Hostname: page-component-7b7567c8c-2rsb6 Total loading time: 0 Render date: 2026-11-12T07:02:08.661Z Has data issue: false hasContentIssue false

Proton imaging of stochastic magnetic fields

Published online by Cambridge University Press:  19 December 2017

A. F. A. Bott*
Affiliation:
Department of Physics, University of Oxford, Parks Road, Oxford OX1 3PU, UK
C. Graziani
Affiliation:
FLASH Center for Computational Science, University of Chicago, 5640 S. Ellis Ave, Chicago, IL 60637, USA
P. Tzeferacos
Affiliation:
Department of Physics, University of Oxford, Parks Road, Oxford OX1 3PU, UKFLASH Center for Computational Science, University of Chicago, 5640 S. Ellis Ave, Chicago, IL 60637, USA
T. G. White
Affiliation:
Department of Physics, University of Oxford, Parks Road, Oxford OX1 3PU, UKDepartment of Physics, University of Nevada, Reno, NV 89557, USA
D. Q. Lamb
Affiliation:
FLASH Center for Computational Science, University of Chicago, 5640 S. Ellis Ave, Chicago, IL 60637, USA
G. Gregori
Affiliation:
Department of Physics, University of Oxford, Parks Road, Oxford OX1 3PU, UK
A. A. Schekochihin
Affiliation:
Merton College, Merton Street, Oxford OX1 4JD, UKRudolf Peierls Centre for Theoretical Physics, University of Oxford, 1 Keble Road, Oxford OX1 3NP, UK
*
†Email address for correspondence: archie.bott@physics.ox.ac.uk
Rights & Permissions [Opens in a new window]

Abstract

Recent laser-plasma experiments (Fox et al., Phys. Rev. Lett., vol. 111, 2013, 225002; Huntington et al., Nat. Phys., vol. 11(2), 2015, 173–176; Tzeferacos et al., Phys. Plasmas, vol. 24(4), 2017a, 041404; Tzeferacos et al., 2017b, arXiv:1702.03016 [physics.plasm-ph]) report the existence of dynamically significant magnetic fields, whose statistical characterisation is essential for a complete understanding of the physical processes these experiments are attempting to investigate. In this paper, we show how a proton-imaging diagnostic can be used to determine a range of relevant magnetic-field statistics, including the magnetic-energy spectrum. To achieve this goal, we explore the properties of an analytic relation between a stochastic magnetic field and the image-flux distribution created upon imaging that field. This ‘Kugland image-flux relation’ was previously derived (Kugland et al., Rev. Sci. Instrum. vol. 83(10), 2012, 101301) under simplifying assumptions typically valid in actual proton-imaging set-ups. We conclude that, as with regular electromagnetic fields, features of the beam’s final image-flux distribution often display a universal character determined by a single, field-scale dependent parameter – the contrast parameter $\unicode[STIX]{x1D707}\equiv d_{s}/{\mathcal{M}}l_{B}$ – which quantifies the relative size of the correlation length $l_{B}$ of the stochastic field, proton displacements $d_{s}$ due to magnetic deflections and the image magnification ${\mathcal{M}}$ . For stochastic magnetic fields, we establish the existence of four contrast regimes, under which proton-flux images relate to their parent fields in a qualitatively distinct manner. These are linear, nonlinear injective, caustic and diffusive. The diffusive regime is newly identified and characterised. The nonlinear injective regime is distinguished from the caustic regime in manifesting nonlinear behaviour, but as in the linear regime, the path-integrated magnetic field experienced by the beam can be extracted uniquely. Thus, in the linear and nonlinear injective regimes we show that the magnetic-energy spectrum can be obtained under a further statistical assumption of isotropy. This is not the case in the caustic or diffusive regimes. We discuss complications to the contrast-regime characterisation arising for inhomogeneous, multi-scale stochastic fields, which can encompass many contrast regimes, as well as limitations currently placed by experimental capabilities on one’s ability to extract magnetic-field statistics. The results presented in this paper are of consequence in providing a comprehensive description of proton images of stochastic magnetic fields, with applications for improved analysis of proton-flux images.

