Hostname: page-component-74656f9884-2dmjx Total loading time: 0 Render date: 2026-11-06T23:59:30.787Z Has data issue: false hasContentIssue false

Exploring sample size limits of AMS gas Ion Source 14C analysis at Cologneams

Published online by Cambridge University Press:  09 December 2019

Jan Olaf Melchert
Affiliation:
Institute of Geology and Mineralogy, University of Cologne, Zuelpicher Str. 49b, 50674 Cologne, Germany
Alexander Stolz
Affiliation:
Institute of Nuclear Physics, University of Cologne, Zuelpicher Str. 77, 50937 Cologne, Germany
Alfred Dewald
Affiliation:
Institute of Nuclear Physics, University of Cologne, Zuelpicher Str. 77, 50937 Cologne, Germany
Merle Gierga
Affiliation:
Institute of Geology and Mineralogy, University of Cologne, Zuelpicher Str. 49b, 50674 Cologne, Germany
Philipp Wischhöfer
Affiliation:
Institute of Geology and Mineralogy, University of Cologne, Zuelpicher Str. 49b, 50674 Cologne, Germany
Janet Rethemeyer*
Affiliation:
Institute of Geology and Mineralogy, University of Cologne, Zuelpicher Str. 49b, 50674 Cologne, Germany
*
*Corresponding author. Email: janet.rethemeyer@uni-koeln.de.
Rights & Permissions [Opens in a new window]

Abstract

Increasing demands for small-scale radiocarbon (14C) analyses required the installation of a “SO-110 B” type ion source (HVE Europa B.V.) at our 6 MV Tandetron AMS (HVE) dedicated for the direct injection of CO2 using either the gas injection system (GIS) from Ionplus AG or a EuroVector EA 3000 elemental analyzer (EA). We tested both systems with multiple series of 14C-free and modern standards (2.5–50 µg C) combusted in quartz ampoules or EA containers and were able to quantify exogenous C introduced. In EA-GIS-AMS analysis exogenous C is mainly derived from the EA sample containers. Blank values for 50 µg C combusted in solvent-cleaned tin (Sn) vessels were 0.0127 ± 0.0012 F14C (boats) and 0.0090 ± 0.0010 F14C (capsules), while they were much higher for thermally cleaned silver (Ag) capsules. The processing of gas samples for GIS-AMS yields similar blank values corresponding to 0.30 ± 0.08 µg exogenous C with 0.93 ± 0.23 F14C consisting of 0.28 µg C modern and 0.02 µg C fossil C. The combustion of larger amounts of blank material (1 mg C) in a single quartz tube split into aliquots gives lower blanks (0.0064 ± 0.0008 F14C; 50 µg C). Thus, 14C analysis of small, gaseous samples is now possible at CologneAMS.

Information

Type
Conference Paper
Copyright
© 2019 by the Arizona Board of Regents on behalf of the University of Arizona 
Figure 0

Figure 1 F14C vs. mass C [µg] measured by GIS-AMS: A) for 14C-free (POC#3) and B) modern (Ox-II) standard material (red circles). Fitting results are displayed as blue lines with 1-σ uncertainty (dashed blue lines). The fit assumes an error margin of 25%, outliers are displayed in black. C) shows the modelled solution space of χ² (indicated by colors) that depends on both contamination pools. The small circle indicates one possible solution for the fitting procedure as displayed by F14Cc and mc. D) displays the series of aliquots produced from one large sample, which has not been assessed using the χ² procedure, because only 14C-free standards have been prepared as aliquots.

Figure 1

Figure 2 Combined data set of A) 14C-free (POC#3) and B) modern (Ox-II) standard size series prepared in quartz ampoules for GIS-AMS analysis. Both sets have been corrected by the calculated contamination given in Figure1C and scatter around consensus values (solid black lines).

Figure 2

Figure 3 Overview of EA-GIS-AMS results for size series of blank material (POC#3) combusted in Sn boats (circle), Sn capsules (triangle), and in Ag capsules (square).

Figure 3

Table 1 Summary of blank assessment for 50 µg and 3.5 µg C large samples measured with GIS-AMS and EA-GIS-AMS analysis. The quantification is based on 14C-free standard material (POC#3) combusted in quartz ampoules (GIS) or in EA Sn containers using the Matlab script by Haghipour et al. (2019). We assume a similar F14C for GIS-AMS as determined for EA-GIS-AMS.

Supplementary material: File

Melchert et al. supplementary material

Table S1

Download Melchert et al. supplementary material(File)
File 35.3 KB