Hostname: page-component-74656f9884-npj9w Total loading time: 0 Render date: 2026-11-10T16:42:00.614Z Has data issue: false hasContentIssue false

High-energy laser facility PHELIX at GSI: latest advances and extended capabilities

Published online by Cambridge University Press:  01 April 2024

Zs. Major*
Affiliation:
GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany Helmholtz-Institut Jena, Jena, Germany
U. Eisenbarth
Affiliation:
GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany
B. Zielbauer
Affiliation:
GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany
C. Brabetz
Affiliation:
GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany
J. B. Ohland
Affiliation:
GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany Laboratoire pour I’Utilisation des Lasers Intenses, Ecole Polytechnique, Palaiseau Cedex, France
Y. Zobus
Affiliation:
GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany
S. Roeder
Affiliation:
GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany Institut für angewandte Physik, Technische Universität Darmstadt, Darmstadt, Germany
D. Reemts
Affiliation:
GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany
S. Kunzer
Affiliation:
GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany
S. Götte
Affiliation:
GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany
D. Neidherr
Affiliation:
GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany
J. Hornung
Affiliation:
GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany
P. Kewes
Affiliation:
GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany
D. Schumacher
Affiliation:
GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany
D. Beck
Affiliation:
GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany
P. Hesselbach
Affiliation:
GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany Institut für angewandte Physik, Goethe-Universität Frankfurt, Frankfurt am Main, Germany
M. Malki
Affiliation:
GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany Institut für angewandte Physik, Technische Universität Darmstadt, Darmstadt, Germany
P. Neumayer
Affiliation:
GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany Institut für angewandte Physik, Goethe-Universität Frankfurt, Frankfurt am Main, Germany
K. Weyrich
Affiliation:
GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany
A. Tauschwitz
Affiliation:
GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany
V. Bagnoud
Affiliation:
GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany Helmholtz-Institut Jena, Jena, Germany Institut für angewandte Physik, Technische Universität Darmstadt, Darmstadt, Germany
*
Correspondence to: Zs. Major, GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstraße 1, 64289 Darmstadt, Germany. Email: z.slattery-major@gsi.de

Abstract

The high-energy/high-intensity laser facility PHELIX of the GSI Helmholtzzentrum für Schwerionenforschung in Darmstadt, Germany, has been in operation since 2008. Here, we review the current system performance, which is the result of continuous development and further improvement. Through its versatile frontend architecture, PHELIX can be operated in both long- and short-pulse modes, corresponding to ns-pulses with up to 1 kJ pulse energy and sub-ps, 200 J pulses, respectively. In the short-pulse mode, the excellent temporal contrast and the control over the wavefront make PHELIX an ideal driver for secondary sources of high-energy ions, neutrons, electrons and X-rays. The long-pulse mode is mainly used for plasma heating, which can then be probed by the heavy-ion beam of the linear accelerator of GSI. In addition, PHELIX can now be used to generate X-rays for studying exotic states of matter created by heavy-ion heating using the ion beam of the heavy-ion synchrotron of GSI.

Information

Type
Review
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (https://creativecommons.org/licenses/by/4.0), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2024. Published by Cambridge University Press in association with Chinese Laser Press
Figure 0

Figure 1 The location of the PHELIX building on the GSI campus allows for using both high-energy laser pulses and the heavy-ion beam in combination at the Z6 experimental area downstream of the linear accelerator section, the UNILAC and at HHT, downstream of the heavy-ion synchrotron SIS18.

Figure 1

Figure 2 Digital mock-up of the experimental hall (ESR hall) downstream of the SIS18 heavy-ion synchrotron, showing the PHELIX beamline (green/grey tube) as it traverses several experimental areas on its way to HHT. The total length of the beam transport is of the order of 65 m.

Figure 2

Figure 3 Schematic floor plan of PHELIX. The laser amplifier chain is situated in the PHELIX laser bay, together with the grating compressor and the petawatt target area (PTA) for the short, highest-intensity pulses. The PHELIX long pulse can be directed to the Z6 and HHT experiment areas, where it can be combined with the heavy-ion beams from UNILAC and SIS18, respectively. In addition, the Z6 area has the possibility to use the sub-aperture, short-pulse beam of PHELIX. This figure is based on the original version by Ohland[20] and its modification by Malki[21].

Figure 3

Table 1 PHELIX pulse parameters at the different experimental areas (central wavelength $\lambda$, maximum pulse energy ${E}_{\mathrm{max}}$, pulse duration $\tau$ and resulting maximum intensity ${I}_{\mathrm{max}}$). Laser pulses with these characteristics are available on target during routine operation and are somewhat lower than the maximum possible output of the system in order to allow for long-term, damage-free operation.

Figure 4

Figure 4 Build-up of wavefront aberrations in high-repetition-rate operation of the preamplifier. The peak-to-valley value of the wavefront distribution as a function of time is shown after the 45-mm preamplifier module with 45 s between laser shots, starting at 6 min. After about 20 min an equilibrium is reached, in which the aberrations remain constant over time. At 51 min (red dashed line) the aberrations, which mostly consist of defocus, are compensated by moving a lens in the Kepler telescope of the preamplifier setup.

Figure 5

Figure 5 Typical temporal pulse shape of the compressed PHELIX sub-ps pulse, measured with a high-dynamic-range third-order cross-correlator. On top of a very low ASE background limited by the noise of the measurement device, the peaks before the main pulse are mainly due to artifacts[30,31].

Figure 6

Figure 6 Layout of the petawatt target area sensor (top). The leakage of the last turning mirror before the target chamber is used to monitor the beam quality as close as possible to the laser–matter interaction experiment. A closed loop with a full-aperture deformable mirror allows for the maximization of the focused intensity on the target. The focal spots without (bottom left) and with (bottom right) this optimization loop are shown. Note that we quantify the spot quality in absolute terms of intensity instead of a relative Strehl ratio due to high-order spatial frequencies on the surface of the focusing optic, which is still to be characterized. This figure is reproduced from Ohland et al.[40] with the permission of the authors.

Figure 7

Figure 7 Example of the PCS graphical user interface. The different parts of the laser chain and diagnostics can be accessed on different tabs. In the picture the preamplifier stage is shown.

Figure 8

Figure 8 3D-model of the petawatt target area served by PHELIX. The target chamber has two entrance possibilities for the laser beam(s), which allows one to accommodate very diverse and highly complex experimental setups.

Figure 9

Figure 9 Photograph of the HHT experiment area downstream of the SIS18 heavy-ion synchrotron, showing the target chamber and the PHELIX beamline.

Figure 10

Figure 10 Second-harmonic generation in the PHELIX-HHT beamline showing the conversion efficiency at the HHTS. The inset shows a typical temporal shape of the PHELIX narrowband pulse.

Figure 11

Figure 11 Intensity distribution in the focal spot of the PHELIX beam at HHT area.

Figure 12

Figure 12 X-ray line-emission spectra from different mid-Z metal targets generated at HHT using the PHELIX ns-pulse.

Figure 13

Figure 13 Schematic representation of the timing signals used for synchronization of the SIS18 ion bunch to the PHELIX laser pulse.