Hostname: page-component-7b7567c8c-fvjsw Total loading time: 0 Render date: 2026-11-16T11:43:12.314Z Has data issue: false hasContentIssue false

Instability and transition control by steady local blowing/suction in a hypersonic boundary layer

Published online by Cambridge University Press:  14 August 2024

Guo-Hui Zhuang
Affiliation:
Department of Modern Mechanics, University of Science and Technology of China, Hefei 230027, PR China
Zhen-Hua Wan*
Affiliation:
Department of Modern Mechanics, University of Science and Technology of China, Hefei 230027, PR China
Nan-Sheng Liu
Affiliation:
Department of Modern Mechanics, University of Science and Technology of China, Hefei 230027, PR China
De-Jun Sun*
Affiliation:
Department of Modern Mechanics, University of Science and Technology of China, Hefei 230027, PR China
Xi-Yun Lu
Affiliation:
Department of Modern Mechanics, University of Science and Technology of China, Hefei 230027, PR China
*
†Email addresses for correspondence: wanzh@ustc.edu.cn, dsun@ustc.edu.cn
†Email addresses for correspondence: wanzh@ustc.edu.cn, dsun@ustc.edu.cn

Abstract

The efficacy of steady large-amplitude blowing/suction on instability and transition control for a hypersonic flat plate boundary layer with Mach number 5.86 is investigated systematically. The influence of the blowing/suction flux and amplitude on instability is examined through direct numerical simulation and resolvent analysis. When a relatively small flux is used, the two-dimensional instability critical frequency that distinguishes the promotion/suppression mode effect closely aligns with the synchronisation frequency. For the oblique wave, as the spanwise wavenumber increases, the suppression effects would become weaker and the mode suppression bandwidth diminishes/increases in general in the blowing/suction control. Increasing the blowing/suction flux can effectively broaden the frequency bandwidth of disturbance suppression. The influence of amplitude on disturbance suppression is weak in a scenario of constant flux. To gain a deeper insight into disturbance suppression mechanism, momentum potential theory (MPT) and kinetic energy budget analysis are further employed in analysing disturbance evolution with and without control. When the disturbance is suppressed, the blowing induces the transport of certain acoustic components along the compression wave out of the boundary layer, whereas the suction does not. The velocity fluctuations are derived from the momentum fluctuations of the MPT. Compared with the momentum fluctuations, the evolutions indicated by each component's velocity fluctuations greatly facilitate the investigations of the acoustic nature of the second mode. The rapid variation of disturbance amplitude near the blowing is caused by the oscillations of the acoustic component and phase speed differences between vortical and thermal components. Kinetic energy budget analysis is performed to address the non-parallel effect of the boundary layer introduced by blowing/suction, which tends to suppress disturbances near the blowing. Moreover, viscous effects leading to energy dissipation are identified to be stronger in regions where the boundary layer is rapidly thickening. Finally, it is demonstrated that a flat plate boundary layer transition triggered by a random disturbance can be delayed by a blowing/suction combination control. The resolvent analysis further demonstrates that disturbances with frequencies that dominate the early transition stage are dampened in the controlled base flow.

Information

Type
JFM Papers
Copyright
© The Author(s), 2024. Published by Cambridge University Press
Figure 0

Figure 1.Sketch of the DNS domain over a flat plate, along with the boundary conditions.

Figure 1

Table 1.Simulation parameters for various cases. $A_0$ is $0.01U_\infty ^*$. The B or S in the notation indicates the flux of blowing or suction control and A indicates the amplitude.

Figure 2

Figure 2.The streamwise evolution of pressure near the wall in cases (a) B2A2, B3A3, B6A6, S3A3, and (b) B2AH, B3AH, B6AH, S3AH. The grey rectangular background represents the streamwise range of the blowing/suction in (a). The purple, yellow, red and green rectangular backgrounds represent the streamwise ranges of slots for cases B2AH, B3AH, B6AH and S3AH, respectively.

Figure 3

Figure 3.The streamwise velocity contours in (a) case B3A3 and (b) case S3A3. The black line is the sonic line ($c=U+a$) whose phase speed is $c=5.5$ without control (solid line) and with control (dashed line).

Figure 4

Figure 4.The wavenumber evolution obtained by the wavelet analysis operated on the pressure near the wall: (a) $F=4.8\times 10^{-5}$ in case B3A3, (b) $F=7.2\times 10^{-5}$ in case B3A3, (c) $F=4.8\times 10^{-5}$ in case S3A3, (d) $F=7.2\times 10^{-5}$ in case S3A3.

