Hostname: page-component-6898cfcb55-cbk24 Total loading time: 0 Render date: 2026-11-11T16:33:21.579Z Has data issue: false hasContentIssue false

A Monte Carlo study of the dose enhancement effects of high-z foils in proton therapy

Published online by Cambridge University Press:  13 March 2023

Kristen Duke
Affiliation:
Department of Radiation Oncology, University of Oklahoma Health Sciences Center, Oklahoma City, OK, USA
Salahuddin Ahmad*
Affiliation:
Department of Radiation Oncology, University of Oklahoma Health Sciences Center, Oklahoma City, OK, USA
Andy Lau
Affiliation:
Department of Radiation Oncology, University of Oklahoma Health Sciences Center, Oklahoma City, OK, USA
*
Author for correspondence: Salahuddin Ahmad, Department of Radiation Oncology, University of Oklahoma Health Sciences Center, Stephenson Cancer Center, 800 NE 10th Street, SCC L 100, Oklahoma City, OK 73104, USA. E-mail: Salahuddin-ahmad@ouhsc.edu
Rights & Permissions [Opens in a new window]

Abstract

Background:

This investigation quantifies the dose enhancement effect and dose distribution modifications due to the presence of high-z nanospheres in a proton beam.

Methods:

Various proton pencil beams of therapeutic energies (60–226 MeV) and spatial distribution of 2·7 mm spot size diameter were simulated onto a water phantom utilising the TOPAS Monte Carlo toolkit version 3.6.1. The simulation modelled either water or nanospheres of high-z materials (gold, silver or platinum) at the location of the Bragg Peak (BP) to compare the differences of the resulting dose distributions.

Results:

The introduction of the nanospheres increases the maximum dose, narrows the BP and shifts the BP location upstream compared to the water phantom with no nanospheres.

Conclusions:

This work shows that the local dose can be enhanced with the use of high-z nanoparticles in proton therapy, thereby increasing patient safety and decreasing side effects with the same amount of delivered radiation.

Information

Type
Original Article
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2023. Published by Cambridge University Press
Figure 0

Table 1.Application of physics lists used for the custom modular physics list, data5–7 are used.

Figure 1

Figure 1.Phantom geometries. (Upper) Empty control water phantom with 226 MeV proton beam. (Lower) Water phantom with high-z metal foil placed in 80–80% Bragg Peak, with a 226 MeV proton beam.

Figure 2

Table 2.Foil width and placement for various energies.

Figure 3

Figure 2.Initial geometry, with 50 nm individual metal particles arranged into walls of ‘foils’ for a desired high-z density (not to scale).

Figure 4

Figure 3.Initial small scale phantom setup showing 50 nm foils with 50 nm water spacing in between.

Figure 5

Table 3.Bragg Peak (BP) shifts upstream, narrowing and dose enhancement factors of 60, 100, 160 and 226 MeV for silver, gold and platinum.

Figure 6

Figure 4.226 MeV Bragg Peak shifts of silver, gold and platinum for depth 30·45–30·72 cm.

Figure 7

Figure 5.Dose enhancement factor of silver, gold and platinum foils at 226 MeV.