Pre-procedural CT imaging aids neonatal PDA stenting for ductal-dependent pulmonary blood flow with reduction in overall procedural morbidity

Published online by Cambridge University Press:  19 October 2021

Yousef Arar*
Affiliation:
Department of Pediatrics, University of Texas Southwestern Medical Center, Dallas, Texas, USA Pediatric Cardiology, Children’s Medical Center, Dallas, Texas, USA
V. Vivian Dimas
Affiliation:
Department of Pediatrics, University of Texas Southwestern Medical Center, Dallas, Texas, USA Pediatric Cardiology, Children’s Medical Center, Dallas, Texas, USA
Alan W. Nugent
Affiliation:
Department of Pediatrics, Division of Pediatric Cardiology, Ann & Robert H. Lurie Children’s Hospital of Chicago, Chicago, Illinois, USA
Tarique Hussain
Affiliation:
Department of Pediatrics, University of Texas Southwestern Medical Center, Dallas, Texas, USA Pediatric Cardiology, Children’s Medical Center, Dallas, Texas, USA
Nima Kasraie
Affiliation:
Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
Surendranath R. Veeram Reddy
Affiliation:
Department of Pediatrics, University of Texas Southwestern Medical Center, Dallas, Texas, USA Pediatric Cardiology, Children’s Medical Center, Dallas, Texas, USA
Thomas M. Zellers
Affiliation:
Department of Pediatrics, University of Texas Southwestern Medical Center, Dallas, Texas, USA Pediatric Cardiology, Children’s Medical Center, Dallas, Texas, USA
Carrie Herbert
Affiliation:
Department of Pediatrics, University of Texas Southwestern Medical Center, Dallas, Texas, USA Pediatric Cardiology, Children’s Medical Center, Dallas, Texas, USA
*
Author for correspondence: Y. Arar, Pediatric Cardiology, Department of Pediatrics, UT Southwestern Children’s Medical Center, 1935 Medical District Drive, Dallas, TX 75235-7701, USA. Tel: +214 456 7311; Fax: +214 456 6154. E-mail: Yousef.Arar@UTSouthwestern.edu
Rights & Permissions [Opens in a new window]

Abstract

Patent ductus arteriosus stenting for ductal-dependent pulmonary blood flow is a technically challenging neonatal procedure to maintain a stable pulmonary circulation. Pre-procedural computed tomography imaging aids in outlining ductal origin, insertion, size, course and curvature. Computed tomography imaging may add value to procedural outcomes and reduce overall procedural morbidity in neonatal patent ductus arteriosus stenting. We conducted a single centre retrospective chart review of neonates with ductal-dependent pulmonary blood flow who underwent patent ductus arteriosus stenting between January 1, 2014 and June 31, 2020. We compared patients variables between patients who underwent pre-procedural computed tomography imaging to those who did not. A total of 64 patients were referred for patent ductus arteriosus stenting with 33 (52%) obtaining pre-procedural computed tomography imaging. Average age [19 days; range 1–242 days (p = 0.85)] and weight [3.3 kg (range 2.2–6.0 kg; p = 0.19)] was not significantly different between the groups. A diagnosis of pulmonary atresia was made in 42 out of 64 (66%) patients prior to patent ductus arteriosus stenting. The cohort with pre-intervention computed tomography imaging had a significant reduction in the total number of access sites (1.2 versus 1.5; p = 0.03), contrast needed (5.9 versus 8.2 ml/kg; p = 0.008), fluoroscopy (20.7 versus 38.8 minutes; p = 0.02) and procedural time (83.4–128.4 minutes; p = 0.002) for the intervention. There was no significant difference in radiation burden between the groups (p = 0.35). Pre-procedural computed tomography imaging adds value by aiding interventional planning for neonatal patent ductus arteriosus stenting. A statistically significant reduction in the number of access sites, contrast exposure, as well as fluoroscopic and procedural time was noted without significantly increasing the cumulative radiation burden.

Information

Type
Original Article
Copyright
© The Author(s), 2021. Published by Cambridge University Press
Figure 0

Figure 1. Case examples of the most common vascular access sites used for PDA stent deployment.

Figure 1

Table 1. Demographic and procedural data comparing the two groups of PDA-stented patients with and without pre-procedural cardiac CT imaging. There is a statistically significant reduction in the total number of access sites, contrast needed, fluoroscopic and procedural sheath time for the intervention

Figure 2

Table 2. Summary of access sites used for PDA stent deployment

Figure 3

Table 3. Summary of radiation burden comparing the two groups of PDA stented patients with and without pre-procedural cardiac CT imaging

Figure 4

Figure 2. Neonatal PDA stenting approach and procedure. (a) Pre-procedural cardiac CT 3D reconstruction showing a “corkscrew” PDA. (b) Patient was approached via the left axillary artery (LAA) to left subclavian artery (LSCA) for PDA stenting. (c) Successful delivery of a 3.5 mm × 23 mm Vision Multilink stent.

Figure 5

Figure 3. Neonate with discontinuous pulmonary arteries and bilateral PDAs. (a) Pre-procedural cardiac CT 3D reconstruction shows the left carotid artery (LCA) as the best approach to stent both PDAs via one access site. (b and c) Both PDAs are stented via the LCA. One stent [Xience 3.5 mm × 18 mm drug eluting stent (DES)] was placed in the left PDA and two stents were placed in the right PDA (Xience 3.5 mm × 18 mm DES × 1 and 3.5 mm × 8 mm Vision Multilink stent x1).

Figure 6

Figure 4. Series of images showing difficulties when stenting a tortuous PDA that does not straighten after traversing with a wire/stent. (a) Upper panel starts with a hand injection at the aortic end of the PDA from the femoral approach showing a type 3 PDA with a ductal tortuosity index (DTI) of approximately 400. The wire and stent would not advance from the femoral approach so a right carotid artery approach was attempted. Notice that the PDA did not straighten out and multiple stents (3.5 mm × 23, 14, 12, 12 mm Vision Multilink stents) were required to traverse the full length of the tortuous PDA. (b) Lower panel shows another example of a tortuous PDA unsuccessfully approached from the femoral artery (type 3; DTI ∼250). In this example, the patient was re-approached via the left axillary artery to the left subclavian artery (LSCA) and the PDA straightened out with wire and stent across. This delivery was made much simpilier because of the straightening of the PDA with only one long stent required (3.5 mm × 23 mm Vision Multilink). Orange line = Straight PDA length; White (solid) line = Actual PDA length; White (dashed) line = Ideal site of access for PDA stenting virtually represented on CT 3D reconstruction.

Figure 7

Figure 5. Neonate with an extremely tortuosity type 3 PDA with a ductal tortuosity index of approximately 450. Despite appropriate vascular access planning, the stent is not able to overcome the tortuosity of the PDA. This patient was referred for a modified Blalock−Taussig shunt directly from the catheterisation lab. Orange line = straight PDA length; white line = actual PDA length.