Figure 5

Figure 5.The streamwise evolution of mode amplitude for defining the amplification coefficient (a) in a relatively long distance, (b) near the blowing/suction.

Figure 6

Figure 6.The dependency of amplification coefficient $C_A$ on the frequencies for different fluxes. Blowing control with the flux of (a) $\mathcal {F}_c=2$, (b) $\mathcal {F}_c=3.2$ and (c) $\mathcal {F}_c=6$. Suction control with the flux of (d) $\mathcal {F}_c=-3.2$. The blue vertical dashed line is the synchronisation frequency.

Figure 7

Figure 7.The grey background shows the optimal gain distribution with respect to $F$ and $\beta$ for the uncontrolled case B0A0. The solid/dashed lines denote contours of $\mu _c/\mu _{uc}=1$, in which $\mu _c$ is the optimal gain in controlled cases, and $\mu _{uc}$ is the optimal gain in uncontrolled case B0A0. Those curves that follow in the high optimal gain region are critical curves.

Figure 8

Figure 8.The grey background shows the optimal gain with respect to $F$ and $\beta$ for controlled cases: (a) B2A2, (b) B3A3, (c) B6A6, (d) S2A2, (e) S3A3, (f) S6A6. The solid lines denote contours of different $\mu _c/\mu _{uc}$, in which $\mu _c$ is the optimal gain in controlled cases, and $\mu _{uc}$ is the optimal gain in case B0A0.

Figure 9

Figure 9.Comparison of optimal gains with the same control flux but different control amplitude. The grey background shows optimal gain with respect to $F$ and $\beta$ for controlled cases: (a) B2A2, (b) B3A3, (c) B6A6, (d) S3A3. Solid lines denote those contours of $\log _{10}(\mu )$ in cases B2A2, B3A3, B6A6 and S3A3, respectively. Dashed lines denote those contours of $\log _{10}(\mu )$ in cases B2AH, B3AH, B6AH and S3AH, respectively.

Figure 10

Figure 10.The (a,c) forcing and (b,d) response modes in cases (a,b) B3A3 and (c,d) S3A3, with $F=4.5\times 10^{-5}$. The green dashed line is the GIP near the boundary edge.

Figure 11

Figure 11.Flux lines of the (a,b) vortical, (c,d) acoustic and (e,f) thermal components in (a,c,e) case B3A3 with $F=5.7\times 10^{-5}$, and (b,d,f) case S3A3 with $F=5.7\times 10^{-5}$. The control slots are all located in the range $x\in [89.9,90.9]$. The arrow directions denote the blowing or suction. The contours are coloured by each component's magnitude.

Figure 12

Figure 12.The acoustic component flux lines for (a) blowing control in case B3A3 with $F=5.7\times 10^{-5}$, and (b) suction control in case S3A3 with $F=5.7\times 10^{-5}$. The contours are coloured by the average pressure.

Figure 13

Figure 13.The streamwise evolution of (a) momentum components and (b) velocity components in MPT. The disturbance frequency is $F=5.4\times 10^{-5}$, and the vertical dashed line marks the synchronisation point.

Figure 14

Figure 14.The streamwise evolution of (a) acoustic component, (b) vortical component, (c) thermal component, and (d) the sum of vortical and thermal components, in cases B3A3 and S3A3, with frequency $F=5.7\times 10^{-5}$.

Figure 15

Figure 15.The streamwise evolution of $\mathcal {L}$, $\mathcal {P}$, $\varXi$, $\varPi$ and $\mathcal {V}$ in the linear energy transfer term of (a) blowing control and (b) suction control. The streamwise evolution of $\varXi$, $\varXi _1$ and $\varXi _2$ in the non-parallel term for (c) blowing control and (d) suction control.

Figure 16

Figure 16.(a) The $C_f$ evolution of transition flow without and with the steady blowing/suction control. The instantaneous wall pressure contours (b) without control and (c) with control.

Figure 17

Figure 17.The grey background shows optimal gain with respect to $F$ and $\beta$ for base flow (a) without control and (b) with control. The solid lines denote those contours of different $\mu _c/\mu _{uc}$, in which $\mu _c$ is the optimal gain with control, and $\mu _{uc}$ is the optimal gain without control. The frequency spectrum evolution of 2-D disturbances (c) without control and (d) with control. The dashed line marks the peak frequency of the resolvent analysis of the uncontrolled base flow.