Hostname: page-component-74656f9884-8r8nv Total loading time: 0 Render date: 2026-11-10T11:29:07.137Z Has data issue: false hasContentIssue false

Comparison between mirror Langmuir probe and gas-puff imaging measurements of intermittent fluctuations in the Alcator C-Mod scrape-off layer

Published online by Cambridge University Press:  30 October 2020

R. Kube*
Affiliation:
Princeton Plasma Physics Laboratory, Princeton University, Princeton, NJ 08543-451, USA Department of Physics and Technology, UiT The Arctic University of Norway, N-9037 Tromsø, Norway
A. Theodorsen
Affiliation:
Department of Physics and Technology, UiT The Arctic University of Norway, N-9037 Tromsø, Norway
O. E. Garcia
Affiliation:
Department of Physics and Technology, UiT The Arctic University of Norway, N-9037 Tromsø, Norway
D. Brunner
Affiliation:
Commonwealth Fusion Systems, Cambridge, MA 02139, USA MIT Plasma Science and Fusion Center, Cambridge, MA 02139, USA
B. LaBombard
Affiliation:
MIT Plasma Science and Fusion Center, Cambridge, MA 02139, USA
J. L. Terry
Affiliation:
MIT Plasma Science and Fusion Center, Cambridge, MA 02139, USA
*
†Email address for correspondence: rkube@pppl.gov
Rights & Permissions [Opens in a new window]

Abstract

Statistical properties of the scrape-off layer plasma fluctuations are studied in ohmically heated plasmas in the Alcator C-Mod tokamak. For the first time, plasma fluctuations as well as parameters that describe the fluctuations are compared across measurements from a mirror Langmuir probe (MLP) and from gas-puff imaging (GPI) that sample the same plasma discharge. This comparison is complemented by an analysis of line emission time-series data, synthesized from the MLP electron density and temperature measurements. The fluctuations observed by the MLP and GPI typically display relative fluctuation amplitudes of order unity together with positively skewed and flattened probability density functions. Such data time series are well described by an established stochastic framework that models the data as a superposition of uncorrelated, two-sided exponential pulses. The most important parameter of the process is the intermittency parameter, $\gamma = {\tau _{d}} / {\tau _{w}}$, where ${\tau _{d}}$ denotes the duration time of a single pulse and ${\tau _{w}}$ gives the average waiting time between consecutive pulses. Here we show, using a new deconvolution method, that these parameters can be consistently estimated from different statistics of the data. We also show that the statistical properties of the data sampled by the MLP and GPI diagnostic are very similar. Finally, a synthetic GPI signal using only plasma parameters sampled by the MLP shows qualitatively different fluctuation statistics from the measured GPI signal.

Information

Type
Research Article
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright
Copyright © The Author(s), 2020. Published by Cambridge University Press
Figure 0

Table 1. List of the line-averaged core plasma density normalized to the Greenwald density, the average electron density and temperature at $\rho \approx 8\ \mathrm {mm}$, and the operational mode of the horizontal scanning probe.

Figure 1

Figure 1. A poloidal cross-section of Alcator C-Mod's outboard mid-plane region showing the LCFS (purple line), magnetic flux surfaces in the SOL (green lines), the views of the APDs (cyan dots, red dots show the diode views used in this study), the trajectory of the MLP when scanning (black arrow) and the position where the MLP dwells during discharge 3 (green dot).

Figure 2

Figure 2. Synthetic emission rate for the HeI $587\ \mathrm {nm}$ line as a function of the electron density and temperature. Overplotted are the average ${n_{e}}$ and ${T_{e}}$ values reported by the MLP at different $\rho$ positions in discharge 1 (black markers) and 2 (white markers). The error bars are given by the respective root-mean-square values.

Figure 3

Figure 3. Excerpt of original (as measured by the MLP) and reconstructed Te signals. The blue curve gives the original signal Te, the green dots indicate arrival times $t_k$ and normalized amplitudes for the pulses $A_k$ and the orange curve gives the reconstructed signal $D$. All signals are normalized so as to have zero mean and unit standard deviation.

Figure 4

Figure 4. Excerpt of original and reconstructed GPI signals at $R=91\ \text {cm}$. The blue curve gives the original signal $I_\mathrm {GPI}$, the green dots indicate arrival times $t_k$ and normalized amplitudes $A_k$ for the pulses and the orange curve gives the reconstructed signal $D$. All signals are normalized so as to have zero mean and unit standard deviation.

Figure 5

Figure 5. Radial profiles of various quantities sampled in discharge 1: (a) average; (b) relative fluctuation level; (c) skewness; (d) relative fluctuation level; and (e) intermittency parameter. The colour legend in (e) applies to all subplots.

Figure 6

Figure 6. Time series of ${n_{e}}$ (lowest panel), ${T_{e}}$ (middle panel) and synthetic GPI data (top panel) for discharge 1 (full line) and 2 (dashed line). Data are taken in the first interval where the probe scans from $\rho = 1.3$ to $1.2\ \mathrm {cm}$.

Figure 7

Figure 7. Histogram of $\tilde {n}_{e}$ (blue dots), $\tilde {T}_{e}$ (orange dots) and $\tilde {I}_\mathrm {syn}$ (purple dots) for discharge 1 (left) and 2 (right). Data are taken in all intervals where the probe scans from $\rho = 1.2$ to $1.3\ \mathrm {cm}$.

Figure 8

Figure 8. Left: PSD of the GPI data from two different radial positions measured in discharge 3 and (2.4) using parameters from a least-squares fit. Right: PSDs of the MLP signals and both (2.5) (red line) and (2.4) (black line) evaluated using parameters found from a least-squares fit.

Figure 9

Figure 9. PDFs of waiting times obtained from deconvolving the GPI and MLP time series. The synthetically generated time series is indicated by $\varPsi$. The black dotted line indicates exponential decay.

Figure 10

Figure 10. PDFs of the pulse amplitudes obtained from deconvolving the GPI and MLP time series. The synthetically generated time series is indicated by $\varPsi$.

Figure 11

Table 2. Process and pulse parameters estimated using MLP and GPI data sampled in discharge 3.

Figure 12

Figure 11. Full line: PSDs of MLP time series. Dotted line: Reconstructed time series from the RL deconvolution. The black dashed line gives the PSD predicted by (2.4) for the two-sided exponential pulse.