tip folding. This online failure detection method uses a combination of intraoperative electrode insertion force data and a predictive model of insertion force profile progression as a function of insertion depth. The predictive model uses statistical characterization of insertion force profiles during normal robotic electrode array insertions as well as the history of intra-operative insertion forces. Online detection of onset of tip folding is achieved using the predictive model as an input into a support vector machine classifier. Results show that the detection of tip folding onset can be achieved with an accuracy of 88% despite the use of intra-operative insertion force data representing incomplete insertion. This result is significant because it allows the surgeon or robot to choose a corrective action for preventing intra-cochlear complications.

Information

Type
Articles
Copyright
Copyright © Cambridge University Press 2016 
Supplementary material: Image

Pile supplementary material

Figure S1

Download Pile supplementary material(Image)
Image 830.2 KB
Supplementary material: Image

Pile supplementary material

Figure S2

Download Pile supplementary material(Image)
Image 100.9 KB
Supplementary material: Image

Pile supplementary material

Figure S3

Download Pile supplementary material(Image)
Image 177.2 KB
Supplementary material: Image

Pile supplementary material

Figure S4

Download Pile supplementary material(Image)
Image 145 KB
Supplementary material: Image

Pile supplementary material

Figure S5

Download Pile supplementary material(Image)
Image 588.4 KB
Supplementary material: Image

Pile supplementary material

Figure S6

Download Pile supplementary material(Image)
Image 58.9 KB
Supplementary material: Image

Pile supplementary material

Figure S7

Download Pile supplementary material(Image)
Image 45.9 KB
Supplementary material: Image

Pile supplementary material

Figure S8

Download Pile supplementary material(Image)
Image 27.7 KB
Supplementary material: Image

Pile supplementary material

Figure S9

Download Pile supplementary material(Image)
Image 39.2 KB

Pile supplementary material

Media 1

Download Pile supplementary material(Video)
Video 7.9 MB
Supplementary material: PDF

Pile supplementary material

Pile supplementary material 1

Download Pile supplementary material(PDF)
PDF 2.3 MB
Supplementary material: File

Pile supplementary material

Pile supplementary material 2

Download Pile supplementary material(File)
File 97.9 KB