Information

Type
Research Article
Copyright
© Cambridge University Press 2017 
Figure 0

Figure 1.Set-up of proton-imaging diagnostic, with identified theoretical parameters. A particular magnetic-field configuration is imaged by propagating an approximately planar proton beam through the structure. Spatially varying magnetic forces cause non-uniform deflection of protons, resulting in a particular proton-flux image. Here $r_{i}$ is the distance from the proton source to the magnetic field configuration, $a$ the proton-source size, $l_{\bot }$ the perpendicular length scale of the configuration, $l_{z}$ the parallel scale, $r_{s}$ the distance from the configuration to the detector, $\boldsymbol{x}_{\bot 0}$ a perpendicular coordinate system for the imaging beam prior to interaction with the magnetic field, $\boldsymbol{x}_{\bot }$ a perpendicular coordinate system after the interaction and $\boldsymbol{x}_{\bot }^{(s)}$ the image coordinate system.

Figure 1

Figure 2.Sample of Gaussian compact stochastic magnetic field configuration for use in illustration of contrast regimes (§ 3). The field sample is taken to have length scales $l_{i}=l_{z}=l_{\bot }=0.1~\text{cm}$, and is specified on a $201^{3}$ array (grid spacing $\unicode[STIX]{x1D6FF}x=l_{i}/201$). The sample is generated using the methods described in § P.2. The magnetic-energy spectrum is set to be a Golitsyn power law of the form (3.1), with index $p=-11/3$, spectral cutoffs $k_{l}=6\unicode[STIX]{x03C0}/l_{i}$, $k_{u}=120\unicode[STIX]{x03C0}/l_{i}$, $B_{\text{rms}}=1~\text{kG}$ and $l_{B}=80~\unicode[STIX]{x03BC}\text{m}$. A Gaussian envelope of the form (3.2) is applied, with $\unicode[STIX]{x1D70E}=3$, giving $B_{\text{rms},0}\approx 3~\text{kG}$. In all plots of two-dimensional vector fields, colour variations denote the value of the labelled quantity, while the white lines with directional arrows are streamlines of the plotted vector field. (a) Slice of perpendicular magnetic field taken along central perpendicular plane in configuration. (b) Path-integrated perpendicular magnetic field experienced by 3.3 MeV protons originating from a point source located at a distance $r_{i}=1~\text{cm}$ from the magnetic field configuration. This field was calculated numerically using test protons (see § P.3 for a description of this technique).

Figure 2

Figure 3.Characterisation of proton-flux images of stochastic magnetic fields by contrast regime. 3.3 MeV proton-flux images generated on an artificial detector at a distance $r_{s}=30~\text{cm}$ from magnetic-field configuration described in figure 2, for a range of magnetic field strengths (and hence values of $\unicode[STIX]{x1D707}$ (2.17)). The general arrangement of the imaging is the same as shown in figure 1. The proton point source was located at a distance $r_{i}=1~\text{cm}$ on the opposing side of the configuration to the detector, and $3\times 10^{7}$ protons were used per image. The procedure used to generate these images is described in § P.1. (a) Normalised proton-flux image in the linear regime, with $\unicode[STIX]{x1D707}\ll 1$ ($B_{\text{rms},0}\approx 3~\text{kG}$). (b) Effective image-coordinate grid arising from magnetic perturbations to initial Cartesian grid in the linear regime. (c) Normalised proton-flux image in the nonlinear injective regime, with $\unicode[STIX]{x1D707}<\unicode[STIX]{x1D707}_{c}\sim 1$ ($B_{\text{rms},0}\approx 30~\text{kG}$). (d) Image-coordinate grid in the nonlinear injective regime. (e) Normalised proton-flux image in the caustic regime, with $\unicode[STIX]{x1D707}\geqslant \unicode[STIX]{x1D707}_{c}$ ($B_{\text{rms},0}\approx 120~\text{kG}$). (f) Image-coordinate grid in the caustic regime. (g) Normalised proton-flux image in the diffusive regime, with $\unicode[STIX]{x1D707}\gtrsim 1/\unicode[STIX]{x1D6FF}\unicode[STIX]{x1D6FC}$ ($B_{\text{rms},0}=750~\text{MG}$). (h) Image-coordinate system in a diffusive regime.

