Hostname: page-component-74656f9884-6grmk Total loading time: 0 Render date: 2026-11-04T12:42:44.984Z Has data issue: false hasContentIssue false

Immunoglobulin concentration in bovine colostrum obtained by indirect methods

Published online by Cambridge University Press:  20 November 2025

Ingryd Muniz de Oliveira
Affiliation:
School of Veterinary Medicine and Animal Science, Universidade Federal de Mato Grosso do Sul, Campo Grande, MS, Brazil
Camila Soares Cunha
Affiliation:
School of Veterinary Medicine and Animal Science, Universidade Federal de Mato Grosso do Sul, Campo Grande, MS, Brazil
Luis Carlos Vinhas Ítavo
Affiliation:
School of Veterinary Medicine and Animal Science, Universidade Federal de Mato Grosso do Sul, Campo Grande, MS, Brazil
Luis Carlos Roma Júnior
Affiliation:
Agência Paulista de Tecnologia dos Agronegócios (APTA), Animal Science Institute, São Paulo, Brazil
Susana Amaral Teixeira
Affiliation:
School of Veterinary Medicine and Animal Science, Universidade Federal de Mato Grosso do Sul, Campo Grande, MS, Brazil
Geraldo Tadeu dos Santos*
Affiliation:
School of Veterinary Medicine and Animal Science, Universidade Federal de Mato Grosso do Sul, Campo Grande, MS, Brazil
*
Corresponding author: Geraldo Tadeu dos Santos; Email: gtsantos@uem.br
Rights & Permissions [Opens in a new window]

Abstract

The quality of colostrum is essential for the successful transfer of passive immunity and the early development of the immune system in newborns. This research was conducted with the aim of evaluating the agreement between measurements from different equipment: colostrometer, digital Brix refractometer and optical Brix refractometer, using fresh colostrum samples maintained at 21°C. Colostrum samples were collected from two farms (n1 = 31 and n2 = 193). Farm 1 included females from second to ninth lactation, comprising 15 Holstein Friesian (HF), 5 Jersey and 11 Holstein × Jersey crossbreeds. Farm 2 had HF heifers and cows from first to seventh lactation. Immunoglobulin content was assessed indirectly with a colostrometer and both types of Brix refractometers (digital and optical). For the correlation analysis, Pearson's product-moment method was used to assess the linear association between the equipment, followed by a Student's t-test and comparison of the obtained values with specific correlation coefficients (50%, 70%, 90% and 99%). There was a 98% correlation between the refractometers on Farm 1, which was significantly higher (P < 0.0001) than the commonly used reference values for weak (50%), moderate (70%) and strong (90%) correlations, and statistically equivalent to a 99% correlation. This indicates a very high, positive linear association between the digital and optical Brix refractometers. On Farm 2, a 97% correlation was found between the refractometers, which was significantly higher (P < 0.0001) than the specific reference values of 50%, 70% and 90%, but significantly lower than a 99% correlation.

Information

Type
Research Article
Copyright
© The Author(s), 2025. Published by Cambridge University Press on behalf of Hannah Dairy Research Foundation.
Figure 0

Figure 1. Distribution of Ig concentrations in the 224 bovine colostrum samples from both dairy farms (n1 = 31 and n2 = 193), evaluated using a colostrometer (A), digital Brix refractometer (B) and optical Brix refractometer (C).

Figure 1

Table 1. Descriptive statistics of colostrum samples from Farm 1, Farm 2 and total data showing measurements obtained by the colostrometer (Ig concentration, mg/mL), digital Brix refractometer (% Brix) and optical Brix refractometer (% Brix)

Figure 2

Table 2. Correlation coefficients among the equipment used to estimate the colostrum immunological quality

Figure 3

Table 3. Evaluation of the extent of pairwise Pearson correlation coefficients (ρ) between pairs of equipment

Figure 4

Table 4. Concordance coefficient for pairs of equipment considering total data (n = 224), Farm 1 (n = 31) and Farm 2 (n = 193)