Hostname: page-component-74656f9884-g96k6 Total loading time: 0 Render date: 2026-11-10T13:35:13.883Z Has data issue: false hasContentIssue false

Recent results on high-β plasma confinement studies in the Gas Dynamic Trap

Published online by Cambridge University Press:  02 May 2024

Evgeniy A. Shmigelsky*
Affiliation:
Budker Institute of Nuclear Physics, Lavrentyev avenue 11, Novosibirsk 630090, Russia Novosibirsk State University, Pirogov street 1, Novosibirsk 630090, Russia
Andrej A. Lizunov
Affiliation:
Budker Institute of Nuclear Physics, Lavrentyev avenue 11, Novosibirsk 630090, Russia Novosibirsk State University, Pirogov street 1, Novosibirsk 630090, Russia
Andrey K. Meyster
Affiliation:
Budker Institute of Nuclear Physics, Lavrentyev avenue 11, Novosibirsk 630090, Russia
Egor I. Pinzhenin
Affiliation:
Budker Institute of Nuclear Physics, Lavrentyev avenue 11, Novosibirsk 630090, Russia
Alexander L. Solomakhin
Affiliation:
Budker Institute of Nuclear Physics, Lavrentyev avenue 11, Novosibirsk 630090, Russia Novosibirsk State University, Pirogov street 1, Novosibirsk 630090, Russia
Dmitry V. Yakovlev
Affiliation:
Budker Institute of Nuclear Physics, Lavrentyev avenue 11, Novosibirsk 630090, Russia University of Wisconsin-Madison, Madison, WI 53706, USA
*
†Email address for correspondence: e.shmigelskii@g.nsu.ru

Abstract

This paper is devoted to experimental studies of plasma confinement with high relative pressure ($\beta$) in the Gas Dynamic Trap (BINP, Novosibirsk). In previous high-$\beta$ confinement studies a maximum local $\beta = 0.6$ was achieved in the fast-ion turning point, contributed to by a beam-driven population of fast ions with an anisotropic distribution function. In this study the axial magnetic field profile was modified to bring the turning points closer to one another, which effectively increased the energy density of plasma and pushed the $\beta$ value higher. Experiments were performed for two non-standard magnetic configurations, where the axial fast-ion confinement region length was reduced by 1.5 and 2 times compared with the standard configuration. The average values of $\langle \beta _{\perp } \rangle$ over the plasma central cross-section were found to be 0.1 and 0.18, respectively, for the two configurations, with the latter value significantly exceeding the $\langle \beta _{\perp } \rangle =0.08$ of the standard configuration, in which the previous record was set. Moreover, halving the fast ion confinement region almost doubled the D–D fusion proton flux from the trap centre compared with the standard configuration. The electron temperature in both new magnetic configurations was only slightly smaller than in the standard configuration. In addition, an effect of Alfvén ion–cyclotron instability (AICI) development on the pressure in the turning points is discussed. Presumably, with some decrease in magnetic field an evolving AICI does not result in considerable pressure axial redistribution, so the pressure maximum is in the turning points’ vicinity despite the instability.

Information

Type
Research Article
Copyright
Copyright © The Author(s), 2024. Published by Cambridge University Press
Figure 0

Figure 1. (a) Layout of the GDT with its main parts and diagnostics: 1, arc plasma generator; 2, NBI; 3, secondary electron emission detector set; 4a, 4b, gas valves; 5a, 5b, annular limiters; 6a, 6b, 6c, diamagnetic loops; 7, dispersion interferometer's line of sight; 8, Thomson scattering system's line of sight; 9, proton detectors; 10, diagnostic plasma absorber; 11, azimuthal magnetic probe array. Blue and red arrows point out the coils involved in magnetic field profile modifications. (b) Axial profiles of magnetic field (left-hand axis) and $\beta _{\perp }$ calculated with the DOL code (right-hand axis) for the cases of various magnetic configurations denoted by parameter $\delta$.

Figure 1

Figure 2. Characteristic sequence of processes during plasma discharge in the example shot no. 52889 in configuration $\delta =1.5$. Time dependencies of (a) linear density $\langle n_{e}l\rangle$ and (b) diamagnetic fluxes $D$ measured in different planes along the trap axis defined by local mirror ratio values $R$. (c) Magnetic probe and (d) diamagnetic loop signal spectrograms demonstrate the presence of the AICI and the global sound mode, respectively. Radial profiles of the (e) electron temperature and (f) density at the end of NBI in the central GDT plane.

Figure 2

Figure 3. Comparison of two confinement regimes (moderate and enhanced gas puffing) in the $\delta =1.5$ configuration: (a) dependence of trapped NBI power on linear density, both averaged over NBI duration, and dependencies of (b) the maximum diamagnetism (in the central plane) and (c) its decay time after NBI on trapped NBI power. Comparison of confinement in magnetic configurations with $\delta =1$ and $\delta =1.5$: (d) dependence of maximum diamagnetism on trapped NBI power; radial (e) electron temperature and (f) density profiles.

Figure 3

Figure 4. Confinement regimes with standard ($B=0.33$ T) and low ($B=0.26$ T) magnetic field strengths in the $\delta =1.5$ configuration. Average (a) $\beta$ and (d) $\tau _{{\rm decay}}$ versus trapped NBI power. Radial (b) $T_{e}$ and (e) $n_{e}$ profiles. Time dependencies of diamagnetic flux at two planes denoted by the value of local mirror ratio $R$ and axial power losses in the case of (c) standard $B$ and (f) low $B$.

Figure 4

Figure 5. Average (a) $\beta _{\perp }$ and (c) $\tau _{{\rm decay}}$ for three magnetic configurations. Radial profiles of (b) $T_{e}$ and (d) $n_{e}$ for non-standard configurations with low $B$.

Figure 5

Figure 6. Time dependencies of (a–c) D–D proton and (d–f) diamagnetic fluxes in several plasma cross-sections (defined by local mirror ratio $R$) for configurations (a,d) $\delta =1$, (b,e) $\delta =1.5$ and (c,f) $\delta =2$. Panels (e,f) also show axial power losses on the right-hand axes.