Figure 3

Figure 4.Comparison of relative flux image predicted by diffusive model compared with actual result in diffusive regime. (a) The 3.3 MeV proton image-flux distribution associated with magnetic field described in figure 2, with $B_{\text{rms},0}=750~\text{kG}$. Here, relative flux refers to $\unicode[STIX]{x1D6FF}\unicode[STIX]{x1D6F9}(\boldsymbol{x}_{\bot }^{(s)})/\unicode[STIX]{x1D6F9}_{0}^{(s)}$, where $\unicode[STIX]{x1D6FF}\unicode[STIX]{x1D6F9}(\boldsymbol{x}_{\bot }^{(s)})\equiv \unicode[STIX]{x1D6F9}(\boldsymbol{x}_{\bot }^{(s)})-\unicode[STIX]{x1D6F9}_{0}^{(s)}$ is the flux deviation and $\unicode[STIX]{x1D6F9}_{0}^{(s)}$ the mean image flux. The same imaging parameters as those described in figure 4 are used (see figure 4g for normalised proton-flux image). (b) Predicted relative proton-flux image assuming uniform initial flux, and diffusive model of imaging-beam evolution (3.25), with $\unicode[STIX]{x1D6FF}=\unicode[STIX]{x1D6FF}(\boldsymbol{x}_{\bot })=\unicode[STIX]{x1D6FF}_{0}\exp [-4\unicode[STIX]{x1D70E}\boldsymbol{x}_{\bot }^{2}/l_{i}^{2}]$. Here, $\unicode[STIX]{x1D6FF}_{0}$ is given by (3.26), with $B_{\text{rms}}=750~\text{kG}$ and $l_{i}=l_{z}=l_{\bot }=0.1~\text{cm}$.

Figure 4

Figure 5.Efficacy of techniques for reconstructing magnetic field statistics directly from proton-flux images across contrast regimes. For each proton-flux image shown in figure 3, a reconstructed path-integrated magnetic field was produced by applying the field-reconstruction algorithm (see § P.4) appropriate for inverting the Monge–Ampère equation (3.19) with boundary conditions (3.20), before recovering the perpendicular-deflection field using (3.21), and finally the path-integrated field by (2.10). The true field is shown in figure 2(b). The magnetic-energy spectrum (true result shown in red) was predicted in two ways: using spectral relation (2.11) applied to the reconstructed perpendicular-deflection field (blue), and linear-regime spectral relation (3.15) applied directly to the proton-flux images (purple). (a) Path-integrated magnetic field reconstructed from linear-regime proton-flux image ($\unicode[STIX]{x1D707}\ll 1$), figure 3(a). (b) Predicted magnetic energy spectra, derived from figures 3(a) and 5(a). (c) Same as (a), but for nonlinear-injective-regime proton-flux image ($\unicode[STIX]{x1D707}<\unicode[STIX]{x1D707}_{c}$), figure 3(c). (d) Same as (b), but spectra derived from figures 3(c) and 5(c). (e) Same as (a), but for caustic-regime proton-flux image ($\unicode[STIX]{x1D707}\geqslant \unicode[STIX]{x1D707}_{c}$), figure 3(e). (f) Same as (b), but for figures 3(e) and 5(e). (g) Same as (a), but for diffusive-regime proton-flux image ($\unicode[STIX]{x1D707}\gtrsim 1/\unicode[STIX]{x1D6FF}\unicode[STIX]{x1D6FC}\gg 1$), figure 3(f). (h) Same as (b), but for figures 3(f) and 5(f).

Figure 5

Table 1.Comparison with true result of RMS magnetic-field strength predicted using magnetic-energy spectrum derived from (2.11) in different contrast regimes.

Figure 6

Figure 6.Illustration of ill posedness of reconstruction for spatially inhomogeneous stochastic magnetic fields. (a) Path-integrated perpendicular magnetic field associated with small-scale magnetic cocoon configuration (see § J.3) with correlation scale $l_{B}=0.8~\unicode[STIX]{x03BC}\text{m}$. A Gaussian envelope of the form (3.2) is applied to the magnetic field, with $\unicode[STIX]{x1D70E}=3$ and $B_{\text{rms},0}=2.2~\text{MG}$. (b) Path-integrated magnetic field associated with perpendicular-deflection field reconstructed from proton-flux image (c) generated from magnetic field described in (a), assuming an injective mapping. Typical proton deflection velocities in the central region are reduced by a factor ${\sim}25$. (c) 3.3-MeV proton-flux image created by imaging field configuration (a) with $3\times 10^{6}$ 15.0 MeV protons from point source located at $r_{i}=1~\text{cm}$ from the field configuration, and detector located on the opposing side, with $r_{s}=30~\text{cm}$. (d) Predicted 3.3-MeV proton-flux image, assuming proton beam with same imaging parameters as (c) experienced path-integrated magnetic field (b) while traversing the plasma.

