A compact semi-lumped tunable complex-impedance transformer

Published online by Cambridge University Press:  08 September 2009

Anne-Laure Perrier*
Affiliation:
Laboratory of Microwaves and Characterization (LAHC), University of Savoie, 73376 Le Bourget-du-Lac, France. (Email: anne-laure.perrier@univ-lyon1.fr)
Jean-Marc Duchamp
Affiliation:
Institute of Microelectronics, Electromagnetism and Photonics (IMEP), UMR 5130 CNRS, INPG-UJF, BP 257, 38016 Grenoble Cedex 1, France. (Emails: duchamp@minatec.inpg.fr; philippe.ferrari@ujf-grenoble.fr; Olivier.Exshaw@grenoble.cnrs.fr)
Olivier Exshaw
Affiliation:
Institute of Microelectronics, Electromagnetism and Photonics (IMEP), UMR 5130 CNRS, INPG-UJF, BP 257, 38016 Grenoble Cedex 1, France. (Emails: duchamp@minatec.inpg.fr; philippe.ferrari@ujf-grenoble.fr; Olivier.Exshaw@grenoble.cnrs.fr)
Robert Harrison
Affiliation:
Department of Electronics, Carleton University, Ottawa K1S 5B6, Canada. (Email: rgh@doe.carleton.ca)
Philippe Ferrari
Affiliation:
Institute of Microelectronics, Electromagnetism and Photonics (IMEP), UMR 5130 CNRS, INPG-UJF, BP 257, 38016 Grenoble Cedex 1, France. (Emails: duchamp@minatec.inpg.fr; philippe.ferrari@ujf-grenoble.fr; Olivier.Exshaw@grenoble.cnrs.fr)
*
Corresponding author: Anne-Laure Perrier Email: anne-laure.perrier@univ-lyon1.fr
Rights & Permissions [Opens in a new window]

Abstract

This article describes the design and performance of a compact tunable impedance transformer. The structure is based on a transmission line loaded by varactor diodes. Using only two pairs of diodes, the circuit is very small with a total length of only λ/10. Both the frequency range and the load impedance can be tuned by varying the varactor bias voltages. Our design provides a tunable operating frequency range of ±40% and an impedance match ranging from 20 to 90 Ω at 0.8 GHz and from 30 to 170 Ω at 1.5 GHz. In addition, a new approach that considers losses for the simulation and measurement of this impedance transformer was investigated. The measured performance of a 1 GHz prototype design confirmed the validity of this new approach.

Information

Type
Original Article
Copyright
Copyright © Cambridge University Press and the European Microwave Association 2009
Figure 0

Table 1. Impedance transformers topology and performance.

Figure 1

Fig. 1. Equivalent electrical circuit of the impedance transformer.

Figure 2

Fig. 2. Equivalent circuits of one section of the impedance transformer.

Figure 3

Fig. 3. Simplified equivalent electrical circuit of the complex-impedance transformer.

Figure 4

Fig. 4. Principle of impedance transformations. The impedances (a) ZL1, (b) ZLC1, (c) ZL2, (d) ZLC2, and (e) Zout are synthesized at the transverse planes of the impedance transformer, as shown in Fig. 3.

Figure 5

Fig. 5. Equivalent circuit of the reverse-biased varactor diode.

Figure 6

Fig. 6. Synthesized impedances at (a) 0.5 GHz, (b) 1 GHz, and (c) 1.5 GHz.

Figure 7

Fig. 7. Total area of the synthesized impedances at (a) 0.5 GHz, (b) 1 GHz, and (c) 1.5 GHz.

Figure 8

Fig. 8. Experimental setup for the measurement of S11 and S21.

Figure 9

Fig. 9. Flowchart for the Mathematica simulation program.

Figure 10

Fig. 10. Complex loads generated by the program.

Figure 11

Fig. 11. Simulated coverage areas according to the “conjugate synthesized impedances (S22*)” approach (⚊) and the “matching loads” approach (•••), at 1 GHz without varactor's series resistance, i.e., lossless varactors.

Figure 12

Fig. 12. Simulated coverage areas at 1 GHz according to the “conjugate synthesized impedance” (S22*) method (⚊) and the “matching load” method (•••), when Rs = 1.6 Ω. Results are plotted for |S21|min values from −0.1 to −20 dB.

Figure 13

Fig. 13. Simulated 1 GHz coverage areas according to the “conjugate synthesized impedance” (S22*) method (⚊) and the “matching load” method (•••). Here the varactor series resistance Rs is varied.

Figure 14

Fig. 14. Simulated coverage areas according to the “conjugate synthesized impedance” (S22*) method (⚊) and the “matching load” method (•••), at (a) 1 GHz, and (b) 1.5 GHz for a 40°–15°–8° impedance transformer, with Rs = 1.6 Ω.

Figure 15

Fig. 15. Simulated coverage areas according to the “conjugate synthesized impedances” (S22*) method (⚊) and the “matching load” method (•••), at (a) 1 GHz, and (b) 1.5 GHz for a 40°–15°–8° impedance transformer, with Rs = 0.5 Ω.

Figure 16

Fig. 16. Photograph of the impedance transformer.

Figure 17

Fig. 17. Simulated (– –) and measured (—) frequency tuning ranges for a fixed 50-Ω load.

Figure 18

Fig. 18. Experimental setup for the measurement of S22.

Figure 19

Fig. 19. Simulated S22 values (⚊) compared with measured results (•••).

Figure 20

Fig. 20. Simulation results for the “matching loads” method with the criteria |S11| < −20 dB and |S21| > −2 dB versus frequency.

Figure 21

Fig. 21. Principle of the setups for the measurement of S11 and S21: (a) calibration planes, (b) load impedance measurement, and (c) measurement of S parameters.

Figure 22

Fig. 22. Measured matched complex loads, under the conditions −|S11| <−20 dB and |S21| > −2 dB, at three frequencies: (a) 0.8 GHz, (b) 1.0 GHz, and (c) 1.5 GHz. Simulations extracted from Fig. 20 in the same conditions: (d) 0.8 GHz, (e) 1.0 GHz, and (f) 1.5 GHz.

Figure 23

Fig. 23. Measured results for three different complex loads at 1 GHz, with the criteria |S11| < −20 dB and |S21| > −2 dB.

Figure 24

Fig. 24. Input impedance Zsin seen from Zin.

Figure 25

Fig. 25. Output impedance Zsout seen from Zout.