Hostname: page-component-7b7567c8c-tnkh4 Total loading time: 0 Render date: 2026-11-16T03:36:23.388Z Has data issue: false hasContentIssue false

Extension of a viscous thread with temperature-dependent viscosity and surface tension

Published online by Cambridge University Press:  14 July 2016

Dongdong He*
Affiliation:
School of Aerospace Engineering and Applied Mechanics, Tongji University, Shanghai 200092, China
Jonathan J. Wylie
Affiliation:
Department of Mathematics, City University of Hong Kong, Tat Chee Avenue, Hong KongCenter for Applied Mathematics and Statistics, New Jersey Institute of Technology, Newark, NJ 07102, USA
Huaxiong Huang
Affiliation:
Department of Mathematics and Statistics, York University, Toronto, ON M3J 1P3, CanadaFields Institute for Research in Mathematical Sciences, Toronto, ON M5T 3J1, CanadaCenter for Applied Mathematics and Statistics, New Jersey Institute of Technology, Newark, NJ 07102, USA
Robert M. Miura
Affiliation:
Department of Mathematical Sciences, New Jersey Institute of Technology, Newark, NJ 07102, USA
*
†Email address for correspondence: dongdonghe@tongji.edu.cn

Abstract

We consider the evolution of a long and thin vertically aligned axisymmetric viscous thread that is composed of an incompressible fluid. The thread is attached to a solid wall at its upper end, experiences gravity and is pulled at its lower end by a fixed force. As the thread evolves, it experiences either heating or cooling by its environment. The heating affects the evolution of the thread because both the viscosity and surface tension of the thread are assumed to be functions of the temperature. We develop a framework that can deal with threads that have arbitrary initial shape, are non-uniformly preheated and experience spatially non-uniform heating or cooling from the environment during the pulling process. When inertia is completely neglected and the temperature of the environment is spatially uniform, we obtain analytic solutions for an arbitrary initial shape and temperature profile. In addition, we determine the criteria for whether the cross-section of a given fluid element will ever become zero and hence determine the minimum stretching force that is required for pinching. We further show that the dynamics can be quite subtle and leads to surprising behaviour, such as non-monotonic behaviour in time and space. We also consider the effects of non-zero Reynolds number. If the temperature of the environment is spatially uniform, we show that the dynamics is subtly influenced by inertia and that the location at which the thread will pinch is selected by a competition between three distinct mechanisms. In particular, for a thread with initially uniform radius and a spatially uniform environment but with a non-uniform initial temperature profile, pinching can occur either at the hottest point, at the points near large thermal gradients or at the pulled end, depending on the Reynolds number. Finally, we show that similar results can be obtained for a thread with initially uniform radius and uniform temperature profile but exposed to a spatially non-uniform environment.

Information

Type
Papers
Copyright
© 2016 Cambridge University Press 
Figure 0

Figure 1.Vertical puller with external heater.

Figure 1

Figure 2.Cooling. (a) Evolution of cross-sectional area $A$ with different $\mathscr{F}^{\ast }$, (b) evolution of temperature ${\it\theta}$ with different $\mathscr{F}^{\ast }$. Parameters and conditions: $a=0.1$, $b=1$, $H=-1$, $\mathscr{H}=1$, $\mathscr{F}_{c}=2.6692$.

Figure 2

Figure 3.Heating. (a) Evolution of cross-sectional area $A$ with different $\mathscr{F}^{\ast }$, (b) evolution of temperature ${\it\theta}$ with different $\mathscr{F}^{\ast }$. Parameters and conditions: $a=0.1$, $b=1$, $H=1$, $\mathscr{H}=1$, $\mathscr{F}_{c}=0.8997$.

Figure 3

Figure 4.Results in Eulerian coordinates for heating with ${\it\theta}_{0}({\it\xi})=1$ and where $A_{0}({\it\xi})$ has a minimum point. (a) Evolution of cross-sectional area $A$, (b) evolution of temperature ${\it\theta}$. Parameters and conditions used: $a=0.1$, $b=1$, $H=1$, $\mathscr{H}=1$, $A_{0}({\it\xi})=0.5+2({\it\xi}-0.5)^{2}$, ${\it\theta}_{0}({\it\xi})=0$, $\mathscr{F}=0.645>\mathscr{F}_{c}({\it\xi}=0.5)$, $\mathit{Bo}=0$.

Figure 4

Figure 5.Results in Lagrangian coordinates for heating with ${\it\theta}_{0}({\it\xi})=1$ and where $A_{0}({\it\xi})$ has a minimum point. (a) Evolution of cross-sectional area $A$, (b) evolution of temperature ${\it\theta}$. Parameters and conditions used: $a=0.1$, $b=1$, $H=1$, $\mathscr{H}=1$, $A_{0}({\it\xi})=0.5+2({\it\xi}-0.5)^{2}$, ${\it\theta}_{0}({\it\xi})=0$, $\mathscr{F}=0.645>\mathscr{F}_{c}({\it\xi}=0.5)$, $\mathit{Bo}=0$. Note that the evolution of $A$ near ${\it\xi}=0.5$ is non-monotonic.

Figure 5

Figure 6.Results for heating when ${\it\theta}_{0}({\it\xi})$ has a local maximum and $A_{0}({\it\xi})=1$. (a) Evolution of cross-sectional area $A$, (b) evolution of temperature ${\it\theta}$. Parameters and conditions used: $a=0.1$, $b=1$, $H=1$, $\mathscr{H}=1$, $A_{0}({\it\xi})=1$, ${\it\theta}_{0}({\it\xi})=\exp (-({\it\xi}-0.5)^{2})$, $\mathscr{F}=0.84<\mathscr{F}_{c}({\it\xi}=0.5)$, $\mathit{Bo}=0$.

Figure 6

Figure 7.Results for cooling when ${\it\theta}_{0}({\it\xi})$ has a local maximum and $A_{0}({\it\xi})=1$. (a) Evolution of cross-sectional area $A$, (b) evolution of temperature ${\it\theta}$. Parameters and conditions used: $a=0.1$, $b=1$, $H=-1$, $\mathscr{H}=1$, $A_{0}({\it\xi})=1$, ${\it\theta}_{0}({\it\xi})=-({\it\xi}-0.5)^{2}$, $\mathscr{F}=3>\mathscr{F}_{c}({\it\xi}=0.5)$, $\mathit{Bo}=0$.

Figure 7

Figure 8.Numerical results for a thread with initially uniform radius and temperature subjected to spatially uniform heating. (a) Evolution of $A$. (b) Evolution of ${\it\theta}$. Parameters and conditions used: $a=0.1$, $b=1$, $A_{0}({\it\xi})=1$, ${\it\theta}_{0}({\it\xi})=0$, $\mathscr{F}=1.0005$, $\mathit{Re}=0.001$,$H=2-{\it\theta}$, $\mathscr{H}=1$, $\mathit{Bo}=0$.

Figure 8

Figure 9.Numerical results for a uniform thread whose initial temperature ${\it\theta}_{0}({\it\xi})$ is maximum at the upper boundary point ${\it\xi}=0$. (a,b) $\mathit{Re}=0.01$ (small $\mathit{Re}$), pinching happens at the hottest point, i.e. ${\it\xi}=0$. (c,d) $\mathit{Re}=10$ (relatively large $\mathit{Re}$), pinching happens at the pulled end. Parameters and conditions used: $a=0.1$, $b=1$, $A_{0}({\it\xi})=1$, ${\it\theta}_{0}({\it\xi})=2(1-{\it\xi}^{2})$, $\mathscr{F}=1.1$, $H({\it\theta})=-{\it\theta}$, $\mathscr{H}=1$, $\mathit{Bo}=0$.

Figure 9

Figure 10.Numerical results for a thread whose initial temperature ${\it\theta}_{0}({\it\xi})$ is two different constants near the two end points and has a rapid transition near ${\it\xi}=0.5$. (a,b) $\mathit{Re}=1$ (relatively small $\mathit{Re}$), pinching happens at the fluid element that initially had a large temperature gradient, i.e. ${\it\xi}=0.5$. (c,d) $\mathit{Re}=20$ (relatively large $\mathit{Re}$), pinching happens at the pulled end. Parameters and conditions used: $a=0.1$, $b=1$, $A_{0}({\it\xi})=1$, ${\it\theta}_{0}({\it\xi})=2(1+\tanh ((0.5-{\it\xi})/{\it\epsilon}))$, ${\it\epsilon}=0.04$, $\mathscr{F}=1.1$, $H({\it\theta})=-{\it\theta}$, $\mathscr{H}=1$, $\mathit{Bo}=0$.

Figure 10

Figure 11.Numerical results for a thread whose initial temperature ${\it\theta}_{0}({\it\xi})$ is maximum at the upper boundary point ${\it\xi}=0$ and has a rapid transition down to zero near ${\it\xi}=0.5$. (a,b) $\mathit{Re}=0.01$ (small $\mathit{Re}$), pinching happens at the hottest point, i.e. ${\it\xi}=0$. (c,d) $\mathit{Re}=1$ (intermediate $\mathit{Re}$), pinching happens for a fluid element that was initially near the large temperature gradient, i.e. ${\it\xi}=0.5$. (e,f) $\mathit{Re}=20$ (relatively large $\mathit{Re}$), pinching happens at the pulled end. Parameters and conditions used: $a=0.1$, $b=1$, $A_{0}({\it\xi})=1$, ${\it\theta}_{0}({\it\xi})=8/3(1-{\it\xi}^{2})(1+\tanh ((0.5-{\it\xi})/{\it\epsilon}))/2$, ${\it\epsilon}=0.01$, $\mathscr{F}=1.1$, $H({\it\theta})=-{\it\theta}$, $\mathscr{H}=1$, $\mathit{Bo}=0$.

Figure 11

Figure 12.Numerical results for a thread with initially uniform radius and uniform temperature but with spatially non-uniform heating, where the external heater temperature ${\it\theta}_{h}$ is maximum at the upper boundary $x=0$ and has a rapid transition to zero near $x=0.5$. (a,b) $\mathit{Re}=0.01$ (small $\mathit{Re}$), pinching happens at the hottest point, i.e. $x=0$. (c,d) $\mathit{Re}=10$ (moderately large $\mathit{Re}$), pinching happens for a fluid element that was initially near the large temperature gradient $x=0.5$. (e,f) $\mathit{Re}=100$ (large $\mathit{Re}$), pinching happens at the pulled end. Parameters and conditions used: $a=0.1$, $b=1$, $A_{0}({\it\xi})=1$, ${\it\theta}_{0}({\it\xi})=0$, $\mathscr{F}=1.05$, $H({\it\theta})=1.05(1-3x^{2})(1+\tanh ((0.5-x)/{\it\epsilon}))-{\it\theta}$, ${\it\epsilon}=0.04$, $\mathscr{H}=1$, $\mathit{Bo}=0$.

Figure 12

Figure 13.Numerical results for a thread falling under gravity with non-zero stretching force and initially uniform temperature. (a,b) $\mathit{Re}=0.1$ (small $\mathit{Re}$), pinching occurs at the top, i.e. ${\it\xi}=0$. (c,d) $\mathit{Re}=10$ (relatively large $\mathit{Re}$), pinching occurs at the pulled end, i.e. ${\it\xi}=1$. Parameters and conditions used: $a=0.1$, $b=1$, $A_{0}({\it\xi})=1$, ${\it\theta}_{0}({\it\xi})=0$, $\mathscr{F}=1.1$, $H({\it\theta})=3-{\it\theta}$, $\mathscr{H}=1$, $\mathit{Bo}=1$.

Figure 13

Figure 14.Numerical results for a thread falling under gravity with zero stretching force and non-uniform initial temperature, where the initial temperature ${\it\theta}_{0}({\it\xi})$ has a rapid transition near ${\it\xi}=0.5$. (a,b) $\mathit{Re}=1$ (small $\mathit{Re}$), pinching happens at the top end due to the weight of the thread. (c,d) $\mathit{Re}=100$ (large $\mathit{Re}$), pinching occurs at a fluid element that was initially near the large temperature gradient. Parameters and conditions used: $a=0.1$, $b=1$, $A_{0}({\it\xi})=1$, ${\it\theta}_{0}({\it\xi})=3(1+\tanh ((0.5-{\it\xi})/{\it\epsilon}))/2$, ${\it\epsilon}=0.005$, $\mathscr{F}=0$, $H({\it\theta})=-{\it\theta}$, $\mathscr{H}=1$, $\mathit{Bo}=0.5$.