Figure 7

Figure 7.Illustration of variation in $\unicode[STIX]{x1D707}$ across scales, with consequent discrepancy in structure size between path-integrated magnetic field, and proton-flux image. (a) Predicted path-integrated field for periodic stochastic Gaussian magnetic field specified on $1001^{2}$ array of spatial extent $l_{i}=l_{\bot }=l_{z}=0.1~\text{cm}$, with power-law spectrum of the form (4.8), spectral cutoffs $k_{l}=4\unicode[STIX]{x03C0}/l_{i}$, $k_{u}=800\unicode[STIX]{x03C0}/l_{i}$ and field RMS $B_{\text{rms}}=10~\text{kG}$. (b) Proton-flux image generated with 3.3 MeV protons from a point source at distance $r_{i}=1~\text{cm}$ from the array, with imaging detector at distance $r_{s}=30~\text{cm}$ on the opposite side.

Figure 8

Figure 8.Analysing proton-flux images of stochastic magnetic fields with broad magnetic-energy spectra. A stochastic magnetic field sample, with magnetic-energy spectrum of the form (4.8), is generated in a region, with dimensions $l_{i}=l_{z}=l_{\bot }=0.1~\text{cm}$. Field values are specified on a $301^{3}$ array (grid spacing $\unicode[STIX]{x1D6FF}x=l_{i}/301$). The spectral cutoffs were set to be $k_{l}=6\unicode[STIX]{x03C0}/l_{i}$, $k_{u}=2\unicode[STIX]{x03C0}/\unicode[STIX]{x1D6FF}x$, and $B_{\text{rms},0}=40~\text{kG}.$ A Gaussian envelope of the form (3.2) is again applied to the magnetic field, with $\unicode[STIX]{x1D70E}=3$. Imaging of the field is then implemented using the parameters given in figure 4. (a) Path-integrated perpendicular magnetic field as experienced by imaging 3.3 MeV protons. (b) The 3.3 MeV proton-flux image. (c) Path-integrated perpendicular magnetic field, with magnetic-field wavemodes whose wavenumber exceeds $k_{c}=30\unicode[STIX]{x03C0}/l_{i}$ removed. (d) The 3.3 MeV proton-flux image of filtered magnetic field. (e) Predicted path-integrated magnetic field found by applying field-reconstruction algorithm. (f) Magnetic-energy spectra: true result (red), plotted with prediction using deflection-field spectral relation (2.11) (blue) and linear-regime spectral relation (3.15) (purple).

Figure 9

Figure 9.Effect of initial flux inhomogeneity on well posedness of field-reconstruction algorithms. (a) Non-uniform initial 3.3 MeV proton image-flux distribution, with $\unicode[STIX]{x1D6F9}_{0}(\boldsymbol{x}_{\bot 0})=\unicode[STIX]{x1D6F9}_{0}/4(5{-}6x_{\bot 0}^{2}/l_{i}^{2})$. Imaging parameters of the set-up are the same as those described in figure 4. (b) Uniform initial flux distribution. (c) Path-integrated perpendicular magnetic field experienced by beam with initial flux distribution shown in (a). The magnetic field is the same as that described in figure 2, with $B_{\text{rms},0}=15~\text{kG}$. (d) Path-integrated perpendicular magnetic field experienced by initial flux distribution shown in (b). The magnetic field is constructed by applying the field-reconstruction algorithm to proton-flux image (c). (e)The 3.3 MeV proton-flux image resulting from initial flux distribution (a) experiencing path-integrated field (c). (f) The 3.3 MeV proton-flux image resulting from initial flux distribution (b) experiencing path-integrated field (d).

Figure 10

Figure 10.Distinguishing the nonlinear injective and caustic contrast regimes using nonlinear field-reconstruction algorithms and multiple beam energies. (a) 3.3 MeV proton-flux image of magnetic field described in figure 2, with $B_{\text{rms},0}=64~\text{kG}$, and same imaging parameters as those described in figure 3. (b) Same as (a), but with imaging beam composed of 15.0 MeV protons. (c) Same as (a), but now imaging implemented using a finite uniform spherical proton source with diameter $a=50~\unicode[STIX]{x03BC}\text{m}$. (d) Same as (c), but with imaging beam composed of 15.0 MeV protons. (e) Reconstructed path-integrated magnetic field obtained by applying the field-reconstruction algorithm (described in § 3.2) to (c). (f) Same as (e), but algorithm applied to (d). (g) Predicted 3.3 MeV proton-flux image, assuming imaging proton beam experienced reconstructed path-integrated field shown in (f) as a result of traversing magnetic field (the implementation is discussed in § P.3). Under the caustic detection scheme outlined in the main text, this image is to be compared with (c). (h) Predicted 15.0 MeV proton-flux image, assuming imaging proton beam experienced path-integrated field shown in (e). This image is to be compared with (d).

Figure 11

Figure 11.Effect of finite source size on successful extraction of magnetic-field statistics. (a) ‘Unsmeared’ 3.3 MeV proton-flux image created by imaging Golitsyn field, $B_{\text{rms},0}=30~\text{kG}$ (reproduction of figure 4c for convenience of reference). (b) Predicted path-integrated magnetic field resulting from application of field-reconstruction algorithm to figure (a). (c) ‘Smeared’ 3.3 MeV proton-flux image created by imaging same field as (a), but with a finite proton source, with diameter $a=50~\unicode[STIX]{x03BC}\text{m}$. (d) Same as (b), but with field-reconstruction algorithm applied to (c). (e) ‘De-smeared’ 3.3 MeV proton image subsequent to application of Richardson–Lucy algorithm for ten iterations. (f) Same as (b), but with field-reconstruction algorithm applied to (e). (g) Magnetic-energy spectra: true result (red), plotted with predictions using deflection-field spectral relation (2.11) applied to (b) (blue), (d) (green) and (f) (orange). (h) Ratio of predicted to actual RMS magnetic field strength for a range of field strengths using both linear-regime flux spectral relation (3.15) (dashed) and reconstructed deflection-field spectral relation (2.11) (solid), applied to unsmeared (blue), smeared (green) and de-smeared (orange).

Figure 12

Table 2.Glossary of notation.

Figure 13

Figure 12.Comparison of analytic theory of proton imaging with results from a numerical ray-tracing code for a compact magnetic field configuration. The magnetic field – generated using the technique described in § P.2 – is contained in a box, side length $l_{i}=l_{z}=l_{\bot }=0.1~\text{cm}$ and specified on a $201^{3}$ array (grid spacing $\unicode[STIX]{x1D6FF}x=l_{i}/201$); imaging is carried out using an artificial 3.3 MeV proton point source at distance $r_{i}=0.9~\text{cm}$ from the near side of the interaction region. These artificial test protons are propagated through the field using a ray-tracing code, and then to a detector located at $r_{s}=30~\text{cm}$. (a) Slice plot of magnetic-field configuration perpendicular to direction of beam throughout the interaction region (stretched in $z$-direction). The image colour denotes perpendicular magnetic-field strength, while the white arrows are the two-dimensional streamlines of the perpendicular magnetic field. (b) Numerically measured perpendicular-deflection field using the test protons. Image colour represents the magnitude of the perpendicular-deflection field, while arrows are (two-dimensional) streamlines. (c) Analytic prediction of perpendicular-deflection field (2.16). (d) Screen-flux distribution created numerically using $2\times 10^{6}$ test protons. (e) Prediction of image-flux distribution using analytic prediction (2.9), with same total proton flux.

Figure 14

Figure 13.Comparison of analytic prediction (4.11) with numerical result from a ray-tracing code of image-flux distribution generated by imaging the field configuration described in figure 12 using a finite proton source. As with figure 12, the detector is located at $r_{s}=30~\text{cm}$, leading to a $31\times$ magnification. (a) Image-flux distribution generated using $2\times 10^{6}$ test protons uniformly generated from a finite source, radius $a=0.005~\text{cm}$. (b) Analytic prediction of image-flux distribution using (4.11), with point-spread function given by (D 77), and image-flux distribution from point proton source shown in figure 12(e).

Figure 15

Figure 14.Geometry of a finite source, with required lengths and angles identified for determining the volume resulting from the intersection between a cone, opening angle $2\unicode[STIX]{x1D703}$, and the source, which in turns gives the probability-density function (PDF) of particle speeds at $\boldsymbol{x}_{\bot 0}$.

Figure 16

Figure 15.PDF of perpendicular radial speeds in the limit of small smearing for a proton beam created by a uniform, isotropically emitting sphere of radius $a=5\times 10^{-4}~\text{cm}$. The numerical PDF is calculated by generating $2\times 10^{7}$ 14.7 MeV particles inside the source, then propagating them a distance $r_{i}=1~\text{cm}$ to a box ‘interaction’ region, side length $l_{i}=0.1~\text{cm}$. For computational efficiency, angles are constrained so that polar angle $\unicode[STIX]{x1D703}\leqslant 1.1a/r_{i}$, and then the distribution of perpendicular particle speeds is sampled in a small region at the centre of the image of radius $\unicode[STIX]{x1D6FF}=5\times 10^{-5}~\text{cm}$ (the sample contained 41 000 particles).

Figure 17

Figure 16.Comparison of perpendicular-deflection fields and image-flux distributions resulting from a larger- and smaller-scale stochastic magnetic field. (a) Central slice plot of larger-scale stochastic magnetic field, located in interaction region, side length $l_{i}=l_{\bot }=l_{z}=0.1~\text{cm}$, perpendicular to direction of imaging proton beam. The field is specified on a $201^{3}$ array (grid spacing $\unicode[STIX]{x1D6FF}x=l_{i}/201$), with magnetic-energy spectrum of the form (G 3), $B_{\text{rms}}=10~\text{kG}$ and $l_{B}=170~\unicode[STIX]{x03BC}\text{m}$. (b) Equivalent slice plot of smaller-scale magnetic-field configuration, with same $B_{\text{rms}}$, but $l_{B}=30~\unicode[STIX]{x03BC}\text{m}$. (c) perpendicular-deflection field induced on 3.3 MeV proton beam by magnetic forces associated with larger-scale configuration as calculated using $3\times 10^{7}$ test protons from a point source, located at $r_{i}=1~\text{cm}$ from the array. (d) Deflection field induced on 3.3 MeV proton beam by magnetic forces associated with small-scale configuration. (e) Normalised image-flux distribution on detector ($r_{s}=30~\text{cm}$) resulting from imaging beam for larger-scale configuration. (f) Normalised image-flux distribution for smaller-scale field.

Figure 18

Figure 17.Numerical test of scaling laws for proton deflection angle $\unicode[STIX]{x1D6FF}\unicode[STIX]{x1D703}_{\text{rms}}$ and $\unicode[STIX]{x1D707}$. A range of stochastic magnetic fields of the same type to those described in figure 16 were generated, but with different correlation lengths $l_{B}$. The imaging procedure described in figure 16 was then applied to calculate the perpendicular-deflection field and image-flux distribution for each image. (a) Numerical calculation of perpendicular-deflection field RMS from tests (blue circles), plotted with prediction (G 5) (red). (b) Numerical calculation of relative image-flux deviation RMS from tests (blue), plotted with prediction (G 6) (red).

Figure 19

Figure 18.Validity of linear-regime prediction (I 28) of RMS relative image-flux variations for general $\unicode[STIX]{x1D707}$. For a particular instantiation of a cocoon configuration with correlation length $l_{B}=30~\unicode[STIX]{x03BC}\text{m}$ generated similarly to those fields described in figure 16, the RMS of magnetic-field strength $B_{\text{rms}}$ is varied; for each different value of $B_{\text{rms}}$, the same proton-imaging procedure outlined in figure 16 is carried out, and the associated RMS of relative image-flux deviations is calculated. This is compared to linear-regime prediction (I 1), with $\unicode[STIX]{x1D707}_{0}=3/2\sqrt{2\unicode[STIX]{x03C0}}\approx 0.6$.

Figure 20

Figure 19.Constructing two magnetic flux-rope structures with the same image-flux distribution. (a) Normalised magnetic flux-rope field (M 2), plotted with perturbed magnetic flux-rope constructed via a method described in § M.2; the specific perturbation is described by (M 29). (b) The $x$ coordinate of plasma-image mapping (M 8) for increasing $\unicode[STIX]{x1D707}$ (defined for the flux rope by (M 12)). (c) One-dimensional normalised image-flux distribution (M 13), for $\unicode[STIX]{x1D707}=4$. The two flux structures with large positive flux are caustics, and the region of proton flux between them has local contributions from spatially disconnected regions of the initial proton beam. The contributions of these different regions are indicated in the legend. (d) The $x$ coordinate of plasma-image mapping for $\unicode[STIX]{x1D707}=4$, along with mapping associated with perturbed magnetic flux rope.

Figure 21

Figure 20.Illustration of underdetermination of plasma-image mapping for known image-flux distribution. (a) One-dimensional normalised image-flux distribution (M 13), for $\unicode[STIX]{x1D707}=4$, focused on multivalued region. The dashed lines denote the contributions to the image-flux distribution from mappings $T_{1}$ (black), $T_{2}$ (blue) and $T_{3}$ (magenta) defined by (M 20), (M 21) and (M 22) respectively. (b) One-dimensional image-flux distribution focused on multivalued region for perturbed magnetic flux-rope field. The perturbation is defined by (M 29), combined with condition (M 24). The dashed lines denotes the contributions to the image-flux distribution from $S_{1}$ (black), $S_{2}$ (blue) and $T_{3}$ (magenta).

Figure 22

Figure 21.Accuracy of lower bound (N 2) for RMS deflection-field strength over increasing RMS magnetic-field strengths. Left: actual RMS deflection-field strength (black) associated with Golitsyn magnetic field configuration defined in figure 2 for a range of RMS magnetic-field strengths compared to predicted RMS deflection-field strength calculated from the perpendicular-deflection field reconstructed from numerically generated proton-flux images (red). The imaging parameters of the proton beam were identical to those used to create proton-flux images in figure 3, as was the implementation.

Figure 23

Figure 22.Diffusion of a pinhole beam through a strong, small-scale stochastic magnetic field. (a) Image-flux distribution created by pinhole beam of 3.3 MeV protons in the absence of magnetic fields, normalised by the maximum image-flux value. The pinhole beam contains $8\times 10^{5}$ 3.3 MeV protons, released from a point source at distance $r_{i}=1~\text{cm}$ from the $301^{3}$, $l_{i}=l_{z}=l_{\bot }=0.1~\text{cm}$ interaction region, and constrained to fall within the pinhole diameter $d_{pin}=0.02~\text{cm}$. The detector plane is located at $r_{s}=30~\text{cm}$ on the opposing side from the source. (b) Normalised image-flux distribution in the case of the beam passing through a magnetic field consisting of a random collection of ‘cocoons’, with $l_{B}=5.6~\unicode[STIX]{x03BC}\text{m}$, and $B_{\text{rms}}=2~\text{MG}$. The field was generated using the technique described in § P.2, while the artificial imaging procedure was carried out using the procedure given in § P.1. The normalisation factor in this case was the maximum value of the analytically predicted image-flux value. (c) Analytic prediction (3.25) of normalised image-flux distribution using isotropic diffusion model, with perpendicular-deflection-field RMS matching numerical field. (d) Lineouts along screen $x$-axis of numerically determined and analytically predicted image-flux distribution.

Figure 24

Figure 23.Diffusion of image-flux distribution associated with magnetic flux-rope structure due to strong small-scale fields. (a) Path-integrated magnetic field experienced by imaging proton beam (parameters identical to those used for the numerical experiment described in (O 41)) resulting from combination of a magnetic flux-rope field, maximum field strength $B_{\max }=110~\text{kG}$, with width $\unicode[STIX]{x1D6FF}=l_{i}/6$ and centre at $(x_{0},z_{0})=(-l_{i}/3,0)$, with statistically homogeneous small-scale field component consisting of magnetic cocoons with correlation length $l_{B}=8.3~\unicode[STIX]{x03BC}\text{m}$, and $B_{\text{rms}}=500~\text{kG}$. (b) 3.3 MeV normalised image-flux distribution in absence of small-scale fields obtained using numerical imaging scheme described in § P.1. (c) 3.3 MeV numerically determined normalised image-flux distribution including small-scale fields. (d) 3.3 MeV normalised image-flux distribution predicted by analytic relation (O 41) and adjusted to include correct level of Poisson noise given mean flux.

Figure 25

Figure 24.Example of high-resolution perpendicular-deflection fields and proton-flux image created using analytic theory of proton imaging. (a) The $4001^{2}$ perpendicular-deflection field predicted analytically using (2.11) for a stochastic magnetic field with power-law spectrum $E_{B}(k)\propto k^{-2}$, magnetic field strength RMS $B_{\text{rms}}=50~\text{kG}$, and spectral cutoffs $k_{l}=4\unicode[STIX]{x03C0}/l_{i}$, $k_{u}=4000\unicode[STIX]{x03C0}/l_{i}$. (b) The $4001^{2}$ proton-flux image generated by assigning $6.4\times 10^{9}$ synthetic 15.0 MeV protons with positions on the far side of the interaction region, and hence velocities as determined by the perpendicular-deflection field.