A randomized trial of ultraviolet-C (UV-C) light versus sodium hypochlorite delivered by an electrostatic sprayer for adjunctive decontamination of hospital rooms

Published online by Cambridge University Press:  06 June 2022

Matthew G. Carlisle
Affiliation:
Research Service, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio
William A. Rutala
Affiliation:
Division of Infectious Diseases, University of North Carolina School of Medicine, Chapel Hill, North Carolina
Jennifer L. Cadnum
Affiliation:
Research Service, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio
Brigid M. Wilson
Affiliation:
Cleveland Clinic Foundation, Cleveland, Ohio
Abhishek Deshpande
Affiliation:
Center for Value-Based Care Research, Cleveland Clinic Lerner College of Medicine, Cleveland, Ohio
Curtis J. Donskey*
Affiliation:
Center for Value-Based Care Research, Cleveland Clinic Lerner College of Medicine, Cleveland, OhioCase Western Reserve University School of Medicine, Cleveland, Ohio
*
Author for correspondence: Curtis J. Donskey, MD, E-mail: Curtis.Donskey@va.gov
Rights & Permissions [Opens in a new window]

Abstract

In a randomized trial, adjunctive ultraviolet-C light treatment with a room decontamination device and sodium hypochlorite delivered via an electrostatic sprayer were similarly effective in significantly reducing residual healthcare-associated pathogen contamination on floors and high-touch surfaces after manual cleaning and disinfection. Less time until the room was ready to be occupied by another patient was required for electrostatic spraying.

Information

Type
Concise Communication
Creative Commons
This is a work of the US Government and is not subject to copyright protection within the United States. Published by Cambridge University Press on behalf of The Society for Healthcare Epidemiology of America.
Copyright
© Department of Veterans Affairs, 2022
Figure 0

Fig. 1.Percentages of rooms with positive cultures for 1 or more healthcare-associated pathogens before versus after treatment with the ultraviolet-C (UV-C) light device or the electrostatic sprayer. Note. HTS, high-touch surface.

Figure 1

Fig. 2.Colony-forming units (CFUs) recovered with Tukey boxplot overlay before versus after treatment with ultraviolet-C (UV-C) light or sodium hypochlorite applied with an electrostatic sprayer, both for a composite of all organisms (A) and for individual pathogens (B). The top and bottom of the boxes indicate the interquartile range (IQR) and the middle horizontal line the median. Whisker end points extend to last value within 1.5 times the IQR above the third quartile or below the first quartile. Note. C diff, Clostridioides difficile; VRE, vancomycin-resistant enterococci; and MRSA, methicillin-resistant Staphylococcus aureus.