Hostname: page-component-7b7567c8c-wxvwp Total loading time: 0 Render date: 2026-11-18T19:53:14.451Z Has data issue: false hasContentIssue false

Effects of 2,4-D Formulation and Quinclorac on Spray Droplet Size and Deposition

Published online by Cambridge University Press:  20 January 2017

Audie S. Sciumbato
Affiliation:
Texas Agricultural Experiment Station, Department of Soil and Crop Sciences, Texas A&M University, College Station, TX 77843-2474
Scott A. Senseman*
Affiliation:
Texas Agricultural Experiment Station, Department of Soil and Crop Sciences, Texas A&M University, College Station, TX 77843-2474
Jim Ross
Affiliation:
Agricultural Experiment Station, Department of Entomology, Plant Pathology, and Weed Science, Las Cruces, NM 88003-8003
Tom C. Mueller
Affiliation:
Department of Plant Sciences, University of Tennessee Knoxville, TN 37996-4561
James M. Chandler
Affiliation:
Texas Agricultural Experiment Station, Department of Soil and Crop Sciences, Texas A&M University, College Station, TX 77843–2474
Joe T. Cothren
Affiliation:
Texas Agricultural Experiment Station, Department of Soil and Crop Sciences, Texas A&M University, College Station, TX 77843–2474
Ivan W. Kirk
Affiliation:
USDA-ARS, 2771 F&B Road, College Station, TX 77845
*
Corresponding author's E-mail: s-senseman@tamu.edu

Abstract

Studies were conducted on the campuses of Texas A&M University in College Station, TX, and New Mexico State in Las Cruces, NM, to determine the spray droplet size spectra produced by quinclorac and 2,4-D as the liquid, dry, and emulsion formulations during application with various nozzle sizes using a laser spectrometer. Quinclorac and 2,4-D formulations were also sprayed through three different nozzle sizes in a drift chamber and allowed to settle on glass slides placed downwind. The amounts of each herbicide deposited on the slides were quantified using high-performance liquid chromatography/photodiode array (HPLC/PDA) analysis to assess spray deposition of each formulation at different wind velocities. Data from the laser spectrometer suggested that formulations of 2,4-D affected droplet size, particularly when the 380 ml/min flat-fan nozzle was used. Quinclorac droplet sizes were similar to water regardless of nozzle size. Liquid and dry-formulated 2,4-D tended to be deposited downwind in greater quantities than the emulsion formulation when using the 380 and 760 ml/min spray nozzles with wind velocity of 15 km/h.

Information

Type
Research Article
Copyright
Copyright © Weed Science Society of America 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable