Hostname: page-component-6898cfcb55-zsp5v Total loading time: 0 Render date: 2026-11-11T08:20:57.116Z Has data issue: false hasContentIssue false

Estimation of transient heat transfer and fluid flow for alloy solidification in a rectangular cavity with an isothermal sidewall

Published online by Cambridge University Press:  14 August 2015

A. Plotkowski*
Affiliation:
Purdue Center for Metal Casting Research, School of Materials Engineering, Purdue University, West Lafayette, IN 47907, USA
K. Fezi
Affiliation:
Purdue Center for Metal Casting Research, School of Materials Engineering, Purdue University, West Lafayette, IN 47907, USA
M. J. M. Krane
Affiliation:
Purdue Center for Metal Casting Research, School of Materials Engineering, Purdue University, West Lafayette, IN 47907, USA
*
†Email address for correspondence: plotkoal@gmail.com

Abstract

Transient scaling and integral analyses were performed to predict trends in alloy solidification in a rectangular cavity cooled by an isothermal sidewall. The natural convection fluid flow was approximated by a scaling analysis for a laminar boundary layer at the solidification front, and was coupled to scaling and integral analyses of the energy equation to predict the solidification behaviour of the system. These analyses predicted several relevant aspects of the solidification process, including the time required to extinguish the initial superheat and the maximum local solidification time as a function of the system parameters and material properties. These results were verified by comparison to numerical simulations for an Al–4.5 wt% Cu alloy for various initial and boundary conditions and cavity aspect ratios. The analysis was compared to previous attempts to analyse similar fluid flow and solidification processes, and the limitations of the assumptions used for this analysis were discussed.

Information

Type
Papers
Copyright
© 2015 Cambridge University Press 
Figure 0

Figure 1.(a) A simplified binary alloy phase diagram and (b) the system schematic.

Figure 1

Figure 2.Numerical simulation of an Al–4.5 wt% Cu alloy in a 0.25 m square cavity initially at 1000 K and cooled from the left wall at 500 K, at times (a) $t=10$  s, (b) $t=30$  s, (c) $t=50$  s, (d) $t=70$  s, (e) $t=90$  s and (f) $t=110$  s. The contours are isotherms 5 K apart starting at the liquidus temperature and increasing to the right to the initial temperature.

Figure 2

Figure 3.Streamlines showing bulk fluid flow during solidification of an Al–4.5 wt% Cu alloy initially at 1000 K and cooled by the left isothermal wall at 500 K, at times (a) $t=10$  s, (b) $t=30$  s, (c) $t=50$  s, (d) $t=70$  s, (e) $t=90$  s and (f) $t=110$  s.

Figure 3

Figure 4.Assumed temperature profiles in the bulk liquid (a) before and (b) after the initial superheat has been consumed.

Figure 4

Figure 5.A schematic of the temperature profiles over the solid, mush, boundary layer and liquid regions used for the integral solution during (a) the first solidification regime and (b) the second.

Figure 5

Table 1.Property values for Al–4.5 wt% Cu alloy.

Figure 6

Figure 6.Grid dependence study on the base case given in table 2 showing changes in the time at which the system transitions between solidification regimes, $t_{m}(L)$, and the total solidification time, $t_{s2}(L)$. The central data points ($50\times 50$ cells on a square 0.25 m domain) was selected as the grid size for use in this study.

Figure 7

Table 2.Test matrix showing system variables for comparison of analyses to simulations.

Figure 8

Figure 7.Comparison of simulation results and scaling results for the location of the solidification front with time. The alloy system is Al–4.5 wt% Cu in a $0.25~\text{m}\times 0.25~\text{m}$ cavity and a wall temperature at 300 K. The simulation, initially at 1000 K, is compared to scaling results with constant superheat at the initial condition, and for scaling results with no superheat. The scaling results have been dilated such that $t_{m}(L)$ for the former case is approximately equal to the simulation time.

Figure 9

Figure 8.Comparison of liquidus position solution to simulation results over time for Al–4.5 wt% Cu alloy in 0.25 m square cavity, initially at 1000 K and cooled with a 300 K sidewall where the scaling results have been dilated so that $t_{m}(L)$ is equal to the simulation results. The integral analysis results have not been altered.

Figure 10

Figure 9.A comparison of $t_{m}(L)$ trends for scaling and integral analyses relative to the simulation results for (a) various wall temperatures and (b) various initial temperatures.

Figure 11

Figure 10.Comparison of simulation and integral analysis results for $t_{m}(L)$ as a function of (a) wall temperature and (b) initial temperature.

Figure 12

Figure 11.Comparison of trends for the scaling and integral analysis for $t_{s2}(L)$ relative to the simulation results for (a) various wall temperatures and (b) various initial temperatures.

Figure 13

Figure 12.Comparison of $t_{s}(L)$ between simulation and integral results as a function of (a) wall temperature and (b) initial temperature.

Figure 14

Figure 13.Comparison of trends in cool-down time with respect to the simulation results for both the scaling integral analyses for (a) various wall temperatures and (b) various initial temperatures.

Figure 15

Figure 14.A direct comparison between the integral analysis and the simulation results for the cool-down time as a function of (a) wall temperature and (b) initial temperature.

Figure 16

Figure 15.Local solidification time as a function of distance from the chill wall from a full numerical simulation of Al–4.5 wt% Cu in a 0.25 m square cavity, initially at 1000 K and cooled with an isothermal sidewall at 500 K. The vertical line shows the approximate thickness of the solid $({\it\delta}_{s})$ at the time when the liquid has been completely consumed $({\it\delta}=L)$.

Figure 17

Figure 16.A comparison of the simulation results for maximum local solidification time (a) to the trends predicted by the scaling and integral analyses and (b) directly to the integral analysis.

Figure 18

Figure 17.Simulation results for (a) $t_{m}(L)$, (b) $t_{s2}(L)$, (c) the cool-down time and (d) the maximum local solidification time as a function of aspect ratio.

Figure 19

Figure 18.Isotherms starting at the liquidus temperature and increasing to the right by 1 K for various aspect ratios, showing the change in the details of the temperature distribution in the liquid: (a) $A=3$, (b) $A=2$, (c) $A=1$, (d) $A=1/2$ and (e) $A=1/3$. Plots are made at 100 s into the process. The length of the cavity in the $x$ direction is 0.25 m for all cases.

Figure 20

Figure 19.Comparison of assumed temperature profiles in the liquid for (a) the study by Lin et al. (2007) and (b) this work.

Figure 21

Figure 20.Streamlines at various times for the test case in table 3: (a) $t=5$  s, (b) $t=15$  s, (c) $t=25$  s, (d) $t=35$  s, (e) $t=45$  s and (f) $t=55$  s.

Figure 22

Table 3.System parameters used for comparison to work by Lin et al.

Figure 23

Figure 21.Comparison of average bulk fluid temperature over time for the case in table 3 for simulation results, the present scaling analysis and the analyses performed by Lin et al. (2007) and Amberg (1997).

Figure 24

Figure 22.Comparison of progression of solidus and liquidus fronts with and without solutal effects for the base case in table 2.