Hostname: page-component-74656f9884-npj9w Total loading time: 0 Render date: 2026-11-07T04:04:54.293Z Has data issue: false hasContentIssue false

Direct observation of particles with energy >10 MeV/u from laser-induced processes with energy gain in ultra-dense deuterium

Published online by Cambridge University Press:  24 September 2013

Leif Holmlid*
Affiliation:
Department of Chemistry and Molecular Biology, University of Gothenburg, Göteborg, Sweden
*
Address correspondence and reprint requests to: Leif Holmlid, Department of Chemistry and Molecular Biology, University of Gothenburg, SE-412 96 Göteborg, Sweden. E-mail holmlid@chem.gu.se

Abstract

Nuclear fusion in ultra-dense deuterium D(-1) was reported previously to be induced by 0.2 J pulses with 5 ns pulse length, ejecting particles with energies in the MeV range. The ns-resolved signal from D(-1) to two in-line collectors at up to 1 m distance can be observed directly on an oscilloscope, showing particles with energies in the range 1–20 MeV u−1. They are probably mainly protons and deuterons in the form of neutral ultra-dense hydrogen H(-1) fragments. Electrons and photons give only small contributions to the fast signal. The observed signal at several mA peak current corresponds to 1 × 1013 particles released per laser shot and to an energy release >4 J assuming isotropic formation and average particle energy of 3 MeV. This corresponds to an energy gain of 30 in the process. A movable slit close to the laser target gives lateral resolution of the signal generation, showing almost only fast particles from the point of laser impact and penetrating photons from the plasma outside the laser impact point. The observation of multi-MeV particles indicates nuclear fusion, either as a source or as a result.

Information

Type
Research Article
Copyright
Copyright © Cambridge University Press 2013 
Figure 0

Fig. 1. Horizontal cut through the apparatus, not to scale. The box in the central part is movable and has an entrance slit 3 mm wide at a distance of 74 mm from the target while the exit slit is much wider. The distance from the target to the inner collector is 64 cm, and to the outer collector 103 cm. Both collectors can be rotated out of the beam. The target-scintillator distance is 112 cm.

Figure 1

Fig. 2. (Color online) Signals to the inner collector with a 24 V battery in the cable to the 50 Ω oscilloscope input. Panel (a) is the signal when the collector is positive and attracts negative charges, while panel (b) shows the signal when the collector is negative and repels electrons, also those ejected from the collector by impact of heavier particles. The curves with the slit at maximum signal are shown, and the unmarked curves (black) are measured with the slit moved out from the beam. The times given are from the zero indicated. Cu laser target.

Figure 2

Fig. 3. (Color online) Two-collector measurements with –24 V collector bias. The directly measured signals are in the upper panel. In the lower panel the time-scale for the outer collector signal is recalculated by the ratio of the distances 64/103. Both original time-scales are also shifted by –5 ns to optimize the matching of the curves. Observe the small photon signal which does not shift as the particle signal. Ta target.

Figure 3

Fig. 4. (Color online) Two-collector measurements with zero collector bias. The directly measured signals are in the upper panel. In the lower panel the time-scale for the outer collector signal is recalculated by the ratio of the distances 64/103. Both original time-scales are also shifted by –5 ns to optimize the matching of the curves. Observe the small photon signal which does not behave as the particle signal. Ta target.

Figure 4

Fig. 5. Collector signals with –24 V bias on the collector as a function of the inner slit position. The angles to the right indicate the angle relative to the nominal maximum transmission position of the slit. The vertical lines indicate the start of the signal and the maxima. The arrows indicate the shift of the maximum at large angles with low transmitted signal. The stars indicate long slopes of the signals. Ni target.

Figure 5

Fig. 6. Collector signal with zero bias on the collector as a function of the inner slit position. The angles to the right indicate the angle. The vertical lines indicate the start of the signal and the maxima. Ta target.

Figure 6

Fig. 7. Collector signal with +24 V collector bias as a function of the inner slit position. The angles to the right indicate the angle relative to the nominal maximum transmission position of the slit. Ti target.

Figure 7

Fig. 8. TOF peaks in the scintillator-PMT detector with the beam-flag (the inner collector) in the beam (closed), at angles shown to give maximum transmission of the particle signal in Figure 5. Note that almost no particle signal passes undeflected through the collector at the central positions of the slit. Ni target.

Figure 8

Fig. 9. (Color online) TOF peaks in the scintillator-PMT detector signal at negative angles of the slit, thus mainly observing the plasma. Beam-flag (collector) position both closed and open (out from the beam). The signal is mainly due to photons which penetrate the beam-flag. A low-intensity delayed particle signal is also observed. Al target.

Figure 9

Fig. 10. Principle of the selection of flux to the detectors by the movable slit (box) at the target. In the position shown, particles from the point of laser impact have to penetrate the steel slit edge giving a delayed signal. Photons from the plasma are observed by the detectors on-line.