FINDS: an ImageJ script for rapid non-matrix diffraction spot identification in selected area electron diffraction patterns

Published online by Cambridge University Press:  16 October 2024

Thomas E. Weirich*
Affiliation:
Central Facility for Electron Microscopy (GFE), RWTH Aachen University, Aachen, Germany
*
a)Author to whom correspondence should be addressed. Electronic mail: weirich@gfe.rwth-aachen.de

Abstract

Phase characterization with selected area electron diffraction (SAED) represents a significant challenge when the pattern contains a substantial number of diffraction spots arranged in concentric but incomplete rings. This is a common situation when the crystallites are neither large enough to form a single crystal pattern nor sufficiently small and numerous to form continuous Debye-Scherrer rings. In such circumstances, it is often extremely difficult to distinguish between reflections belonging to a specific phase or to identify reflections that originate from secondary phases. To facilitate the process of phase identification for these kinds of multiphase samples, a macro script with the recursive acronym FINDS (FINDS Identifies Non-matrix Diffraction Spots) was developed on the ImageJ/FIJI platform. The program allows the user to mark diffraction spots of known phases by superimposed rings, making it easy to identify and address additional reflections between them. In addition to the full functionality of calculating and plotting the diffraction ring patterns of the known phases in different styles and colors, FINDS also provides tools for locating spot positions and determining the corresponding d-values of the reflections of interest. The effectiveness of this approach and of the developed program in assisting the process of phase identification with SAED patterns of multiphase samples is demonstrated by two representative examples. The macro code of FINDS is published under GNU General Public License v3.0 or later at https://doi.org/10.5281/zenodo.13748483.

Information

Type
Technical Article
Copyright
© The Author(s), 2024. Published by Cambridge University Press on behalf of International Centre for Diffraction Data
Figure 0

Figure 1. SAED patterns of the Cr–Fe spray coatings of samples A and B, as obtained from cross-sections prepared with a focused ion beam (FIB).

Figure 1

Figure 2. The FINDS start screen, where the format of the project file to be loaded in the next step is specified.

Figure 2

Figure 3. If both the X and Y centers of the SAED pattern have been set to zero in lines 3 and 4 of the project file, the diffraction pattern is displayed with a predefined circle which the user is asked to fit to one of the diffraction rings in the pattern. Note that a slight elliptical distortion of the diffraction ring can also be fitted by dragging the indicated anchor points of the ImageJ oval tool onto the reflection ring. The X and Y coordinates of the center of the diffraction pattern are obtained by the program from the center of the user-defined circle or ellipse.

Figure 3

Figure 4. FINDS main menu, which allows the user to make adjustments to the display of the processed SAED pattern. The “color mode” option can be used to change the default greyscale display to three different false colors and the “display mode” option allows the user to toggle between normal and inverted display of the diffraction pattern. The menu additionally allows the display of the simulated ring pattern to be toggled and to set different colors and line widths for drawing the superimposed rings. As low-angle diffraction spots are often most important for the identification of the phase, it is possible to focus on this part and to crop the SAED pattern by using the “d-value limit” option (see Figure 7 for an example).

Figure 4

Figure 5. For the SAED pattern of sample A, the manual mode was used to locate the positions of the diffraction spots by means of a crosshair cursor. For statistical reasons, several reflections were addressed for each diffraction ring (green crosses) and, after averaging of the d-values, were used to generate the superimposed rings on the SAED patterns in Figure 6.

Figure 5

Figure 6. SAED patterns of sample A (left) and sample B (right) with the superimposed ring pattern calculated from the experimental d-values obtained for sample A. The simulated ring positions are compatible with the bcc phase Fe3Cr (PDF card no. 04-022-2502) with refined lattice parameter a = 2.870(2) Å.

Figure 6

Figure 7. SAED pattern of sample B with the superimposed ring patterns of the bcc phase Fe3Cr (PDF card no. 04-022-2502) and the tetragonal phase Fe1.13Cr0.87 (PDF card no. 01-071-7531), respectively. The SAED patterns have been cropped to a resolution of 1.3 Å using the “d-value limit” option in the main menu (see Figure 4).

Figure 7

Figure 8. SAED pattern from a sample of magnetic iron oxide nanoparticles for biomedical applications. The diffraction pattern on the right is displayed in false color “mpl-magma” and has been cropped to a resolution of 1.0 Å. The superimposed rings correspond to the d-values of spinel-type Fe3O4 (PDF card no. 01-080-7683, a = 8.405 Å).

Figure 8

Figure 9. Magnified center section of the SAED pattern in Figure 8. The three weak diffraction spots that are indicated by the crosshair markers are not consistent with cubic spinel-type Fe3O4 and must therefore belong to a second phase. In order to obtain the most accurate d-values of these reflections, the ImageJ's built-in peak detection function “Find Maxima” was applied.